Experimental investigation of neural network estimator and transfer learning techniques for K-edge spectral CT imaging

被引:15
|
作者
Zimmerman, Kevin C. [1 ]
Sharma, Gayatri [1 ]
Parchur, Abdul Kareem [1 ]
Joshi, Amit [1 ]
Schmidt, Taly Gilat [1 ]
机构
[1] Marquette Univ, Med Coll Wisconsin, Dept Biomed Engn, Milwaukee, WI 53233 USA
关键词
contrast agent; machine learning; material decomposition; photon-counting; spectral CT; CONTRAST AGENTS; COMPUTED-TOMOGRAPHY; FEASIBILITY; EFFICIENT;
D O I
10.1002/mp.13946
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Spectral computed tomography (CT) material decomposition algorithms require accurate physics-based models or empirically derived models. This study investigates a machine learning algorithm and transfer learning techniques for Spectral CT imaging of K-edge contrast agents using simulated and experimental measurements. Methods A feed forward multilayer perceptron was implemented and trained on data acquired using a step wedge phantom containing acrylic, aluminum, and gadolinium materials. The neural network estimator was evaluated by scanning a rod phantom with varying dilutions of gadolinium oxide nanoparticles and by scanning a rat leg specimen with injected nanoparticles on a bench-top photon-counting computed tomography system. The algorithm decomposed each spectral projection measurement into path lengths of acrylic and aluminum and mass lengths of gadolinium. Each basis material sinogram was reconstructed into basis material images using filtered backprojection. Machine learning techniques of data standardization, transfer learning from aggregated pixel data, and transfer learning from simulations were investigated to improve image quality. The algorithm was compared to a previously published empirical method based on a linear approximation and calibration error look-up tables. Results The combined transfer learning techniques did not improve quantification in the rod phantom and provided only a small qualitative improvement in ring artifacts. Transfer learning from aggregated pixel data and from simulations improved the qualitative image quality of the rat specimen, for which the calibration data were limited. Transfer learning from aggregated pixel data and simulations estimated 3.26, 6.26, and 12.45 mg/mL Gd concentrations compared to true 2.72, 5.44, and 10.88 mg/mL concentrations in the rod phantom. Additionally, the neural networks were able to separate the soft tissue, bone, and gadolinium nanoparticles of the ex vivo rat leg specimen into the different basis images. Conclusions The results demonstrate that empirical K-edge imaging from calibration measurements using machine learning and transfer learning is possible without explicit models of material attenuations, incident spectra, or the detector response.
引用
收藏
页码:541 / 551
页数:11
相关论文
共 50 条
  • [1] Optimization of K-edge imaging with spectral CT
    He, Peng
    Wei, Biao
    Cong, Wenxiang
    Wang, Ge
    MEDICAL PHYSICS, 2012, 39 (11) : 6572 - 6579
  • [2] Spectral K-edge subtraction imaging
    Zhu, Y.
    Samadi, N.
    Martinson, M.
    Bassey, B.
    Wei, Z.
    Belev, G.
    Chapman, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (10): : 2485 - 2503
  • [3] Optimization of K-edge imaging with spectral CT (vol 39, pg 6572, 2012)
    He, Peng
    Wei, Biao
    Cong, Wenxiang
    Wang, Ge
    MEDICAL PHYSICS, 2013, 40 (01)
  • [4] K-edge Imaging with a Photon Counting CT System
    Matsumoto, Mariko
    Kaibuki, Futoshi
    Ogawa, Koichi
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [5] Spectral CT Using Multiple Balanced K-Edge Filters
    Rakvongthai, Yothin
    Worstell, William
    El Fakhri, Georges
    Bian, Junguo
    Lorsakul, Auranuch
    Ouyang, Jinsong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (03) : 740 - 747
  • [6] A Monte Carlo software bench for simulation of spectral k-edge CT imaging: Initial results
    Nasirudin, Radin A.
    Penchev, Petar
    Mei, Kai
    Rummeny, Ernst J.
    Fiebich, Martin
    Noel, Peter B.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (04): : 398 - 405
  • [7] K-edge ratio method for identification of multiple nanoparticulate contrast agents by spectral CT imaging
    Ghadiri, H.
    Ay, M. R.
    Shiran, M. B.
    Soltanian-Zadeh, H.
    Zaidi, H.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1029):
  • [8] Spectral K-edge subtraction imaging of experimental non-radioactive barium uptake in bone
    Panahifar, Arash
    Samadi, Nazanin
    Swanston, Treena M.
    Chapman, L. Dean
    Cooper, David M. L.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12): : 1765 - 1770
  • [9] A spectral CT technique using balanced K-edge filter set
    Rakvongthai, Yothin
    Worstell, William
    El Fakhri, Georges
    Ouyang, Jinsong
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [10] Feasibility of improving vascular imaging in the presence of metallic stents using spectral photon counting CT and K-edge imaging
    Monica Sigovan
    Salim Si-Mohamed
    Daniel Bar-Ness
    Julia Mitchell
    Jean-Baptiste Langlois
    Philippe Coulon
    Ewald Roessl
    Ira Blevis
    Michal Rokni
    Gilles Rioufol
    Philippe Douek
    Loic Boussel