A COMPARISON OF OUT-OF-FIELD DOSE AND ITS CONSTITUENT COMPONENTS FOR INTENSITY-MODULATED RADIATION THERAPY VERSUS CONFORMAL RADIATION THERAPY: IMPLICATIONS FOR CARCINOGENESIS

被引:55
|
作者
Ruben, Jeremy D. [1 ,2 ]
Lancaster, Craig M. [1 ]
Jones, Phillip [1 ]
Smith, Ryan L. [1 ]
机构
[1] William Buckland Radiotherapy Ctr, Melbourne, Vic 3004, Australia
[2] Monash Univ, Melbourne, Vic 3004, Australia
关键词
IMRT; scatter; leakage; second cancer risk; 3D conformal radiation therapy; RADIOTHERAPY; IMRT; EQUIVALENT; NEUTRON; RISK; MV; MALIGNANCIES; IMPACT; PHOTON; HEAD;
D O I
10.1016/j.ijrobp.2010.08.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate differences in scatter and leakage between 6-MV intensity-modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3DCRT); to describe the relative contributions of internal patient scatter, collimator scatter, and head leakage; and to discuss implications for second cancer induction. Methods and Materials: Dose was measured at increasing distances from the field edge in a water bath with a sloping wall (I) under full scatter conditions, (2) with the field edge abutting but outside the bath to prevent internal (water) scatter, and (3) with the beam aperture plugged to reflect leakage only. Results: Internal patient scatter from IMRT is 11% lower than 3DCRT, but collimator scatter and head leakage are five and three times higher, respectively. Ultimately, total scattered dose is 80% higher with IMRT; however this difference is small in absolute terms, being 0.14% of prescribed dose. Secondary dose from 3DCRT is mostly due to internal patient scatter, which contributes 70% of the total and predominates until 25 cm from the field edge. For IMRT, however, machine scatter/leakage is the dominant source, contributing 65% of the secondary dose. Internal scatter predominates for just the first 10 cm from field edge, collimator scatter for the next 10 cm, and head leakage thereafter. Conclusions: Out-of-field dose is 80% higher with IMRT, but differences are tiny in absolute terms. Reductions in internal patient scatter with IMRT are outweighed by increased machine scatter and leakage, at least for small fields. Reductions from IMRT in dose to tissues within the portals and in internal scatter, which predominates close to the field edge, means that calculations based solely on dose to distant tissues may overestimate carcinogenic risks. (C) 2011 Elsevier Inc.
引用
收藏
页码:1458 / 1464
页数:7
相关论文
共 50 条
  • [41] A COMPARISON OF HELICAL INTENSITY-MODULATED RADIOTHERAPY, INTENSITY-MODULATED RADIOTHERAPY, AND 3D-CONFORMAL RADIATION THERAPY FOR PANCREATIC CANCER
    Poppe, Matthew M.
    Narra, Venkat
    Yue, Ning J.
    Zhou, Jinghao
    Nelson, Carl
    Jabbour, Salma K.
    MEDICAL DOSIMETRY, 2011, 36 (04) : 351 - 357
  • [42] Conformal Radiotherapy with Sequential Boost Versus Intensity-Modulated Radiation Therapy with a Simultaneously Integrated Boost
    Komisopoulos, G.
    Tolia, M.
    Siountas, A.
    Stathakis, S.
    Papanikolaou, N.
    Mavroidis, P.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [43] Toxicity of Stereotactic Body Radiation Therapy Versus Intensity-Modulated Radiation Therapy for Prostate Cancer: A Potential Comparison Bias
    Arcangeli, Stefano
    De Bari, Berardino
    Alongi, Filippo
    JOURNAL OF CLINICAL ONCOLOGY, 2014, 32 (30) : 3454 - 3454
  • [44] Hematologic Toxicity Comparison of Intensity-Modulated Proton Therapy and Intensity-Modulated Radiation Therapy in Anal Cancer Patients
    Nelson, B.
    Tadesse, D.
    Wang, K.
    Meier, T.
    Mascia, A. E.
    Kharofa, J. R., Jr.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E64 - E65
  • [45] On the role of intensity-modulated radiation therapy in radiation oncology
    Schulz, RJ
    Kagan, AR
    MEDICAL PHYSICS, 2002, 29 (07) : 1473 - 1482
  • [46] Development of radiation therapy techniques including intensity-modulated radiation therapy
    Ito, Yoshinori
    ANNALS OF ONCOLOGY, 2016, 27
  • [47] Treatment-related complications of radiation therapy after radical prostatectomy: comparative effectiveness of intensity-modulated versus conformal radiation therapy
    Crandley, Edwin F.
    Hegarty, Sarah E.
    Hyslop, Terry
    Wilson, David D.
    Dicker, Adam P.
    Showalter, Timothy N.
    CANCER MEDICINE, 2014, 3 (02): : 397 - 405
  • [48] Intensity-modulated carbon-ion radiation therapy versus intensity-modulated photon-based radiation therapy in locally recurrent nasopharyngeal carcinoma: a dosimetric comparison
    Wang, Lei
    Hu, Jiyi
    Liu, Xiaoli
    Wang, Weiwei
    Kong, Lin
    Lu, Jiade J.
    CANCER MANAGEMENT AND RESEARCH, 2019, 11 : 7767 - 7777
  • [49] Salivary Gland Volume Changes and Dry Mouth Symptom Following Definitive Radiation Therapy in Oropharyngeal Cancer Patients-A Comparison of Two Different Approaches: Intensity-Modulated Radiation Therapy Versus Intensity-Modulated Radiation Therapy/Intensity-Modulated Proton Therapy Combination
    Park, Seung Gyu
    Ahn, Yong Chan
    Oh, Dongryul
    Yang, Kyungmi
    Ju, Sang Gyu
    Kim, Jin Man
    Kwon, Dongyeol
    Choi, Euncheol
    Yoon, Han Gyul
    CANCERS, 2025, 17 (03)
  • [50] Comparison of intensity-modulated radiation therapy (IMRT), 3D conformal proton therapy and intensity-modulated proton therapy (IMPT) for the treatment of metastatic brain cancer
    Sullivan, Matthew
    Jin, Hosang
    Ahmad, Salahuddin
    MEDICAL DOSIMETRY, 2023, 48 (02) : 73 - 76