Scleral Lens Clearance Assessment with Biomicroscopy and Anterior Segment Optical Coherence Tomography

被引:9
|
作者
Yeung, Debby [1 ]
Sorbara, Luigina [1 ]
机构
[1] Univ Waterloo, Sch Optometry & Vis Sci, Waterloo, ON, Canada
关键词
CONTACT-LENSES; KERATOCONUS; MANAGEMENT; CORNEA;
D O I
10.1097/OPX.0000000000001164
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE It is important to be able to accurately estimate the central corneal clearance when fitting scleral contact lenses. Tools available have intrinsic biases due to the angle of viewing, and therefore an idea of the amount of error in estimation will benefit the fitter. PURPOSE To compare the accuracy of observers' ability to estimate scleral contact lens central corneal clearance (CCC) with biomicroscopy to measurements using slit-lamp imaging and anterior segment optical coherence tomography (AS-OCT). METHODS In a Web-based survey with images of four scleral lens fits obtained with a slit-lamp video imaging system, participants were asked to estimate the CCC. Responses were compared with known values of CCC of these images determined with an image-processing program (digital CCC) and using the AS-OCT (AS-OCT CCC). Bland-Altman plots and concordance correlation coefficients were used to assess the agreement of CCC measured by the various methods. RESULTS Sixty-six participants were categorized for analysis based on the amount of experience with scleral lens fitting into novice, intermediate, or advanced fitters. Comparing the estimated CCC to the digital CCC, all three groups overestimated by an average of +27.3 67.3 m. The estimated CCC was highly correlated to the digital CCC (0.79, 0.92, and 0.94 for each group, respectively). Compared with the CCC measurements using AS-OCT, the three groups of participants overestimated by +103.3 m and had high correlations (0.79, 0.93, and 0.94 for each group). DISCUSSION Results from this study validate the ability of contact lens practitioners to observe and estimate the CCC in scleral lens fittings through the use of biomicroscopic viewing. Increasing experience with scleral lens fitting does not improve the correlation with measured CCC from digital or the AS-OCT. However, the intermediate and advanced groups display significantly less inter-observer variability compared with the novice group.
引用
收藏
页码:13 / 20
页数:8
相关论文
共 50 条
  • [21] Assessment of conjunctival, episcleral and scleral thickness in healthy individuals using anterior segment optical coherence tomography
    Teeuw, G. J.
    Vergouwen, D. P. C.
    Ramdas, W. D.
    Sanchez-Brea, L.
    Andrade De Jesus, D.
    Rothova, A.
    Vingerling, J. R.
    Ten Berge, J. C.
    ACTA OPHTHALMOLOGICA, 2024, 102 (05) : 573 - 580
  • [22] Imaging implanted keratoprostheses with anterior-segment optical coherence tomography and ultrasound biomicroscopy
    Garcia, Julian P. S., Jr.
    de la Cruz, Jose
    Rosen, Richard B.
    Buxton, Douglas E.
    CORNEA, 2008, 27 (02) : 180 - 188
  • [23] Correlation of anterior segment optical coherence tomography and ultrasound biomicroscopy in congenital corneal opacity
    Yangzes, Sonam
    Kaushik, Sushmita
    Malhotra, Chintan
    Thakur, Anchal
    Gupta, Amit
    Jain, Arun Kumar
    Jinagal, Jitender
    Pandav, Surinder Singh
    JOURNAL OF AAPOS, 2024, 28 (02):
  • [24] Assessment of anterior scleral thickness in Turkish open angle glaucoma patients: an anterior segment optical coherence tomography study
    Torun, Isil Merve
    Saridogan, Melike
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [25] Evaluation of the Effect of Scleral Buckling on Anterior Segment and Refractive Changes Using Anterior Segment Optical Coherence Tomography
    Wang, Minli
    Zhu, Juming
    Keyal, Khusbu
    Liao, Xin
    Chen, Lei
    Li, Hui
    Wang, Fang
    SEMINARS IN OPHTHALMOLOGY, 2024, 39 (01) : 74 - 82
  • [26] Insights into scleral violaceous hue in anterior scleritis: anterior segment optical coherence tomography evaluation
    Sutra, Plern
    Pothikamjorn, Thananop
    Lopez, Sarah
    Takhar, Jaskirat
    Chongchareon, Mathinee
    Keenan, Jeremy
    Gonzales, John A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2025,
  • [27] Comparison of anterior segment optical coherence tomography (OCT) and ultrasound biomicroscopy (UBM) in diagnosis of anterior scleritis
    Purgert, Robert
    Bessette, Angela
    Pichi, Francesco
    Lowder, Careen
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [28] Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
    Yu, Zi-Yan
    Huang, Ting
    Lu, Lu
    Qu, Bo
    WORLD JOURNAL OF CLINICAL CASES, 2020, 8 (15) : 3249 - U143
  • [29] Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
    Zi-Yan Yu
    Ting Huang
    Lu Lu
    Bo Qu
    World Journal of Clinical Cases, 2020, (15) : 3249 - 3258
  • [30] Lens thickness assessment : anterior segment optical coherence tomography versus A-scan ultrasonography
    Nikoo Hamzeh
    Sasan Moghimi
    Golshan Latifi
    Massood Mohammadi
    Nassim Khatibi
    Shan C.Lin
    International Journal of Ophthalmology, 2015, (06) : 1151 - 1155