A Monte Carlo software bench for simulation of spectral k-edge CT imaging: Initial results

被引:5
|
作者
Nasirudin, Radin A. [1 ]
Penchev, Petar [2 ]
Mei, Kai [1 ]
Rummeny, Ernst J. [1 ]
Fiebich, Martin [2 ]
Noel, Peter B. [1 ]
机构
[1] Tech Univ Munich, Dept Diagnost & Intervent Radiol, D-80290 Munich, Germany
[2] Univ Appl Sci, Inst Med Phys & Radiat Protect, Giessen, Germany
来源
关键词
Monte Carlo simulation; Spectral CT; Photon-counting detectors; Material decomposition; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-RADIOLOGY; RAY; DETECTOR;
D O I
10.1016/j.ejmp.2015.03.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Spectral Computed Tomography (SCT) systems equipped with photon counting detectors (PCD) are clinically desired, since such systems provide not only additional diagnostic information but also radiation dose reductions by a factor of two or more. The current unavailability of clinical PCDs makes a simulation of such systems necessary. Methods: In this paper, we present a Monte Carlo-based simulation of a SCT equipped with a PCD. The aim of this development is to facilitate research on potential clinical applications. Our MC simulator takes into account scattering interactions within the scanned object and has the ability to simulate scans with and without scatter and a wide variety of imaging parameters. To demonstrate the usefulness of such a MC simulator for development of SCT applications, a phantom with contrast targets covering a wide range of clinically significant iodine concentrations is simulated. With those simulations the impact of scatter and exposure on image quality and material decomposition results is investigated. Results: Our results illustrate that scatter radiation plays a significant role in visual as well as quantitative results. Scatter radiation can reduce the accuracy of contrast agent concentration by up to 15%. Conclusions: We present a reliable and robust software bench for simulation of SCTs equipped with PCDs. (C) 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:398 / 405
页数:8
相关论文
共 50 条
  • [1] Optimization of K-edge imaging with spectral CT
    He, Peng
    Wei, Biao
    Cong, Wenxiang
    Wang, Ge
    MEDICAL PHYSICS, 2012, 39 (11) : 6572 - 6579
  • [2] Evaluation of gold K-edge imaging using spectral computed tomography with a photon-counting detector: A Monte Carlo simulation study
    Kang, Sooncheol
    Eom, Jisoo
    Kim, Burnyoung
    Lee, Seungwan
    OPTIK, 2017, 140 : 253 - 260
  • [3] Spectral K-edge subtraction imaging
    Zhu, Y.
    Samadi, N.
    Martinson, M.
    Bassey, B.
    Wei, Z.
    Belev, G.
    Chapman, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (10): : 2485 - 2503
  • [4] Optimization of K-edge imaging with spectral CT (vol 39, pg 6572, 2012)
    He, Peng
    Wei, Biao
    Cong, Wenxiang
    Wang, Ge
    MEDICAL PHYSICS, 2013, 40 (01)
  • [5] K-edge Imaging with a Photon Counting CT System
    Matsumoto, Mariko
    Kaibuki, Futoshi
    Ogawa, Koichi
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [6] Feasibility of Photon-counting K-edge Imaging in X-ray and Computed Tomographic Systems: Monte Carlo Simulation Studies
    Lee, Seung-Wan
    Choi, Yu-Na
    Cho, Hyo-Min
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (04) : 2833 - 2839
  • [7] Spectral CT Using Multiple Balanced K-Edge Filters
    Rakvongthai, Yothin
    Worstell, William
    El Fakhri, Georges
    Bian, Junguo
    Lorsakul, Auranuch
    Ouyang, Jinsong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (03) : 740 - 747
  • [8] K-edge ratio method for identification of multiple nanoparticulate contrast agents by spectral CT imaging
    Ghadiri, H.
    Ay, M. R.
    Shiran, M. B.
    Soltanian-Zadeh, H.
    Zaidi, H.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1029):
  • [9] Experimental investigation of neural network estimator and transfer learning techniques for K-edge spectral CT imaging
    Zimmerman, Kevin C.
    Sharma, Gayatri
    Parchur, Abdul Kareem
    Joshi, Amit
    Schmidt, Taly Gilat
    MEDICAL PHYSICS, 2020, 47 (02) : 541 - 551
  • [10] A spectral CT technique using balanced K-edge filter set
    Rakvongthai, Yothin
    Worstell, William
    El Fakhri, Georges
    Ouyang, Jinsong
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033