Practical guidelines for routine intensity-modulated radiotherapy verification: pre-treatment verification with portal dosimetry and treatment verification with in vivo dosimetry

被引:28
|
作者
Vinall, A. J. [1 ]
Williams, A. J. [1 ]
Currie, V. E. [1 ]
Van Esch, A. [2 ]
Huyskens, D. [2 ]
机构
[1] Norfolk & Norwich Univ Hosp NHS Fdn Trust, Radiotherapy Phys Dept, Norwich NR4 7UY, Norfolk, England
[2] 7 Sigma Nv, B-3150 Tildonk, Belgium
来源
BRITISH JOURNAL OF RADIOLOGY | 2010年 / 83卷 / 995期
关键词
RADIATION-THERAPY; DOSE DISTRIBUTIONS; IMRT VERIFICATION; QUALITY-ASSURANCE; EPID DOSIMETRY; IMAGING DEVICE; CLINICAL IMPLEMENTATION; QUANTITATIVE-EVALUATION; GEL DOSIMETRY; DIODE-ARRAY;
D O I
10.1259/bjr/31573847
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this work is to provide guidelines for the routine use of portal dosimetry and in vivo diode measurements to verify intensity-modulated radiotherapy (IMRT) treatments. To achieve tolerance levels that are sensitive enough to intercept problems, both the portal dosimetry and the in vivo procedure must be optimised. Portal dosimetry was improved by the introduction of an optimised two-dimensional (2D) profile correction, which also accounted for the effect of backscatter from the R-arm. The scaled score, indicating the fraction of points not meeting the desired gamma evaluation criteria within the field opening, was determined as the parameter of interest. Using gamma criteria of a 3% dose difference and 3 mm distance to agreement, a "scaled score'' threshold value of 1.5% was chosen to indicate excessive tongue and groove and other problems. The pre-treatment portal dosimetry quality assurance (QA) does not encompass verification of the patient dose calculation or position, and so it is complemented by in vivo diode measurements. Diode positioning is crucial in IMRT, and so we describe a method for diode positioning at any suitable point. We achieved 95% of IMRT field measurements within +/- 5% and 99% within +/- 8%, with improved accuracy being achieved over time owing to better positioning. Although the careful preparation and setup of the diode measurements can be time-consuming, this is compensated for by the time efficiency of the optimised procedure. Both methods are now easily absorbed into the routine work of the department.
引用
收藏
页码:949 / 957
页数:9
相关论文
共 50 条
  • [21] An attenuation integral digital imaging technique for the treatment portal verification of conventional and intensity-modulated radiotherapy
    Guan, Huaiqun
    [J]. MEDICAL PHYSICS, 2010, 37 (07) : 3738 - 3743
  • [22] Validation and application of polymer gel dosimetry for the dose verification of an intensity-modulated arc therapy (IMAT) treatment
    Vergote, K
    De Deene, Y
    Duthoy, W
    De Gersem, W
    De Neve, W
    Achten, E
    De Wagter, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02): : 287 - 305
  • [23] Comparative study of three pre-treatment verification methods: Portal Dosimetry, Delta4 and Epiqa
    Maroote, J.
    Derdouri, A.
    Coutte, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S704 - S705
  • [24] Comparison of time-benefit ratio between in vivo dosimetry and pre-treatment verification in IMRT breast treatment
    Bermejo, S.
    Ventosa, N.
    Domenech, X.
    Flores, R.
    De Segura, G. Gomez
    Jimenez, J.
    Nolla, X.
    Martin, L. San
    Carrasco, P.
    Latorre, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S898 - S899
  • [25] Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification
    McDermott, L. N.
    Wendling, M.
    van Asselen, B.
    Stroom, J.
    Sonke, J. -J.
    van Herk, M.
    Mijnheer, B. J.
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3921 - 3930
  • [26] A pre-treatment verification method for intensity-modulated photon beams using VERO machine EPID
    Frigerio, M.
    Bonfanti, P.
    Ostinelli, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S849 - S850
  • [27] Gel-layer dosimetry for dose verification in intensity-modulated radiation therapy
    Tomatis, S.
    Carrara, M.
    Gambarini, G.
    Marchesini, R.
    Valente, M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 506 - 509
  • [28] Verification of treatment parameter transfer by means of electronic portal dosimetry
    Nijsten, S
    Minken, A
    Lambin, P
    Bruinvis, I
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1472 - 1472
  • [29] Verification of treatment parameter transfer by means of electronic portal dosimetry
    Nijsten, SMJJG
    Minken, AWH
    Lambin, P
    Bruinvis, IAD
    [J]. MEDICAL PHYSICS, 2004, 31 (02) : 341 - 347
  • [30] Evaluation of An Automated Treatment Planning Verification System for Intensity-Modulated Radiotherapy Treatment Planning
    Xiao, L.
    Yin, Y.
    Tong, L. Xiu
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2897 - 2897