Comparative calibration of IP scanning equipment

被引:7
|
作者
Ingenito, F. [1 ]
Andreoli, P. [1 ]
Batani, D. [2 ]
Boutoux, G. [2 ]
Cipriani, M. [1 ]
Consoli, F. [1 ]
Cristofari, G. [1 ]
Curcio, A. [3 ]
De Angelis, R. [1 ]
Di Giorgio, G. [1 ]
Ducret, J. [2 ]
Forestier-Colleoni, P. [2 ]
Hulin, S. [2 ]
Jakubowska, K. [2 ,4 ]
Rabhi, N. [2 ]
机构
[1] ENEA EuroFus, Rome, Italy
[2] Univ Bordeaux, CNRS, CEA, CELIA Ctr Lasers Intenses & Applicat,UMR 510, F-33405 Talence, France
[3] Univ Roma La Sapienza, Piazzale Aldo Moro 5, I-00185 Rome, Italy
[4] Insitute Plasma Phys & Laser Microfus, Warsaw, Poland
来源
关键词
Data processing methods; Detector alignment and calibration methods (lasers; sources; particle-beams); Particle detectors; X-ray detectors; LUMINESCENCE;
D O I
10.1088/1748-0221/11/05/C05012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Imaging Plates (IP) are diagnostic devices which contain a photostimulable phosphor layer that stores the incident radiation dose as a latent image. The image is read with a scanner which stimulates the decay of electrons, previously excited by the incident radiation, by exposition to a laser beam. This results in emitted light, which is detected by photomultiplier tubes; so the latent image is reconstructed. IPs have the interesting feature that can be reused many times, after erasing stored information. Algorithms to convert signals stored in the detector to Photostimulated luminescence (PSL) counts depend on the scanner and are not available on every model. A comparative cross-calibration of the IP scanner Durr CR35 BIO, used in ABC laboratory, was performed, using the Fujifilm FLA 7000 scanner as a reference, to find the equivalence between grey-scale values given by the Durr scanner to PSL counts. Using an IP and a Fe-55 beta-source, we produced pairs of samples with the same exposition times, which were analysed by both scanners, placing particular attention to fading times of the image stored on IPs. Data analysis led us to the determine a conversion formula which can be used to compare data of experiments obtained in different laboratories and to use IP calibrations available, till now, only for Fujifilm scanners.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] CALIBRATION AND STORAGE OF INSPECTION EQUIPMENT
    PITT, JA
    MACHINERY AND PRODUCTION ENGINEERING, 1977, 130 (3347): : 122 - 124
  • [12] SOLUTIONS FOR CALIBRATION OF GOUY EQUIPMENT
    FIGGIS, BN
    JOURNAL OF THE CHEMICAL SOCIETY, 1964, (SEP): : 3423 - &
  • [13] TEMPERATURE CALIBRATION OF THERMOGRAVIMETRIC EQUIPMENT
    CASH, AAJ
    LAYE, PG
    PANTING, AL
    THERMOCHIMICA ACTA, 1987, 113 : 205 - 208
  • [14] Laser alignment calibration equipment
    不详
    OPTICS AND LASER TECHNOLOGY, 1996, 28 (01): : R6 - R6
  • [15] The IXPE instrument calibration equipment
    Muleri, Fabio
    Piazzolla, Raffaele
    Di Marco, Alessandro
    Fabiani, Sergio
    La Monaca, Fabio
    Lefevre, Carlo
    Morbidini, Alfredo
    Rankin, John
    Soffitta, Paolo
    Tobia, Antonino
    Xie, Fei
    Amici, Fabrizio
    Attina, Primo
    Bachetti, Matteo
    Brienza, Daniele
    Centrone, Mauro
    Costa, Enrico
    Del Monte, Ettore
    Di Cosimo, Sergio
    Di Persio, Giuseppe
    Evangelista, Yuri
    Ferrazzoli, Riccardo
    Loffredo, Pasqualino
    Perri, Matteo
    Pilia, Maura
    Puccetti, Simonetta
    Ratheesh, Ajay
    Rubini, Alda
    Santoli, Francesco
    Scalise, Emanuele
    Trois, Alessio
    ASTROPARTICLE PHYSICS, 2022, 136
  • [16] SPECIFICATION AND CALIBRATION OF MONITORING EQUIPMENT
    MCCARTHY, JP
    PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (01): : 178 - 178
  • [17] Equipment calibration and quality control
    Carter, P.W.
    Engineering Science and Education Journal, 1995, 4 (05) : 207 - 210
  • [18] Calibration of crop protection equipment
    Bonds, Jane
    Langenakens, Jan
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [19] HIRDLS monochromator calibration equipment
    Hepplewhite, CL
    Barnett, JJ
    Djotni, K
    Whitney, JG
    Bracken, J
    Wolfenden, R
    Row, F
    Palmer, CWP
    Watkins, REJ
    Knight, RJ
    Gray, P
    Hammond, G
    INFRARED SPACEBORNE REMOTE SENSING XI, 2003, 5152 : 205 - 213
  • [20] Equipment for the calibration of squareness standards
    Hemming, Bjorn
    Korhonen, Antti
    Palosuo, Ilkka
    Lassila, Antti
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (09)