Comparative calibration of IP scanning equipment

被引:7
|
作者
Ingenito, F. [1 ]
Andreoli, P. [1 ]
Batani, D. [2 ]
Boutoux, G. [2 ]
Cipriani, M. [1 ]
Consoli, F. [1 ]
Cristofari, G. [1 ]
Curcio, A. [3 ]
De Angelis, R. [1 ]
Di Giorgio, G. [1 ]
Ducret, J. [2 ]
Forestier-Colleoni, P. [2 ]
Hulin, S. [2 ]
Jakubowska, K. [2 ,4 ]
Rabhi, N. [2 ]
机构
[1] ENEA EuroFus, Rome, Italy
[2] Univ Bordeaux, CNRS, CEA, CELIA Ctr Lasers Intenses & Applicat,UMR 510, F-33405 Talence, France
[3] Univ Roma La Sapienza, Piazzale Aldo Moro 5, I-00185 Rome, Italy
[4] Insitute Plasma Phys & Laser Microfus, Warsaw, Poland
来源
关键词
Data processing methods; Detector alignment and calibration methods (lasers; sources; particle-beams); Particle detectors; X-ray detectors; LUMINESCENCE;
D O I
10.1088/1748-0221/11/05/C05012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Imaging Plates (IP) are diagnostic devices which contain a photostimulable phosphor layer that stores the incident radiation dose as a latent image. The image is read with a scanner which stimulates the decay of electrons, previously excited by the incident radiation, by exposition to a laser beam. This results in emitted light, which is detected by photomultiplier tubes; so the latent image is reconstructed. IPs have the interesting feature that can be reused many times, after erasing stored information. Algorithms to convert signals stored in the detector to Photostimulated luminescence (PSL) counts depend on the scanner and are not available on every model. A comparative cross-calibration of the IP scanner Durr CR35 BIO, used in ABC laboratory, was performed, using the Fujifilm FLA 7000 scanner as a reference, to find the equivalence between grey-scale values given by the Durr scanner to PSL counts. Using an IP and a Fe-55 beta-source, we produced pairs of samples with the same exposition times, which were analysed by both scanners, placing particular attention to fading times of the image stored on IPs. Data analysis led us to the determine a conversion formula which can be used to compare data of experiments obtained in different laboratories and to use IP calibrations available, till now, only for Fujifilm scanners.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] OPTICAL-SCANNING EQUIPMENT
    DEJONG, JH
    DATA PROCESSING, 1961, 3 (01): : 11 - 12
  • [22] RECENT ADVANCES IN SCANNING EQUIPMENT
    HARRIS, CC
    FRANCIS, JE
    BELL, PR
    HAMBLEN, DP
    EASON, HO
    JOURNAL OF NUCLEAR MEDICINE, 1960, 1 (02) : 115 - 115
  • [23] RECENT ADVANCES IN SCANNING EQUIPMENT
    HARRIS, CC
    FRANCIS, JE
    BELL, PR
    HAMBLEN, DP
    EASON, HO
    JOURNAL OF NUCLEAR MEDICINE, 1960, 1 (01) : 62 - 63
  • [24] THE CALORIC CALIBRATION OF SCANNING CALORIMETERS
    SARGE, SM
    GMELIN, E
    HOHNE, GWH
    CAMMENGA, HK
    HEMMINGER, W
    EYSEL, W
    THERMOCHIMICA ACTA, 1994, 247 (02) : 129 - 168
  • [25] Calibration of Scanning Electron Microscopes
    Bull Russ Acad Sci Phys, 2 (282):
  • [26] Calibration of the scanning electron microscopes
    Novikov, YA
    Rakov, AV
    Stekolin, IY
    IZVESTIYA AKADEMII NAUK SERIYA FIZICHESKAYA, 1996, 60 (02): : 148 - 154
  • [27] THE TEMPERATURE CALIBRATION OF SCANNING CALORIMETERS
    HOHNE, GWH
    CAMMENGA, HK
    EYSEL, W
    GMELIN, E
    HEMMINGER, W
    THERMOCHIMICA ACTA, 1990, 160 (01) : 1 - 12
  • [28] CALIBRATION OF DIFFERENTIAL SCANNING CALORIMETERS
    GMELIN, E
    SARGE, SM
    PURE AND APPLIED CHEMISTRY, 1995, 67 (11) : 1789 - 1800
  • [29] Concern over the calibration of test equipment
    British Plastics and Rubber, 1995,
  • [30] MEASURING AND TEST EQUIPMENT CALIBRATION SYSTEMS
    TURNBULL, DM
    QUALITY PROGRESS, 1983, 16 (05) : 28 - 33