Experimental investigation of neural network estimator and transfer learning techniques for K-edge spectral CT imaging

被引:15
|
作者
Zimmerman, Kevin C. [1 ]
Sharma, Gayatri [1 ]
Parchur, Abdul Kareem [1 ]
Joshi, Amit [1 ]
Schmidt, Taly Gilat [1 ]
机构
[1] Marquette Univ, Med Coll Wisconsin, Dept Biomed Engn, Milwaukee, WI 53233 USA
关键词
contrast agent; machine learning; material decomposition; photon-counting; spectral CT; CONTRAST AGENTS; COMPUTED-TOMOGRAPHY; FEASIBILITY; EFFICIENT;
D O I
10.1002/mp.13946
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Spectral computed tomography (CT) material decomposition algorithms require accurate physics-based models or empirically derived models. This study investigates a machine learning algorithm and transfer learning techniques for Spectral CT imaging of K-edge contrast agents using simulated and experimental measurements. Methods A feed forward multilayer perceptron was implemented and trained on data acquired using a step wedge phantom containing acrylic, aluminum, and gadolinium materials. The neural network estimator was evaluated by scanning a rod phantom with varying dilutions of gadolinium oxide nanoparticles and by scanning a rat leg specimen with injected nanoparticles on a bench-top photon-counting computed tomography system. The algorithm decomposed each spectral projection measurement into path lengths of acrylic and aluminum and mass lengths of gadolinium. Each basis material sinogram was reconstructed into basis material images using filtered backprojection. Machine learning techniques of data standardization, transfer learning from aggregated pixel data, and transfer learning from simulations were investigated to improve image quality. The algorithm was compared to a previously published empirical method based on a linear approximation and calibration error look-up tables. Results The combined transfer learning techniques did not improve quantification in the rod phantom and provided only a small qualitative improvement in ring artifacts. Transfer learning from aggregated pixel data and from simulations improved the qualitative image quality of the rat specimen, for which the calibration data were limited. Transfer learning from aggregated pixel data and simulations estimated 3.26, 6.26, and 12.45 mg/mL Gd concentrations compared to true 2.72, 5.44, and 10.88 mg/mL concentrations in the rod phantom. Additionally, the neural networks were able to separate the soft tissue, bone, and gadolinium nanoparticles of the ex vivo rat leg specimen into the different basis images. Conclusions The results demonstrate that empirical K-edge imaging from calibration measurements using machine learning and transfer learning is possible without explicit models of material attenuations, incident spectra, or the detector response.
引用
收藏
页码:541 / 551
页数:11
相关论文
共 50 条
  • [21] The Feasibility of Accurate Stent Visualization With Photon-Counting Detector CT and K-Edge Imaging
    Richtsmeier, Devon
    Rodesch, Pierre-Antoine
    Iniewski, Kris
    Siu, William
    Bazalova-Carter, Magdalena
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (07) : 712 - 718
  • [22] Increased separability of K-edge nanoparticles by photon-counting detectors for spectral micro-CT
    Getzin, Matthew
    Garfield, Josephine J.
    Rundle, David S.
    Kruger, Uwe
    Butler, Anthony P. H.
    Gkikas, Manos
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (05) : 707 - 726
  • [23] Investigation of the mica x-ray absorption near-edge structure spectral features at the Al K-edge
    Wu, ZY
    Marcelli, A
    Cibin, G
    Mottana, A
    Della Ventura, G
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2003, 15 (41) : 7139 - 7148
  • [24] In Vivo Molecular K-Edge Imaging of Atherosclerotic Plaque Using Photon-counting CT
    Si-Mohamed, Salim A.
    Sigovan, Monica
    Hsu, Jessica C.
    Tatard-Leitman, Valerie
    Chalabreysse, Lara
    Naha, Pratap C.
    Garrivier, Thibaut
    Dessouky, Riham
    Carnaru, Miruna
    Boussel, Loic
    Cormode, David P.
    Douek, Philippe C.
    RADIOLOGY, 2021, 300 (01) : 98 - 107
  • [25] Second generation gold nanobeacons for robust K-edge imaging with multi-energy CT
    Schirra, Carsten O.
    Senpan, Angana
    Roessl, Ewald
    Thran, Axel
    Stacy, Allen J.
    Wu, Lina
    Proksa, Roland
    Pan, Dipanjan
    JOURNAL OF MATERIALS CHEMISTRY, 2012, 22 (43) : 23071 - 23077
  • [26] In vivo Gd-nanoparticles image-based quantification with SPECT and k-edge spectral CT
    Kochebina, O.
    Halty, A.
    Taleb, J.
    Kryza, D.
    Janier, M.
    Sadr, A. Bani
    Mory, C.
    Bar-Ness, D.
    Douek, P.
    Si-Mohamed, S.
    Baudier, T.
    Rit, S.
    Sarrut, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S292 - S292
  • [27] Experimental spectral measurements of heavy K-edge filtered beams for x-ray computed mammotomography
    Crotty, D. J.
    McKinley, R. L.
    Tornai, M. P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (03): : 603 - 616
  • [28] Experimental spectral measurements of heavy K-edge filtered beams for x-ray computed mammotomography
    Crotty, Dominic J.
    McKinley, Randolph L.
    Tornai, Martin P.
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [29] Simultaneous X-ray fluorescence and K-edge CT imaging with photon-counting detectors
    Li, Liang
    Li, Ruizhe
    Zhang, Siyuan
    Chen, Zhiqiang
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [30] K-Edge Imaging Using a Gold Nanoparticle Contrast Agent and a CT System with Photon Counting Detectors
    Alivov, Y.
    Le, H.
    Molloi, S.
    MEDICAL PHYSICS, 2010, 37 (06)