Redundant Control of Power Transformer Cooling System Using Actual Load Indicator

被引:0
|
作者
Prakoso, M. Helmi [1 ]
Gunawan, Heri [1 ]
机构
[1] PT PLN Persero KITLUR Kalimantan, West Kalimantan AP2B, Pontianak, Indonesia
来源
PROCEEDINGS OF 2018 THE 10TH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY AND ELECTRICAL ENGINEERING (ICITEE) | 2018年
关键词
power transformer; cooling system; load indicator; ageing;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The ageing of power transformer is subjected to the winding insulation and the oil inside the transformer. One of the problem that lead to the breakdown of insulation is caused by the change of thermal heating whether from inside or outside the transformer. The other case that is caused the breakdown of the insulation of power transformer is the transformer loading dispatch. The transformer cooling system has included the electrical fan to serve as a coolant utility for the radiator. It has been the effective method to keep the thermal condition of power transformer has a good condition toward the operation time. The existing cooling system use thermocouple as a sensor for the thermal indicator. This system is often being fragile and can cause the accelerating of transformer ageing. The system has been enhanced by creating the cooling system using load indicator as a redundant system for power transformer cooling system. This improvisation has been implemented to keep the good condition of thermal condition in power transformer.
引用
收藏
页码:568 / 572
页数:5
相关论文
共 50 条
  • [31] Heat Transfer and Fluid Flow Analysis of Power Transformer's Cooling System Using CFD Approach
    Nabati, Hamid
    Mahmoudi, Jafar
    Ehteram, Ali
    CHEMICAL PRODUCT AND PROCESS MODELING, 2009, 4 (01):
  • [32] Research on Maximum Power Point Tracking in Redundant Load Mode for Photovoltaic System
    王建军
    陈善本
    邵宇丰
    JournalofShanghaiJiaotongUniversity(Science), 2016, 21 (03) : 257 - 262
  • [33] LOAD FREQUENCY CONTROL USING BATTERY ENERGY STORAGE SYSTEM IN INTERCONNECTED POWER SYSTEM
    Kalyani, S.
    Nagalakshmi, S.
    Marisha, R.
    2012 THIRD INTERNATIONAL CONFERENCE ON COMPUTING COMMUNICATION & NETWORKING TECHNOLOGIES (ICCCNT), 2012,
  • [34] RESEARCH ON DIGITAL INSTRUMENTATION AND CONTROL SYSTEM IN NUCLEAR POWER PLANT USING MIXED REDUNDANT MODEL
    Ke, Zhiwu
    Li, Xianling
    Yu, Rui
    Xiang, Rui
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 5, 2014,
  • [35] Research on Dynamic Vibration of Transformer With Wireless Power Transfer System Load
    Zhu, Lihua
    Yang, Qingxin
    Yan, Rongge
    Zhang, Xian
    Yang, Yimei
    IEEE TRANSACTIONS ON MAGNETICS, 2015, 51 (11)
  • [36] Intelligent Control System of Transformer Cooling Based on DCS and Dual PLC
    Chen, Guojin
    Xu, Ming
    Liu, Tingting
    Ni, Jing
    Xie, Dong
    Zhang, Yanping
    2013 FIFTH INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION (ICMTMA 2013), 2013, : 648 - 651
  • [37] Load Control Using Sensitivity Identification by Means of Smart Transformer
    De Carne G.
    Buticchi G.
    Liserre M.
    Vournas C.
    2018, Institute of Electrical and Electronics Engineers Inc., United States (09) : 2606 - 2615
  • [38] Load Control using Sensitivity Identification by means of Smart Transformer
    De Came, Giovanni
    Buticchi, Giampaolo
    Liserre, Marco
    Vournas, Costas
    2017 IEEE MANCHESTER POWERTECH, 2017,
  • [39] Load Control Using Sensitivity Identification by Means of Smart Transformer
    De Carne, Giovanni
    Buticchi, Giampaolo
    Liserre, Marco
    Vournas, Constantine
    IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (04) : 2606 - 2615
  • [40] Adaptive Active Noise Control System of Power Transformer
    Liang, Jiabi
    Zhao, Tong
    Zou, Liang
    Zhang, Li
    Li, Zhongxu
    2015 FIFTH INTERNATIONAL CONFERENCE ON INSTRUMENTATION AND MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC), 2015, : 1394 - 1397