Correlation of pattern of visual field loss by perimetry and anterior chamber angle parameters by anterior segment optical coherence tomography in primary angle-closure glaucoma

被引:2
|
作者
Palanisamy, Sreeramyaa [1 ]
Raja, Vidya [1 ]
Senthilkumar, Vijayalakshmi A. [1 ]
Mani, Iswarya [2 ]
Krishnadas, R. [1 ]
机构
[1] Aravind Eye Hosp & Postgrad Inst Ophthalmol, Dept Glaucoma, Madurai, Tamil Nadu, India
[2] Aravind Eye Hosp & Postgrad Inst Ophthalmol, Dept Biostat, Madurai, Tamil Nadu, India
关键词
Anterior chamber angle parameters; AS-OCT; mean deviation; primary angle-closure glaucoma; visual field defects; CLASSIFICATION; SUBTYPES; PEOPLE; EYES;
D O I
10.4103/ijo.IJO_232_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To correlate and analyze the pattern of the visual field (VF) defects by perimetry and anterior chamber angle parameters by AS-OCT in primary angle-closure glaucoma (PACG) across varied severity levels on presentation to a tertiary eye care center. Methods: This was a cross-sectional study, which included 323 eyes of clinically diagnosed cases of PACG. Glaucoma severity was categorized according to mean deviation (MD) as mild (-6.00 dB or more), moderate (-6.01 to -12.00 dB), and severe (-12.01 to -30.00 dB). AS-OCT measured the nasal (N) and temporal (T) angle opening distance at 500 mu m (AOD 500) and 750 mu m (AOD 750), anterior chamber angle (ACM, lens vault (LV), and anterior chamber width (ACW) The VF severity was then correlated with the AS-OCT parameters using statistical analysis. Results: The mean age +/- standard deviation (SD) of the patients included in the study was 56.03 +/- 8.6 years, with a 1:1.2 gender ratio. The number of eyes with mild, moderate, and severe VFs were 140 (43.3%), 88 (27.24%), and 95 (29.41%), respectively. There was no statistically significant correlation in the mean anterior chamber angle parameters (AOD 500, AOD 750, ACA 500, ACA 750, LV, ACW, and axial length (AL)) among the groups. However, the correlation between AOD 500 and LV thickness was found to be significant (P = 0.0000) with a negative Spearman's rank correlation coefficient (r = -0.3329). Conclusion: The ACA parameters obtained by AS-OCT along the horizontal axis after elimination of pupillary block by laser peripheral iridotomy do not correlate and cannot be used to assess the disease severity of PACG.
引用
收藏
页码:2895 / 2901
页数:7
相关论文
共 50 条
  • [1] Subgrouping of Primary Angle-Closure Suspects Based on Anterior Segment Optical Coherence Tomography Parameters
    Nongpiur, Monisha E.
    Gong, Tianxia
    Lee, Hwee Kuan
    Perera, Shamira A.
    Cheng, Li
    Foo, Li-Lian
    He, Mingguang
    Friedman, David S.
    Aung, Tin
    OPHTHALMOLOGY, 2013, 120 (12) : 2525 - 2531
  • [2] Anterior Segment Optical Coherence Tomography Parameters in Subtypes of Primary Angle Closure
    Guzman, Celeste P.
    Gong, Tianxia
    Nongpiur, Monisha E.
    Perera, Shamira A.
    How, Alicia C.
    Lee, Hwee Kuan
    Cheng, Li
    He, Mingguang
    Baskaran, Mani
    Aung, Tin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (08) : 5281 - 5286
  • [3] Quantitative evaluation of anterior chamber parameters using anterior segment optical coherence tomography in primary angle closure mechanisms
    Shabana, Noor
    Aquino, Maria C. D.
    See, Jovina
    Ce, Zheng
    Tan, Anna M.
    Nolan, Winifred P.
    Hitchings, Roger
    Young, Stephanie M.
    Loon, Seng Chee
    Sng, Chelvin C.
    Wong, Wanling
    Chew, Paul T. K.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (08): : 792 - 801
  • [4] Anterior segment optical coherence tomography in subtypes of angle closure glaucoma
    Nouri-Mahdavi, Kouros
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2016, 28 (04): : 159 - 160
  • [5] Quantification of Anterior Chamber Particles Using Anterior Segment Optical Coherence Tomography in Angle-Closure Glaucoma Patients after Laser Iridotomy
    Yoshihara, Naoya
    Terasaki, Hiroto
    Shiihara, Hideki
    Funatsu, Ryoh
    Yamashita, Takehiro
    Sakamoto, Taiji
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (15)
  • [6] Swept-source optical coherence tomography and ultrasound biomicroscopy study of anterior segment parameters in primary angle-closure glaucoma
    Qianwen Bu
    Die Hu
    Hai Zhu
    Jianhong Jiang
    Ying Su
    Jingyi Wu
    Zongyi Li
    Xiaojing Pan
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 1651 - 1658
  • [7] Swept-source optical coherence tomography and ultrasound biomicroscopy study of anterior segment parameters in primary angle-closure glaucoma
    Bu, Qianwen
    Hu, Die
    Zhu, Hai
    Jiang, Jianhong
    Su, Ying
    Wu, Jingyi
    Li, Zongyi
    Pan, Xiaojing
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (6) : 1651 - 1658
  • [9] Anterior Chamber Angle Assessment by Anterior-segment Optical Coherence Tomography After Phacoemulsification With or Without Goniosynechialysis in Patients With Primary Angle Closure Glaucoma
    Shao, Tingting
    Hong, Jiaxu
    Xu, Jianjiang
    Le, Qihua
    Wang, Jiajian
    Qian, Shaohong
    JOURNAL OF GLAUCOMA, 2015, 24 (09) : 647 - 655
  • [10] Role of anterior segment optical coherence tomography in angle-closure disease: a review
    Porporato, Natalia
    Baskaran, Mani
    Aung, Tin
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 (02): : 147 - 157