Determination of Entrance Surface dose for Three Common Planar Diagnostic X-Ray Examinations

被引:1
|
作者
Jeyasugiththan, Jeyasingam [1 ]
Ehalagasthanna, G. P. N. T. [1 ]
Hishaam, Urshella [1 ]
Satharasinghe, D. M. [1 ]
机构
[1] Univ Colombo, Fac Sci, Dept Nucl Sci, Colombo 03, Sri Lanka
关键词
RADIOGRAPHY; QUALITY;
D O I
10.1093/rpd/ncac177
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Patient dose during diagnostic radiography procedures primarily depends on the entrance surface dose (ESD) and the exposure area. The purpose of this study was to determine ESD for five common diagnostic X-ray examinations using dose area product and X-ray tube output. The ESDs were estimated in a sample of 340 patients using normalised X-ray output from Philips-PrimaryDiagnost digital X-ray machine equipped with digital flat panel scintillator detector. The resultant mean ESDs for chest postero-anterior/lateral, lumbar spine antero-posterior (AP)/lateral and abdomen AP were 0.49, 2.00, 5.74, 12.79 and 4.62 mGy, respectively. The mean and third quartile ESD values of this study were significantly higher than the values found in the literature. This can be attributed to the lower tube potential (kV(p)) values and the higher tube current-time products (mAs). The methodology used here is a better option for low-resources countries for routine dose monitoring.
引用
收藏
页码:1361 / 1367
页数:7
相关论文
共 50 条
  • [1] Evaluation of the Entrance Surface Doses (ESD) for common diagnostic X-ray examinations
    Alomairy, Nada
    Hadi, Dareen
    Al-Zaid, Amna
    Fasikh, Rawan
    Arif, Raneem
    Al-Hazmi, Rawan
    Kharizy, Ali
    Alyami, Ali
    Hummdy, Ahmed
    Shubayr, Nasser
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (04)
  • [2] Entrance surface doses to patients undergoing selected diagnostic X-ray examinations in Sudan
    Suliman, I. I.
    Abbas, N.
    Habbani, F. I.
    RADIATION PROTECTION DOSIMETRY, 2007, 123 (02) : 209 - 214
  • [3] PATIENT DOSES IN COMMON DIAGNOSTIC X-RAY EXAMINATIONS
    Metaxas, Vasileios, I
    Messaris, Gerasimos A.
    Lekatou, Aristea N.
    Petsas, Theodore G.
    Panayiotakis, George S.
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (01) : 12 - 27
  • [4] Regional survey of entrance surface dose to patients from X-ray examinations in Saudi Arabia
    Saeed, M. K.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (02) : 299 - 303
  • [5] Regional survey of entrance surface dose to patients from X-ray examinations in Saudi Arabia
    M. K. Saeed
    Australasian Physical & Engineering Sciences in Medicine, 2015, 38 : 299 - 303
  • [6] Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals
    Johnston, DA
    Brennan, PC
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (868): : 396 - 402
  • [7] Radiation dose considerations in common paediatric X-ray examinations
    Gogos, KA
    Yakoumakis, EN
    Tsalafoutas, IA
    Makri, TK
    PEDIATRIC RADIOLOGY, 2003, 33 (04) : 236 - 240
  • [8] Radiation dose considerations in common paediatric X-ray examinations
    Konstantinos A. Gogos
    Emmanuel N. Yakoumakis
    Ioannis A. Tsalafoutas
    Triantafillia K. Makri
    Pediatric Radiology, 2003, 33 : 236 - 240
  • [9] ESTIMATION OF SKIN ENTRANCE DOSES (SEDs) FOR COMMON MEDICAL X-RAY DIAGNOSTIC EXAMINATIONS IN INDIA AND PROPOSED DIAGNOSTIC REFERENCE LEVELS (DRLs)
    Sonawane, A. U.
    Shirva, V. K.
    Pradhan, A. S.
    RADIATION PROTECTION DOSIMETRY, 2010, 138 (02) : 129 - 136
  • [10] Measurement of entrance surface dose to patients in four common diagnostic examinations by thermoluminescence dosimetry in Nigeria
    Ajayi, IR
    Akinwumiju, A
    RADIATION PROTECTION DOSIMETRY, 2000, 87 (03) : 217 - 220