Experimental study of concrete-filled CHS stub columns with inner FRP tubes

被引:42
|
作者
Long, Yue-Ling [1 ,3 ]
Li, Wen-Tao [1 ]
Dai, Jian-Guo [2 ]
Gardner, Leroy [3 ]
机构
[1] Guangdong Univ Technol, Dept Civil Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Civil & Environm Engn, Hong Kong, Hong Kong, Peoples R China
[3] Imperial Coll London, Dept Civil & Environm Engn, London SW7 2AZ, England
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Axial compression; Composite; Concrete-filled steel tube; Ductility; Experiments; Inner FRP tube; Load bearing capacity; STEEL TUBULAR COLUMNS; STRESS-STRAIN MODEL; CONFINED CONCRETE; BOX COLUMNS; BEHAVIOR; STRENGTH; TESTS; HOLLOW; HSC;
D O I
10.1016/j.tws.2017.10.046
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An experimental study into the axial compressive behaviour of concrete-filled circular hollow section (CHS) steel columns with internal fibre reinforced polymer (FRP) tubes is presented in this paper. A total of 17 concrete filled steel tubular (CFST) columns were tested, 15 with an inner FRP tube and 2 with no inner tube. Complementary material tests and tests on 15 FRP-confined concrete (FCC) columns were also carried out. The varied test parameters included the concrete strength, the ratio of the diameter of the steel tube to that of the FRP tube, the diameter to wall thickness ratio of the inner FRP tube and the type (influencing principally the rupture strain) of the FRP. It was found that the presence of the inner FRP tube led to considerably improved axial compressive behaviour due to the greater levels of confinement afforded to the 'doubly-confined' inner concrete core; the load-bearing capacity was increased by between about 10% and 50% and the ductility was also enhanced. Greater benefits arose with (1) increasing diameter of the inner FRP tube due to the increased portion of the cross-section that is doubly-confined and (2) increasing wall thickness of the inner FRP tube due to the increased level of confinement afforded to the inner concrete core. The load-deflection responses of all tested specimens were reported, revealing that failure was generally gradual with no sharp loss in load-bearing capacity, implying that the embedment of the inner FRP tube within the concrete enables it to continue to provide a reasonable degree of confinement even after the initiation of fibre rupture; this is different to the sudden loss of confinement typically observed in FRP externally jacketed concrete columns.
引用
收藏
页码:606 / 621
页数:16
相关论文
共 50 条
  • [1] Numerical study of concrete-filled austenitic stainless steel CHS stub columns with high-strength steel inner tubes
    Wang, F.
    Young, B.
    Gardner, L.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 343 - 350
  • [2] Analytical study of concrete-filled steel tubular stub columns with double inner steel tubes
    Ayough, Pouria
    Wang, Yu-Hang
    Ibrahim, Zainah
    STEEL AND COMPOSITE STRUCTURES, 2023, 47 (05): : 645 - 661
  • [3] Behaviour of concrete-filled double skin (CHS inner and CHS outer) steel tubular stub columns and beam-columns
    Tao, Z
    Han, LH
    Zhao, XL
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2004, 60 (08) : 1129 - 1158
  • [4] Tests of concrete-filled double skin (SHS outer and CHS inner) composite stub columns
    Zhao, XL
    Grzebieta, RH
    Ukur, A
    Elchalakani, M
    ADVANCES IN STEEL STRUCTURES, VOLS I & II, PROCEEDINGS, 2002, : 567 - 574
  • [5] Tests of concrete-filled double skin CHS composite stub columns
    Zhao, XL
    Grzebieta, R
    Elchalakani, M
    STEEL AND COMPOSITE STRUCTURES, 2002, 2 (02): : 129 - 146
  • [6] Experimental Investigation of Concrete-filled Aluminum Stub Columns
    Zhou, Feng
    Young, Ben
    STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, 2009, : 245 - 252
  • [7] Experimental and numerical investigation of square concrete-filled double-skin steel stiffened tubular stub columns with CHS inner tubes under axial compression
    Huang, Wei-Feng
    Shao, Yong-Bo
    Hassanein, M. F.
    Hadzima-Nyarko, Marijana
    Radu, Dorin
    Cashell, K. A.
    THIN-WALLED STRUCTURES, 2024, 199
  • [8] Repair of concrete-filled FRP tube columns with damaged tubes
    Hutcheson, Zachary
    Fam, Amir
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 422
  • [9] Concrete-filled FRP tubes tested
    不详
    CIVIL ENGINEERING, 2000, 70 (03): : 28 - 28
  • [10] Tests of concrete-filled aluminum stub columns
    Zhou, Feng
    Young, Ben
    THIN-WALLED STRUCTURES, 2008, 46 (06) : 573 - 583