'Bone map' for a safe placement of miniscrews generated by computed tomography

被引:26
|
作者
Hernandez, L. C. [1 ]
Montoto, G. [2 ]
Rodriguez, M. Puente [2 ]
Galban, L. [3 ]
Martines, V. [4 ]
机构
[1] Univ Oviedo, Dept Morphol & Cell Biol, Oviedo, Spain
[2] Univ Oviedo, Dept Orthodont, Oviedo, Spain
[3] Univ Salamanca, Dept Dent, E-37008 Salamanca, Spain
[4] Quiron Hosp, Madrid, Spain
关键词
anchorage; bone map; computed tomography; miniscrew; safe areas;
D O I
10.1111/j.1600-0501.2007.01507.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this manuscript is to provide a bone map that can be used as a general guide to determine the areas where miniscrews can be safely anchored. Materials and Methods: Twenty-one computed tomographies (CTs) of maxilla and mandible were taken by the imaging centre ORTOSCAN (R) and two measures were taken: -First, the interradicular space in the mesiodistal plane of the maxillary and mandible teeth with slices taken at 3, 6, and 9 mm from the alveolar crest, in the palatine and vestibular slices. -Second, the interradicular space in the vestibular-lingual direction. Results: We can see that the greatest amount of mesiodistal bone is between the first and second inferior molars on the vestibular side and between the second and first inferior molars on the lingual side, whereas the least amount of bone on the mesiodistal plane is between the inferior incisors on the vestibular side. To determine the length of the miniscrew, we must take into account that the greatest amount of vestibular-lingual bone is between the first and second inferior molar, whereas the least amount is between the central and lateral inferior incisors. Conclusions: Mesiodistal values in vestibular are those that must be considered when inserting the microscrew so as not to damage the dental tissue. Mesiodistal measurements taken in palatal-lingual do not present problems when inserting microscrews.
引用
收藏
页码:576 / 581
页数:6
相关论文
共 50 条
  • [1] Mapping occipital bone thickness using computed tomography for safe screw placement
    Morita, Tomonori
    Takebayashi, Tsuneo
    Takashima, Hiroyuki
    Yoshimoto, Mitsunori
    Ida, Kazunori
    Tanimoto, Katsumasa
    Ohnishi, Hirofumi
    Fujiwara, Hiroyoshi
    Nagae, Masateru
    Yamashita, Toshihiko
    JOURNAL OF NEUROSURGERY-SPINE, 2015, 23 (02) : 254 - 258
  • [2] Safe zones for miniscrews in maxillary dentition distalization assessed with cone-beam computed tomography
    Liu, Haibo
    Wu, Xiaoxue
    Yang, Lei
    Ding, Yin
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 151 (03) : 500 - 506
  • [3] A radiographic evaluation of the availability of bone for placement of miniscrews
    Schnelle, MA
    Beck, FM
    Jaynes, RM
    Huja, SS
    ANGLE ORTHODONTIST, 2004, 74 (06) : 832 - 837
  • [4] Measurement of cortical bone thickness in adults by cone-beam computerized tomography for orthodontic miniscrews placement
    Zhao, Hong
    Gu, Xiao-ming
    Liu, Hong-chen
    Wang, Zhao-wu
    Xun, Chun-lei
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2013, 33 (02) : 303 - 308
  • [5] Measurement of cortical bone thickness in adults by cone-beam computerized tomography for orthodontic miniscrews placement
    Hong Zhao
    Xiao-ming Gu
    Hong-chen Liu
    Zhao-wu Wang
    Chun-lei Xun
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2013, 33 : 303 - 308
  • [6] Measurement of Cortical Bone Thickness in Adults by Cone-beam Computerized Tomography for Orthodontic Miniscrews Placement
    赵弘
    顾晓明
    刘洪臣
    王照五
    寻春雷
    Journal of Huazhong University of Science and Technology(Medical Sciences), 2013, 33 (02) : 303 - 308
  • [7] Is Computed Tomography Safe?
    Smith-Bindman, Rebecca
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (01): : 1 - 4
  • [8] Safe zones of the maxillary alveolar bone in Down syndrome for orthodontic miniscrew placement assessed with cone-beam computed tomography
    Jacobo Limeres Posse
    María Teresa Abeleira Pazos
    María Fernández Casado
    Mercedes Outumuro Rial
    Pedro Diz Dios
    Márcio Diniz-Freitas
    Scientific Reports, 9
  • [9] Safe zones of the maxillary alveolar bone in Down syndrome for orthodontic miniscrew placement assessed with cone-beam computed tomography
    Limeres Posse, Jacobo
    Abeleira Pazos, Maria Teresa
    Fernandez Casado, Maria
    Outumuro Rial, Mercedes
    Diz Dios, Pedro
    Diniz-Freitas, Marcio
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [10] Anatomy of the ilium for bone marrow aspiration: map of sectors and implication for safe trocar placement
    Jacques Hernigou
    Alexandra Alves
    Yashiuro Homma
    Isaac Guissou
    Philippe Hernigou
    International Orthopaedics, 2014, 38 : 2585 - 2590