A COMPARISON OF OUT-OF-FIELD DOSE AND ITS CONSTITUENT COMPONENTS FOR INTENSITY-MODULATED RADIATION THERAPY VERSUS CONFORMAL RADIATION THERAPY: IMPLICATIONS FOR CARCINOGENESIS

被引:55
|
作者
Ruben, Jeremy D. [1 ,2 ]
Lancaster, Craig M. [1 ]
Jones, Phillip [1 ]
Smith, Ryan L. [1 ]
机构
[1] William Buckland Radiotherapy Ctr, Melbourne, Vic 3004, Australia
[2] Monash Univ, Melbourne, Vic 3004, Australia
关键词
IMRT; scatter; leakage; second cancer risk; 3D conformal radiation therapy; RADIOTHERAPY; IMRT; EQUIVALENT; NEUTRON; RISK; MV; MALIGNANCIES; IMPACT; PHOTON; HEAD;
D O I
10.1016/j.ijrobp.2010.08.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate differences in scatter and leakage between 6-MV intensity-modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3DCRT); to describe the relative contributions of internal patient scatter, collimator scatter, and head leakage; and to discuss implications for second cancer induction. Methods and Materials: Dose was measured at increasing distances from the field edge in a water bath with a sloping wall (I) under full scatter conditions, (2) with the field edge abutting but outside the bath to prevent internal (water) scatter, and (3) with the beam aperture plugged to reflect leakage only. Results: Internal patient scatter from IMRT is 11% lower than 3DCRT, but collimator scatter and head leakage are five and three times higher, respectively. Ultimately, total scattered dose is 80% higher with IMRT; however this difference is small in absolute terms, being 0.14% of prescribed dose. Secondary dose from 3DCRT is mostly due to internal patient scatter, which contributes 70% of the total and predominates until 25 cm from the field edge. For IMRT, however, machine scatter/leakage is the dominant source, contributing 65% of the secondary dose. Internal scatter predominates for just the first 10 cm from field edge, collimator scatter for the next 10 cm, and head leakage thereafter. Conclusions: Out-of-field dose is 80% higher with IMRT, but differences are tiny in absolute terms. Reductions in internal patient scatter with IMRT are outweighed by increased machine scatter and leakage, at least for small fields. Reductions from IMRT in dose to tissues within the portals and in internal scatter, which predominates close to the field edge, means that calculations based solely on dose to distant tissues may overestimate carcinogenic risks. (C) 2011 Elsevier Inc.
引用
收藏
页码:1458 / 1464
页数:7
相关论文
共 50 条
  • [31] Commentary - Intensity-modulated radiation therapy
    Goffman, TE
    Glatstein, E
    RADIATION RESEARCH, 2002, 158 (01) : 115 - 117
  • [32] Intensity-modulated proton therapy (IMPT) versus intensity-modulated radiation therapy (IMRT) for the treatment of head and neck cancer: A dosimetric comparison
    Nguyen, My-Lien
    Cantrell, J. Nathan
    Ahmad, Salahuddin
    Henson, Christina
    MEDICAL DOSIMETRY, 2021, 46 (03) : 259 - 263
  • [33] Intensity-Modulated Radiation Therapy - Foreword
    Johnstone, PAS
    CURRENT PROBLEMS IN CANCER, 2004, 28 (02) : 46 - 46
  • [34] A review of intensity-modulated radiation therapy
    Laurie E. Gaspar
    Meisong Ding
    Current Oncology Reports, 2008, 10 : 294 - 299
  • [35] The physics of intensity-modulated radiation therapy
    Boyer, AL
    PHYSICS TODAY, 2002, 55 (09) : 38 - 44
  • [36] A Review of Intensity-Modulated Radiation Therapy
    Gaspar, Laurie E.
    Ding, Meisong
    CURRENT ONCOLOGY REPORTS, 2008, 10 (04) : 294 - 299
  • [37] Evaluation of bladder dose in intensity-modulated radiation therapy of the prostate
    Higgins, P. D.
    Weaver, R.
    Dusenbery, K. E.
    MEDICAL DOSIMETRY, 2006, 31 (03) : 197 - 200
  • [38] Comparison of three-dimensional conformal radiation therapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy in the treatment of cervical esophageal carcinoma
    Yang, Hao
    Feng, Cong
    Cai, Bo-Ning
    Yang, Jun
    Liu, Hai-Xia
    Ma, Lin
    DISEASES OF THE ESOPHAGUS, 2017, 30 (02):
  • [39] Relative profile and dose verification of intensity-modulated radiation therapy
    Chang, JW
    Mageras, GS
    Chui, CS
    Ling, CC
    Lutz, W
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (01): : 231 - 240
  • [40] Intensity-Modulated Radiation Therapy, Proton Therapy, or Conformal Radiation Therapy and Morbidity and Disease Control in Localized Prostate Cancer
    Sheets, Nathan C.
    Goldin, Gregg H.
    Meyer, Anne-Marie
    Wu, Yang
    Chang, YunKyung
    Stuermer, Til
    Holmes, Jordan A.
    Reeve, Bryce B.
    Godley, Paul A.
    Carpenter, William R.
    Chen, Ronald C.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 307 (15): : 1611 - 1620