Correlation of pattern of visual field loss by perimetry and anterior chamber angle parameters by anterior segment optical coherence tomography in primary angle-closure glaucoma

被引:0
|
作者
Palanisamy, Sreeramyaa [1 ]
Raja, Vidya [1 ]
Senthilkumar, Vijayalakshmi A. [1 ]
Mani, Iswarya [2 ]
Krishnadas, R. [1 ]
机构
[1] Aravind Eye Hosp & Postgrad Inst Ophthalmol, Dept Glaucoma, Madurai, Tamil Nadu, India
[2] Aravind Eye Hosp & Postgrad Inst Ophthalmol, Dept Biostat, Madurai, Tamil Nadu, India
关键词
Anterior chamber angle parameters; AS-OCT; mean deviation; primary angle-closure glaucoma; visual field defects; CLASSIFICATION; SUBTYPES; PEOPLE; EYES;
D O I
10.4103/ijo.IJO_232_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To correlate and analyze the pattern of the visual field (VF) defects by perimetry and anterior chamber angle parameters by AS-OCT in primary angle-closure glaucoma (PACG) across varied severity levels on presentation to a tertiary eye care center. Methods: This was a cross-sectional study, which included 323 eyes of clinically diagnosed cases of PACG. Glaucoma severity was categorized according to mean deviation (MD) as mild (-6.00 dB or more), moderate (-6.01 to -12.00 dB), and severe (-12.01 to -30.00 dB). AS-OCT measured the nasal (N) and temporal (T) angle opening distance at 500 mu m (AOD 500) and 750 mu m (AOD 750), anterior chamber angle (ACM, lens vault (LV), and anterior chamber width (ACW) The VF severity was then correlated with the AS-OCT parameters using statistical analysis. Results: The mean age +/- standard deviation (SD) of the patients included in the study was 56.03 +/- 8.6 years, with a 1:1.2 gender ratio. The number of eyes with mild, moderate, and severe VFs were 140 (43.3%), 88 (27.24%), and 95 (29.41%), respectively. There was no statistically significant correlation in the mean anterior chamber angle parameters (AOD 500, AOD 750, ACA 500, ACA 750, LV, ACW, and axial length (AL)) among the groups. However, the correlation between AOD 500 and LV thickness was found to be significant (P = 0.0000) with a negative Spearman's rank correlation coefficient (r = -0.3329). Conclusion: The ACA parameters obtained by AS-OCT along the horizontal axis after elimination of pupillary block by laser peripheral iridotomy do not correlate and cannot be used to assess the disease severity of PACG.
引用
收藏
页码:2895 / 2901
页数:7
相关论文
共 50 条
  • [31] The anterior and posterior biometric characteristics in primary angle-closure disease: Data based on anterior segment optical coherence tomography and swept-source optical coherence tomography
    Huang, Wenbin
    Li, Xingyi
    Gao, Xinbo
    Zhang, Xiulan
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (04) : 865 - 870
  • [32] Anatomical Changes of the Anterior Chamber Angle With Anterior-Segment Optical Coherence Tomography
    Liu, Lance
    ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (12) : 1682 - 1686
  • [33] Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography
    Radhakrishnan, Sunita
    See, Jovina
    Smith, Scott D.
    Nolan, Winifred P.
    Ce, Zheng
    Friedman, David S.
    Huang, David
    Li, Yan
    Aung, Tin
    Chew, Paul T. K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (08) : 3683 - 3688
  • [34] Effect of Hemodialysis on Anterior Chamber Angle Measured by Anterior Segment Optical Coherence Tomography
    Shin, Yong Un
    Kim, Ji Hong
    Cho, Heeyoon
    Kim, Dae Sung
    Yi, Joo-Hark
    Han, Sang-Woong
    Seong, Mincheol
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [35] Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography
    Li, Haitao
    Leung, Christopher Kai Shun
    Cheung, Carol Yim Lui
    Wong, Lee
    Pang, Chi Pui
    Weinreb, Robert Neal
    Lam, Dennis Shun Chiu
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (11) : 1490 - 1492
  • [36] Comparison of Anterior Segment-Optical Coherence Tomography Parameters in Phacomorphic Angle Closure and Acute Angle Closure Eyes
    Moghimi, Sasan
    Ramezani, Farshid
    He, Mingguang
    Coleman, Anne L.
    Lin, Shan C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (13) : 7611 - 7617
  • [37] Deconstructing the mechanisms of angle closure with anterior segment optical coherence tomography
    Liu, Lance
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (07): : 614 - 622
  • [38] Anterior Segment Parameters in Subjects with Asymmetric Primary Angle Closure Glaucoma
    Nongpiur, Monisha Esther
    Fan, Kenric R.
    Chiew, Jestin W.
    Cheong, Yap Sae
    Perera, Shamira
    Aung, Tin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [39] Reproducibility of Anterior Chamber Angle Measurements With Anterior Segment Coherence Tomography
    De Brabander, J.
    Tan, A. N.
    Berendschot, T. T. J. M.
    Sauren, L. D. C.
    Nekeman, D.
    Passos, V. Lima
    Webers, C. A. B.
    Beckers, H. J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [40] Goniometry with optical coherence tomography in angle-closure glaucoma
    Karandish, A
    Wirbelauer, C
    Häberle, H
    Pham, DT
    OPHTHALMOLOGE, 2006, 103 (01): : 35 - 39