A practical approach to diode based in vivo dosimetry for intensity modulated radiotherapy

被引:13
|
作者
Kadesjo, Nils [1 ]
Nyholm, Tufye [1 ]
Olofsson, Jorgen [1 ]
机构
[1] Umea Univ, Dept Radiat Sci, Umea 90331, Sweden
关键词
IMRT; In vivo dosimetry; Diodes; Entrance dose; DOSE CALCULATIONS; QUALITY-INDEX; MODEL; SOFTWARE; ERRORS; OUTPUT;
D O I
10.1016/j.radonc.2010.12.018
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A method for in vivo entrance dosimetry, using point detectors, in intensity modulated radiotherapy has been clinically evaluated. Diode dosimetry was performed for treatments of the head and neck and prostate regions. The results were good; 92.2% of the measurements showed deviations within +/- 5% of the expected values. (C) 2011 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 98 (2011) 378-381
引用
收藏
页码:378 / 381
页数:4
相关论文
共 50 条
  • [1] In vivo diode dosimetry in standard and intensity modulated radiotherapy
    Marinello, G
    Mège, JP
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S15 - S15
  • [2] Implementation of in-vivo diode dosimetry for intensity modulated radiotherapy as routine patients' quality assurance
    AL-Shareef, Jamal M.
    Attalla, Ehab M.
    El-Gebaly, Reem H.
    Deiab, Nashaat A.
    Abdelmajeed, M.
    Fathy, Mohamed M.
    [J]. Radiation Physics and Chemistry, 2021, 187
  • [3] Implementation of in-vivo diode dosimetry for intensity modulated radiotherapy as routine patients' quality assurance
    AL-Shareef, Jamal M.
    Attalla, Ehab M.
    El-Gebaly, Reem H.
    Deiab, Nashaat A.
    Abdelmajeed, M.
    Fathy, Mohamed M.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2021, 187
  • [4] Dosimetric validation of new semiconductor diode dosimetry system for intensity modulated radiotherapy
    Kinhikar, Rajesh
    Chaudhari, Suresh
    Kadam, Sudarshan
    Dhote, Dipak
    Deshpande, Deepak
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2012, 8 (01) : 86 - 90
  • [5] Dosimetry of gated intensity modulated radiotherapy
    Solberg, TD
    Paul, TJ
    Agazaryan, NN
    Urmanita, T
    Arellano, AR
    Llacer, J
    Boone, RA
    Fog, R
    DeMarco, JJ
    Chetty, I
    Smathers, JB
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 286 - 288
  • [6] Practical guidelines for routine intensity-modulated radiotherapy verification: pre-treatment verification with portal dosimetry and treatment verification with in vivo dosimetry
    Vinall, A. J.
    Williams, A. J.
    Currie, V. E.
    Van Esch, A.
    Huyskens, D.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (995): : 949 - 957
  • [7] In Vivo Dosimetry of Conventional and Rotational Intensity Modulated Radiotherapy Using Integral Quality Monitor (IQM)
    Lin, L.
    Qian, J.
    Gonzales, R.
    Keck, J.
    Armour, E.
    Wong, J.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3445 - 3446
  • [8] Practical experience with intensity-modulated radiotherapy
    James, HV
    Scrase, CD
    Poynter, AJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (913): : 3 - 14
  • [9] Dosimetry of conformal dynamic arc radiotherapy and intensity modulated radiotherapy in unresectable cholangiocarcinoma
    Peerawong, Thanarpan
    Khorprasert, Chonlakiet
    Suriyapee, Sivalee
    Sanghangthum, Taweap
    Ayuthaya, Isra Israngkul Na
    Shotelersuk, Kanjana
    [J]. ASIAN BIOMEDICINE, 2010, 4 (01) : 131 - 139
  • [10] Radiochromic film based transit dosimetry for verification of dose delivery with intensity modulated radiotherapy
    Chung, Kwangzoo
    Yoon, Myonggeun
    Son, Jaeman
    Park, Sung Yong
    Lee, Kiho
    Shin, Dongho
    Lim, Young Kyung
    Lee, Se Byeong
    [J]. MEDICAL PHYSICS, 2013, 40 (02)