Comparative Study of the Diagnostic Ability of Magnetic Resonance Imaging and Multidetector Row Computed Tomography for Anomalous Pancreaticobiliary Ductal Junction

被引:3
|
作者
Nakamoto, Atsushi [1 ]
Kim, Tonsok [1 ]
Hori, Masatoshi [1 ]
Onishi, Hiromitsu [1 ]
Nakaya, Yasuhiro [2 ]
Tsuboyama, Takahiro [1 ]
Tatsumi, Mitsuaki [1 ]
Tomoda, Kaname [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Radiol, Suita, Osaka 5650871, Japan
[2] Nishinomiya Municipal Cent Hosp, Dept Radiol, Nishinomiya, Hyogo, Japan
关键词
anomalous pancreaticobiliary ductal junction; MR imaging; multidetector row CT; MULTIPLANAR REFORMATTED IMAGES; CHOLEDOCHAL CYSTS; MR CHOLANGIOPANCREATOGRAPHY; CT; VISUALIZATION; MALJUNCTION; REFLUX; UNION;
D O I
10.1097/RCT.0b013e3181e23ff2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the diagnostic performance of magnetic resonance (MR) imaging and multidetector row computed tomography (MDCT) for an anomalous pancreaticobiliary ductal junction (PBJ). Methods: This study included 26 patients who underwent MR imaging, MDCT, and endoscopic retrograde cholangiopancreatography. Seventeen of the patients were diagnosed by endoscopic retrograde cholangiopancreatography as having an anomalous PBJ. Three radiologists independently reviewed MR images alone, contrast-enhanced CT images alone, and MR images and CT images combined. Receiver operating characteristic curve analysis was used to compare diagnostic capabilities. Results: The mean area under the receiver operating characteristic curve (Az [95% confidence interval]) was 0.75 (0.73-0.77) for MR imaging alone, 0.79 (0.70-0.89) for CT alone, and 0.84 (0.82-0.86) for the 2 modalities combined. Only between the combination and MR imaging alone was there significant difference in Az value (P < 0.05). Conclusions: The diagnostic performance of MR imaging and MDCT was equivalent for an anomalous PBJ. The addition of MDCT to MR imaging improved the diagnostic performance.
引用
收藏
页码:725 / 731
页数:7
相关论文
共 50 条
  • [31] The emerging role of magnetic resonance imaging and multidetector computed tomography in the diagnosis of dilated cardiomyopathy
    Slavich, Massimo
    Florian, Anca
    Bogaert, Jan
    INSIGHTS INTO IMAGING, 2011, 2 (04): : 453 - 469
  • [32] Multidetector Computed Tomography Diagnosis of Fusion of Pancreas and Spleen Confirmed by Magnetic Resonance Imaging
    Balli, Omur
    Karcaaltincaba, Musturay
    Karaosmanoglu, Devrim
    Akata, Deniz
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (02) : 291 - 292
  • [33] Magnetic resonance imaging of pulmonary infection in immunocompromised children: comparison with multidetector computed tomography
    H. Nursun Ozcan
    Ayşegul Gormez
    Yasemin Ozsurekci
    Jale Karakaya
    Berna Oguz
    Sule Unal
    Mualla Cetin
    Mehmet Ceyhan
    Mithat Haliloglu
    Pediatric Radiology, 2017, 47 : 146 - 153
  • [34] Update on Cardiac Imaging Techniques: Echocardiography, Cardiac Magnetic Resonance, and Multidetector Computed Tomography
    Velasco del Castilloa, Sonia
    Aguilar Torres, Rio
    Pare Bardera, Juan C.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2009, 62 : 129 - 150
  • [35] Automated vs. manual assessment of left ventricular function in cardiac multidetector row computed tomography:: comparison with magnetic resonance imaging
    Mahnken, AH
    Mühlenbruch, G
    Koos, R
    Stanzel, S
    Busch, PS
    Niethammer, M
    Günther, RW
    Wildberger, JE
    EUROPEAN RADIOLOGY, 2006, 16 (07) : 1416 - 1423
  • [36] Multidetector row computed tomography and magnetic resonance imaging can accurately estimate aortic valve area as compared to transthoracic and transesophageal echocardiography
    Pouleur, AC
    de Waroux, JBLP
    Belge, B
    Pasquet, A
    Gerber, B
    Vanoverschelde, JL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 128A - 128A
  • [37] Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography - Comparison with cine magnetic resonance imaging
    Belge, Benedicte
    Coche, Emmanuel
    Pasquet, Agnes
    Vanoverschelde, Jean-Louis J.
    Gerber, Bernhard L.
    EUROPEAN RADIOLOGY, 2006, 16 (07) : 1424 - 1433
  • [38] In vivo 16-slice, multidetector-row computed tomography for the assessment of experimental atherosclerosis - Comparison with magnetic resonance imaging and histopathology
    Viles-Gonzalez, JF
    Poon, M
    Sanz, J
    Rius, T
    Nikolaou, K
    Fayad, ZA
    Fuster, V
    Badimon, JJ
    CIRCULATION, 2004, 110 (11) : 1467 - 1472
  • [39] 16-slice multidetector-row computed tomography and magnetic resonance imaging for the in vivo and noninvasive assessment of vessel areas and diameters
    Viles-Gonzalez, JF
    Poon, M
    Sanz, J
    Rius, T
    Nikolaou, K
    Fayad, ZA
    Fuster, V
    Badimon, JJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 314A - 314A
  • [40] Automated vs. manual assessment of left ventricular function in cardiac multidetector row computed tomography: comparison with magnetic resonance imaging
    Andreas H. Mahnken
    Georg Mühlenbruch
    Ralf Koos
    Sven Stanzel
    Petra Simone Busch
    Mathias Niethammer
    Rolf W. Günther
    Joachim E. Wildberger
    European Radiology, 2006, 16 : 1416 - 1423