An educational tool for demonstrating the TOF-PET technique

被引:5
|
作者
Bäck, T
Cederkäll, J
Cederwall, B
Johnson, A
Kerek, A
Klamra, W
van der Marel, J
Molnár, J
Novák, D
Sohler, D
Steèn, M
Uhlèn, P
机构
[1] Royal Inst Technol, Phys Dept Frescati, S-10405 Stockholm, Sweden
[2] Inst Nucl Res, ATOMKI, H-4001 Debrecen, Hungary
关键词
PET; TOF-PET; medical imaging;
D O I
10.1016/S0168-9002(01)00965-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A detector system for positron emission tomography with time-of-flight capability has been built to serve as an educational tool for undergraduate students. The set-up consists of 48 BaF2 scintillator crystals, each coupled to a fast photo-multiplier tube, mounted in a circular geometry. The analogue detector pulses are handled by fast constant fraction discriminators. A dedicated unit reduces the 48 channels to eight channels via delay-fine encoding, and the signals are then fed to an eight channel fast time-to-digital converter. A VME processor sorts the events and sends them to a workstation where the coincident events are extracted. The time resolution of the detectors together with fast VME based electronics allows for time-of-flight measurements to improve on the signal-to-noise ratio in the, reconstructed images. The system can be used for different types of exercises for the students, varying from the fundamentals of scintillator detectors to advanced image reconstruction. The set-up is described and some results are presented. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:200 / 204
页数:5
相关论文
共 50 条
  • [21] Measurement on properties of MPPC for TOF-PET system
    Yamazaki, M.
    Takeshita, T.
    Hasegawa, Y.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [22] Data driven time alignment for TOF-PET
    Rezaei, Ahmadreza
    Schramm, Georg
    Van Laere, Koenraad
    Nuyts, Johan
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [23] Development of TOF-PET using cherenkov radiation
    Miyata, Manabu
    Tomita, Hideki
    Watanabe, Kenichi
    Kawarabayashi, Jun
    Iguchi, Tetsuo
    J Nucl Sci Technol, 4 (339-343):
  • [24] Evaluation of the performance limit of MPPC for ToF-PET
    Tsujikawa, Takayuki
    Kataoka, Jun
    Ambe, Takahiro
    Fujita, Takuya
    Kurei, Yota
    Sato, Goro
    Ikeda, Hirolazu
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [25] Clinical Evaluation of PET Image Quality as a Function of Acquisition Time in a New TOF-PET/MRI Compared to TOF-PET/CT-Initial Results
    Zeimpekis, Konstantinos G.
    Barbosa, Felipe
    Huellner, Martin
    ter Voert, Edwin
    Davison, Helen
    Veit-Haibach, Patrick
    Delso, Gaspar
    MOLECULAR IMAGING AND BIOLOGY, 2015, 17 (05) : 735 - 744
  • [26] TOF-PET detector concept based on organic scintillators
    Moskal, Pawel
    Bednarski, Tomasz
    Bialas, Piotr
    Ciszewska, Marta
    Czerwinski, Eryk
    Heczko, Andrzej
    Kajetanowicz, Marcin
    Kaplon, Lukasz
    Kochanowski, Andrzej
    Konopka-Cupial, Gabriela
    Korcyl, Grzegorz
    Krzemien, Wojciech
    Lojek, Konrad
    Majewski, Jerzy
    Migdal, Wojciech
    Molenda, Marcin
    Niedzwiecki, Szymon
    Palka, Marek
    Rudy, Zbigniew
    Salabura, Piotr
    Silarski, Michal
    Slomski, Artur
    Smyrski, Jerzy
    Zdebik, Jaroslaw
    Zielinski, Marcin
    NUCLEAR MEDICINE REVIEW, 2012, 15 : C81 - C84
  • [27] Towards 50 ps TOF-PET for Brain imaging
    Harmon, Eric S.
    Thompson, Michael O.
    Schmidtlein, C. Ross
    Turner, James N.
    Krol, Andrzej
    MEDICAL IMAGING 2019: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2019, 10953
  • [28] TOF-PET/MR和TOF-PET/CT在体部恶性肿瘤SUV值的比较
    宋天彬
    卢洁
    崔碧霄
    马杰
    杨宏伟
    马蕾
    梁志刚
    中国医学影像技术, 2017, 33 (09) : 1401 - 1406
  • [29] Strip-PET: a novel detector concept for the TOF-PET scanner
    Moskal, Pawel
    Bednarski, Tomasz
    Bialas, Piotr
    Ciszewska, Marta
    Czerwinski, Eryk
    Heczko, Andrzej
    Kajetanowicz, Marcin
    Kaplon, Lukasz
    Kochanowski, Andrzej
    Konopka-Cupial, Gabriela
    Korcyl, Grzegorz
    Krzemien, Wojciech
    Lojek, Konrad
    Majewski, Jerzy
    Migdal, Wojciech
    Molenda, Marcin
    Niedzwiecki, Szymon
    Palka, Marek
    Rudy, Zbigniew
    Salabura, Piotr
    Silarski, Michal
    Slomski, Artur
    Smyrski, Jerzy
    Zdebik, Jaroslaw
    Zielinski, Marcin
    NUCLEAR MEDICINE REVIEW, 2012, 15 : C68 - C69
  • [30] J-PET analysis framework for the prototype TOF-PET detector
    Krzemien, Wojciech
    Silarski, Michal
    Stola, Karol
    Trybek, Damian
    Bednarski, Tomasz
    Bialas, Piotr
    Czerwinski, Eryk
    Kaplon, Lukasz
    Kochanowski, Andrzej
    Korcyl, Grzegorz
    Kowal, Jakub
    Kowalski, Pawel
    Kozik, Tomasz
    Molenda, Marcin
    Moskal, Pawel
    Niedzwiecki, Szymon
    Palka, Marek
    Pawlik, Monika
    Raczynski, Lech
    Rudy, Zbigniew
    Salabura, Piotr
    Sharma, Neha Gupta
    Slomski, Artur
    Smyrski, Jerzy
    Strzelecki, Adam
    Wislicki, Wojciech
    Zielinski, Marcin
    Zon, Natalia
    BIO-ALGORITHMS AND MED-SYSTEMS, 2014, 10 (01) : 33 - 36