Experimental study of concrete-filled CHS stub columns with inner FRP tubes

被引:42
|
作者
Long, Yue-Ling [1 ,3 ]
Li, Wen-Tao [1 ]
Dai, Jian-Guo [2 ]
Gardner, Leroy [3 ]
机构
[1] Guangdong Univ Technol, Dept Civil Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Hong Kong, Peoples R China
[3] Imperial Coll London, Dept Civil & Environm Engn, London SW7 2AZ, England
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Axial compression; Composite; Concrete-filled steel tube; Ductility; Experiments; Inner FRP tube; Load bearing capacity; STEEL TUBULAR COLUMNS; STRESS-STRAIN MODEL; CONFINED CONCRETE; BOX COLUMNS; BEHAVIOR; STRENGTH; TESTS; HOLLOW; HSC;
D O I
10.1016/j.tws.2017.10.046
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental study into the axial compressive behaviour of concrete-filled circular hollow section (CHS) steel columns with internal fibre reinforced polymer (FRP) tubes is presented in this paper. A total of 17 concrete filled steel tubular (CFST) columns were tested, 15 with an inner FRP tube and 2 with no inner tube. Complementary material tests and tests on 15 FRP-confined concrete (FCC) columns were also carried out. The varied test parameters included the concrete strength, the ratio of the diameter of the steel tube to that of the FRP tube, the diameter to wall thickness ratio of the inner FRP tube and the type (influencing principally the rupture strain) of the FRP. It was found that the presence of the inner FRP tube led to considerably improved axial compressive behaviour due to the greater levels of confinement afforded to the 'doubly-confined' inner concrete core; the load-bearing capacity was increased by between about 10% and 50% and the ductility was also enhanced. Greater benefits arose with (1) increasing diameter of the inner FRP tube due to the increased portion of the cross-section that is doubly-confined and (2) increasing wall thickness of the inner FRP tube due to the increased level of confinement afforded to the inner concrete core. The load-deflection responses of all tested specimens were reported, revealing that failure was generally gradual with no sharp loss in load-bearing capacity, implying that the embedment of the inner FRP tube within the concrete enables it to continue to provide a reasonable degree of confinement even after the initiation of fibre rupture; this is different to the sudden loss of confinement typically observed in FRP externally jacketed concrete columns.
引用
收藏
页码:606 / 621
页数:16
相关论文
共 50 条
  • [31] Experimental investigation on sea sand concrete-filled stainless steel tubular stub columns
    Liao, Fei-Yu
    Hou, Chao
    Zhang, Wei-Jie
    Ren, Jie
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 155 : 46 - 61
  • [32] Experimental and numerical investigations of square concrete-filled double steel tubular stub columns
    Ci, Junchang
    Ahmed, Mizan
    Jia, Hong
    Chen, Shicai
    Zhou, Daxing
    Hou, Liqun
    ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (11) : 2441 - 2456
  • [33] Geopolymer concrete-filled FRP tubes: Behavior of circular and square columns under axial compression
    Ozbakkaloglu, Togay
    Xie, Tianyu
    COMPOSITES PART B-ENGINEERING, 2016, 96 : 215 - 230
  • [34] Fiber element modeling for seismic performance of bridge columns made of concrete-filled FRP tubes
    Zhu, Zhenyu
    Ahmad, Iftekhar
    Mirmiran, Amir
    ENGINEERING STRUCTURES, 2006, 28 (14) : 2023 - 2035
  • [35] Compressive behavior of concrete-filled FRP tubes with FRP solid waste as recycled aggregates: Experimental study and analytical modelling
    Zhang, Bing
    Sun, Jiaming
    Zhang, Sumei
    Zhou, Chong
    Fan, Zhihong
    Yan, Yunhao
    Lin, Guan
    JOURNAL OF BUILDING ENGINEERING, 2024, 95
  • [36] Concrete-filled double skin (SHS outer and CHS inner) steel tubular beam-columns
    Han, LH
    Tao, Z
    Huang, H
    Zhao, XL
    THIN-WALLED STRUCTURES, 2004, 42 (09) : 1329 - 1355
  • [37] Effect of Recycled Concrete on the Flexural Behavior of Concrete-Filled FRP Tubes
    Lee, Heeyoung
    Jang, Hoon
    Chung, Wonseok
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2019, 13 (01)
  • [38] Effect of Recycled Concrete on the Flexural Behavior of Concrete-Filled FRP Tubes
    Heeyoung Lee
    Hoon Jang
    Wonseok Chung
    International Journal of Concrete Structures and Materials, 2019, 13
  • [39] Mechanical behavior of concrete-filled steel tubes stub columns with circular section under local compression
    School of Civil Engineering, Central South Univ, Changsha
    Hunan
    410075, China
    不详
    Hunan
    410075, China
    Hunan Daxue Xuebao, 11 (33-40):
  • [40] Influence of shrinkage on compressive behavior of concrete-filled FRP tubes: An experimental study on interface gap effect
    Vincent, Thomas
    Ozbakkaloglu, Togay
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 75 : 144 - 156