Radiation dose considerations in common paediatric X-ray examinations

被引:65
|
作者
Gogos, KA
Yakoumakis, EN
Tsalafoutas, IA
Makri, TK
机构
[1] Univ Athens, Dept Phys Med, Sch Med, Athens 11527, Greece
[2] Konstantopoulio Agia Olga Hosp, Med Phys Unit, Athens, Greece
[3] Agia Sofia Hosp, Med Phys Unit, Athens, Greece
关键词
radiation dosimetry paediatric; radiography diagnostic; reference levels;
D O I
10.1007/s00247-002-0861-x
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: For paediatric radiology, diagnostic reference levels (DRLs) have been proposed by the National Radiological Protection Board and the European Commission, representing a baseline above which re-evaluation of the equipment and the techniques used is necessary. Objective: To measure the entrance surface dose (ESD) in various paediatric radiological examinations carried out at a large paediatric hospital in Greece and compare them with the existing DRLs. Materials and methods: Measurements of ESD using thermoluminescent dosemeters were carried out in a sample of 168 paediatric patients who underwent various common radiological examinations (chest, skull, pelvis, lumbar spine, full spine). The patients were categorised according to age, and the mean ESD was calculated for each examination and age category. Additionally, the effective doses were estimated from measured ESD using appropriate conversion coefficients found in the literature. Results: The mean ESD values were found to be well below the proposed DRLs for all the examinations studied except for the chest, owing to the low tube potential used and tube filtration. Conclusions: Even in examinations that did not exceed the DRL, patient protection can be optimised further by appropriate collimation of field size to that necessary for diagnosis.
引用
收藏
页码:236 / 240
页数:5
相关论文
共 50 条
  • [1] Radiation dose considerations in common paediatric X-ray examinations
    Konstantinos A. Gogos
    Emmanuel N. Yakoumakis
    Ioannis A. Tsalafoutas
    Triantafillia K. Makri
    [J]. Pediatric Radiology, 2003, 33 : 236 - 240
  • [2] Radiation doses from some common paediatric X-ray examinations in Sudan
    Suliman, I. I.
    Elshiekh, E. H. A.
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 132 (01) : 64 - 72
  • [3] Radiation doses in common X-ray examinations carried out in two dedicated paediatric hospitals
    Yakoumakis, Emmanuel N.
    Tsalafoutas, Ioannis A.
    Aliberti, Maria
    Pantos, George I.
    Yakoumakis, Nikolaos E.
    Karaiskos, Pantelis
    Georgiou, Evaggelos K.
    [J]. RADIATION PROTECTION DOSIMETRY, 2007, 124 (04) : 348 - 352
  • [4] Dose evaluation in paediatric patients undergoing chest X-ray examinations
    Piantini, F.
    Schelin, H. R.
    Denyak, V.
    Bunick, A. P.
    Legnani, A.
    Ledesma, J. A.
    Fihpov, D.
    Paschuk, S. A.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 283 - 289
  • [5] Patient dose measurement in common medical X-ray examinations in Iran
    Rasuli, Behrouz
    Mahmoud-Pashazadeh, Ali
    Ghorbani, Mohammad
    Juybari, Raheleh Tabari
    Naserpour, Mozafar
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 374 - 386
  • [6] EMERGENCY X-RAY EXAMINATIONS IN PAEDIATRIC PRACTICE
    WALKER, N
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1962, 35 (416): : 577 - 577
  • [7] EMERGENCY X-RAY EXAMINATIONS IN PAEDIATRIC PRACTICE
    WALKER, NM
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1963, 36 (421): : 11 - 18
  • [8] RADIATION EXPOSURE DURING X-RAY EXAMINATIONS IN A LARGE PAEDIATRIC HOSPITAL IN SERBIA
    Ciraj-Bjelac, Olivera
    Gavrilovic, Marijana
    Arandjic, Danijela
    Vujovic, Milan
    Bozovic, Predrag
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 220 - 225
  • [9] RADIATION-DOSE TO CHILDREN FROM X-RAY AND RADIOISOTOPE EXAMINATIONS
    BUSHONG, SC
    GLAZE, D
    GLAZE, S
    SINGLETON, E
    [J]. HEALTH PHYSICS, 1978, 35 (05): : 720 - 721
  • [10] Paediatric x-ray radiation dose reduction and image quality analysis
    Martin, L.
    Ruddlesden, R.
    Makepeace, C.
    Robinson, L.
    Mistry, T.
    Starritt, H.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2013, 33 (03) : 621 - 633