Practical guidelines for routine intensity-modulated radiotherapy verification: pre-treatment verification with portal dosimetry and treatment verification with in vivo dosimetry

被引:28
|
作者
Vinall, A. J. [1 ]
Williams, A. J. [1 ]
Currie, V. E. [1 ]
Van Esch, A. [2 ]
Huyskens, D. [2 ]
机构
[1] Norfolk & Norwich Univ Hosp NHS Fdn Trust, Radiotherapy Phys Dept, Norwich NR4 7UY, Norfolk, England
[2] 7 Sigma Nv, B-3150 Tildonk, Belgium
来源
BRITISH JOURNAL OF RADIOLOGY | 2010年 / 83卷 / 995期
关键词
RADIATION-THERAPY; DOSE DISTRIBUTIONS; IMRT VERIFICATION; QUALITY-ASSURANCE; EPID DOSIMETRY; IMAGING DEVICE; CLINICAL IMPLEMENTATION; QUANTITATIVE-EVALUATION; GEL DOSIMETRY; DIODE-ARRAY;
D O I
10.1259/bjr/31573847
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work is to provide guidelines for the routine use of portal dosimetry and in vivo diode measurements to verify intensity-modulated radiotherapy (IMRT) treatments. To achieve tolerance levels that are sensitive enough to intercept problems, both the portal dosimetry and the in vivo procedure must be optimised. Portal dosimetry was improved by the introduction of an optimised two-dimensional (2D) profile correction, which also accounted for the effect of backscatter from the R-arm. The scaled score, indicating the fraction of points not meeting the desired gamma evaluation criteria within the field opening, was determined as the parameter of interest. Using gamma criteria of a 3% dose difference and 3 mm distance to agreement, a "scaled score'' threshold value of 1.5% was chosen to indicate excessive tongue and groove and other problems. The pre-treatment portal dosimetry quality assurance (QA) does not encompass verification of the patient dose calculation or position, and so it is complemented by in vivo diode measurements. Diode positioning is crucial in IMRT, and so we describe a method for diode positioning at any suitable point. We achieved 95% of IMRT field measurements within +/- 5% and 99% within +/- 8%, with improved accuracy being achieved over time owing to better positioning. Although the careful preparation and setup of the diode measurements can be time-consuming, this is compensated for by the time efficiency of the optimised procedure. Both methods are now easily absorbed into the routine work of the department.
引用
收藏
页码:949 / 957
页数:9
相关论文
共 50 条
  • [1] Pre-treatment verification of intensity modulated beams using portal dosimetry
    Litoborski, M.
    Lipinska, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S212 - S212
  • [2] Implementation and validation of a commercial portal dosimetry software for intensity-modulated radiation therapy pre-treatment verification
    Varatharaj, C.
    Moretti, Eugenia
    Ravikumar, M.
    Malisan, Maria Rosa
    Supe, Sanjay S.
    Padovani, Renato
    [J]. JOURNAL OF MEDICAL PHYSICS, 2010, 35 (04) : 189 - 196
  • [3] IN VIVO DOSIMETRY AS SUBSTITUTE FOR PRE-TREATMENT VERIFICATION
    Mijnheer, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S191 - S191
  • [4] PRE-TREATMENT VERIFICATION OF INTENSITY MODULATED BEAMS USING TRANSIT DOSIMETRY
    Litoborski, M.
    Litoborska, J.
    Licznerska, E.
    Adamczyk, S.
    Kruszyna, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S390 - S390
  • [5] Uncertainty estimation in intensity-modulated radiotherapy absolute dosimetry verification
    Sanchez-Doblado, Francisco
    Hartmann, Gunther H.
    Pena, Javier
    Capote, Roberto
    Paiusco, Marta
    Rhein, Bernhard
    Leal, Antonio
    Lagares, Juan Ignacio
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (01): : 301 - 310
  • [6] 3D Portal Dosimetry for extreme hypofraction: pre-treatment and in vivo verification
    Pereira, M.
    Stroom, J.
    Rocha, A.
    Greco, C.
    Nijsten, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S724 - S726
  • [7] Pre-treatment verification of intensity modulated radiation therapy plans using a commercial electronic portal dosimetry system
    Roxby, Kathleen J.
    Crosbie, Jeffrey C.
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2010, 33 (01) : 51 - 57
  • [8] Pre-treatment verification of intensity modulated radiation therapy plans using a commercial electronic portal dosimetry system
    Kathleen J. Roxby
    Jeffrey C. Crosbie
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2010, 33 : 51 - 57
  • [9] From pre-treatment verification towards in-vivo dosimetry in TomoTherapy
    Santos, T.
    Ventura, T.
    Mateus, J.
    Capela, M.
    Lopes, M. D. C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S962 - S962
  • [10] Portal dosimetry verification of stereotactic intensity modulated fields
    Calvo Ortega, J.
    Moragues, S.
    Delgado, D.
    Pozo, M.
    Casals, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S767 - S767