Data driven time alignment for TOF-PET

被引:0
|
作者
Rezaei, Ahmadreza [1 ]
Schramm, Georg [1 ]
Van Laere, Koenraad [1 ]
Nuyts, Johan [1 ]
机构
[1] Katholieke Univ Leuven, Nucl Med, B-3000 Leuven, Belgium
关键词
CALIBRATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The accuracy of joint reconstruction methods using time of flight (TOF) positron emission tomography (PET) data, highly depends on an accurate model of the TOF measurements. In this contribution we consider the relative positioning of the TOF data-bins along each line of response (LOR) from TOF-PET emission data. Similar to an existing data-driven method, we assume that any shifts of TOF data-bins along lines of response can be modelled as differences between crystal timing offsets. Results are shown with and without accounting for the estimated TOF shifts for phantom and patient brain scans.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Dose Optimization in TOF-PET/MR Compared to TOF-PET/CT
    Queiroz, Marcelo A.
    Delso, Gaspar
    Wollenweber, Scott
    Deller, Timothy
    Zeimpekis, Konstantinos
    Huellner, Martin
    Barbosa, Felipe de Galiza
    von Schulthess, Gustav
    Veit-Haibach, Patrick
    PLOS ONE, 2015, 10 (07):
  • [2] Improvement of the Sign Determination Method for Data-Driven respiratory signal in TOF-PET
    Bertolli, Ottavia
    Arridge, Simon
    Stearns, Charles W.
    Wollenweber, Scott D.
    Hutton, Brian F.
    Thielemans, Kris
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [3] Time rectification system for in-beam TOF-PET
    Chen, Jin-Da
    Xu, Hu-Shan
    Chen, Ruo-Fu
    Hu, Zheng-Guo
    Tang, Bin
    Wu, Da-Peng
    Yue, Ke
    Yu, Yu-Hong
    Zhang, Xue-Heng
    Kong, Jie
    Ye, Rui-Ping
    Wang, Jian-Song
    Zhang, Xue-Ying
    Guo, Zhong-Yan
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2011, 45 (01): : 97 - 101
  • [4] Characterization of Scintillation Pulses in Time Determination in TOF-PET
    Guo, Ning
    Xie, Qingguo
    Zhu, Jun
    2009 16TH IEEE-NPSS REAL TIME CONFERENCE, 2009, : 304 - 307
  • [5] MAP reconstruction for Fourier rebinned TOF-PET data
    Bai, Bing
    Lin, Yanguang
    Zhu, Wentao
    Ren, Ran
    Li, Quanzheng
    Dahlbom, Magnus
    DiFilippo, Frank
    Leahy, Richard M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (04): : 925 - 949
  • [6] Investigation of the time performance of a LYSO array for TOF-PET
    Liu Jun-Hui
    Cheng Jin-Xing
    Xu Jiong-Hui
    Cheng Feng-Feng
    Li Dao-Wu
    Zhang Zhi-Ming
    Wang Bao-Yi
    Wei Long
    CHINESE PHYSICS C, 2015, 39 (12)
  • [7] Investigation of the time performance of a LYSO array for TOF-PET
    刘军辉
    程金星
    徐炯辉
    成枫锋
    李道武
    章志明
    王宝义
    魏龙
    Chinese Physics C, 2015, 39 (12) : 107 - 112
  • [8] Analytical model of coincidence resolving time in TOF-PET
    Wieczorek, H.
    Thon, A.
    Dey, T.
    Khanin, V.
    Rodnyi, P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (12): : 4699 - 4710
  • [9] Clinical Evaluation of PET Image Quality as a Function of Acquisition Time in a New TOF-PET/MRI Compared to TOF-PET/CT—Initial Results
    Konstantinos G. Zeimpekis
    Felipe Barbosa
    Martin Hüllner
    Edwin ter Voert
    Helen Davison
    Patrick Veit-Haibach
    Gaspar Delso
    Molecular Imaging and Biology, 2015, 17 : 735 - 744
  • [10] Clinical evaluation of PET image quality as a function of acquisition time in a new TOF-PET/MR compared to TOF-PET/CT - initial results
    Konstantinos Zeimpekis
    Martin Huellner
    Felipe De Galiza Barbosa
    Edwin Ter Voert
    Helen Davison
    Gaspar Delso
    Patrick Veit-Haibach
    EJNMMI Physics, 2 (Suppl 1)