Modelisation of strains measured by X-ray diffraction in composites with spherical particles

被引:0
|
作者
Durand, L [1 ]
Lavelle, B [1 ]
Drira-Halouani, R [1 ]
Altibelli, A [1 ]
机构
[1] CNRS, CEMES, FR-31055 Toulouse, France
来源
ECRS 5: PROCEEDINGS OF THE FIFTH EUROPEAN CONFERENCE ON RESIDUAL STRESSES | 2000年 / 347-3卷
关键词
interface reactivity; metallic matrix composites; modelisation; thermal strain; X-ray diffraction;
D O I
10.4028/www.scientific.net/MSF.347-349.536
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In a particle composite, elaboration residual stresses have two main origins : differences between thermal expansion coefficients of particles and matrix on the one hand, and volume changes induced by reactions at particles / matrix interface on the other hand. We have compared calculated thermal stresses, and experimental measures on two composites, one presenting an interface reactivity and the other none. The two composites with a nickel matrix and spherical particles either of silica or of alumina have been sintered at 1400 degreesC and analyzed between room temperature and 240 degreesC by Xray diffraction (Cu Ka radiation). In the semi-infinite composite model, spherical particles have been distributed at the points of a simple cubic lattice. Modelised thickness is larger in comparison of the thickness analyzed by X-ray diffraction. Calculations are based on elastic theory and the difference of coefficients of thermal expansion between the matrix and the particles. Materials are supposed isotropic. At a given temperature, the strain to be observed by X-ray diffraction in a given directions calculated from the distribution of strains in matrix; absorption phenomena are taken into account. Effects of the free surface and of interfacial reactivity are thus shown off.
引用
收藏
页码:536 / 541
页数:6
相关论文
共 50 条
  • [21] Thickness of polycrystalline copper coating measured by X-ray diffraction
    Skrzypek, S. J.
    Goly, M.
    Kowalska, J.
    Chrusciel, K.
    APPLIED CRYSTALLOGRAPHY XXI, 2010, 163 : 9 - 12
  • [23] Orientation of aqueous stretched cottons as measured by X-ray diffraction
    Devi, AS
    Subramaniam, V
    JOURNAL OF APPLIED POLYMER SCIENCE, 1996, 62 (08) : 1259 - 1262
  • [24] X-ray absorption and X-ray diffraction micro tomography of biodegradable polymer based composites
    Jaroszewicz, J.
    Idaszek, J.
    Vanmeert, F.
    Janssens, K.
    Bonnin, A.
    Swieszkowski, W.
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2012, 6 : 318 - 319
  • [25] Exploration of crystal strains using coherent x-ray diffraction
    Cha, Wonsuk
    Song, Sanghoon
    Jeong, Nak Cheon
    Harder, Ross
    Yoon, Kyung Byung
    Robinson, Ian K.
    Kim, Hyunjung
    NEW JOURNAL OF PHYSICS, 2010, 12
  • [26] Grain-resolved elastic strains in deformed copper measured by three-dimensional X-ray diffraction
    Oddershede, Jette
    Schmidt, Soren
    Poulsen, Henning Friis
    Margulies, Lawrence
    Wright, Jonathan
    Moscicki, Marcin
    Reimers, Walter
    Winther, Grethe
    MATERIALS CHARACTERIZATION, 2011, 62 (07) : 651 - 660
  • [27] Aspect ratio dependent strains in InAs/InP quantum dots measured by synchrotron radiation x-ray diffraction
    Kim, K
    Yoon, S
    Yoon, E
    Koo, YM
    Lee, JL
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2003, 21 (01): : 183 - 185
  • [28] Synthesis of Ti matrix composites reinforced with TiC particles: in situ synchrotron X-ray diffraction and modeling
    Andrieux, Jerome
    Gardiola, Bruno
    Dezellus, Olivier
    JOURNAL OF MATERIALS SCIENCE, 2018, 53 (13) : 9533 - 9544
  • [29] Synthesis of Ti matrix composites reinforced with TiC particles: in situ synchrotron X-ray diffraction and modeling
    Jérôme Andrieux
    Bruno Gardiola
    Olivier Dezellus
    Journal of Materials Science, 2018, 53 : 9533 - 9544
  • [30] Microstructure of energetic particles investigated by X-ray powder diffraction
    Herrmann, M
    PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 2006, 22 (06) : 401 - 406