Development and initial evaluation of a finite element model of the pediatric craniocervical junction

被引:15
|
作者
Phuntsok, Rinchen [1 ,2 ]
Mazur, Marcus D. [3 ]
Ellis, Benjamin J. [1 ,2 ]
Ravindra, Vijay M. [3 ]
Brookmeyer, Douglas L. [3 ]
机构
[1] Univ Utah, Dept Bioengn, Salt Lake City, UT 84113 USA
[2] Univ Utah, Sci Comp & Imaging Inst, Salt Lake City, UT 84113 USA
[3] Univ Utah, Dept Neurosurg, Primary Childrens Hosp, Div Pediat Neurosurg, 100 Mario Capecchi Dr, Salt Lake City, UT 84113 USA
关键词
pediatric; craniocervical junction; finite element modeling; spinal biomechanics; spine; UPPER CERVICAL-SPINE; MECHANICAL-PROPERTIES; TRANSVERSE LIGAMENTS; VALIDATION; BIOMECHANICS; INSTRUMENTATION; SENSITIVITY; CARTILAGE; RESPONSES; FIXATION;
D O I
10.3171/2015.8.PEDS15334
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE There is a significant deficiency in understanding the biomechanics of the pediatric craniocervical junction (CCJ) (occiput C2), primarily because of a lack of human pediatric cadaveric tissue and the relatively small number of treated patients. To overcome this deficiency, a finite element model (FEM) of the pediatric CCJ was created using pediatric geometry and parameterized adult material properties. The model was evaluated under the physiological range of motion (ROM) for flexion-extension, axial rotation, and lateral bending and under tensile loading. METHODS This research utilizes the FEM method, which is a numerical solution technique for discretizing and analyzing systems. The FEM method has been widely used in the field of biomechanics. A CT scan of a 13-month-old female patient was used to create the 3D geometry and surfaces of the FEM model, and an open-source FEM software suite was used to apply the material properties and boundary and loading conditions and analyze the model. The published adult ligament properties were reduced to 50%, 25%, and 10% of the original stiffness in various iterations of the model, and the resulting ROMs for flexion-extension, axial rotation, and lateral bending were compared. The flexion-extension ROMs and tensile stiffness that were predicted by the model were evaluated using previously published experimental measurements from pediatric cadaveric tissues. RESULTS The model predicted a ROM within 1 standard deviation of the published pediatric ROM data for flexion extension at 10% of adult ligament stiffness. The model's response in terms of axial tension also coincided well with published experimental tension characterization data. The model behaved relatively stiffer in extension than in flexion. The axial rotation and lateral bending results showed symmetric ROM, but there are currently no published pediatric experimental data available for comparison. The model predicts a relatively stiffer ROM in both axial rotation and lateral bending in comparison with flexion-extension. As expected, the flexion-extension, axial rotation, and lateral bending ROMs increased with the decrease in ligament stiffness. CONCLUSIONS An FEM of the pediatric CCJ was created that accurately predicts flexion-extension ROM and axial force displacement of occiput C2 when the ligament material properties are reduced to 10% of the published adult ligament properties. This model gives a reasonable prediction of pediatric cervical spine ligament stiffness, the relationship between flexion-extension ROM, and ligament stiffness at the CCJ. The creation of this model using open-source software means that other researchers will be able to use the model as a starting point for research.
引用
收藏
页码:497 / 503
页数:7
相关论文
共 50 条
  • [21] Development and Validation of Finite Element Analysis Model (FEM) of Craniovertebral Junction Experimental Biomechanical Cadaveric Study
    Gupta, Deepak
    Zubair, Mohd
    Lalwani, Sanjeev
    Gamanagatti, Shiva
    Roy, Tara Sankar
    Mukherjee, Sudipto
    Kale, Shashank Sharad
    SPINE, 2020, 45 (16) : E978 - E988
  • [22] Erratum to: Development, Validation, and Application of a Parametric Pediatric Head Finite Element Model for Impact Simulations
    Zhigang Li
    Jingwen Hu
    Matthew P. Reed
    Jonathan D. Rupp
    Carrie N. Hoff
    Jinhuan Zhang
    Bo Cheng
    Annals of Biomedical Engineering, 2013, 41 : 215 - 220
  • [23] Evaluation of the Normal Craniocervical Junction Craniometry in 137 Asymptomatic Patients
    Al-Dwairy, Salem
    Fataftah, Jehad
    Al-Mousa, Alaa
    Ejjo, Mohammad Z.
    Albakri, Khaled
    Mohammad, Altarawneh
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2023, 41 (01): : 216 - 224
  • [24] Numerical Evaluation Using the Finite Element Method on Frontal Craniocervical Impact Directed at Intervertebral Disc Wear
    Trejo-Enriquez, Alfonso
    Urriolagoitia-Sosa, Guillermo
    Romero-Angeles, Beatriz
    Garcia-Laguna, Miguel Angel
    Guzman-Baeza, Martin
    Martinez-Reyes, Jacobo
    Rojas-Castrejon, Yonatan Yael
    Gallegos-Funes, Francisco Javier
    Patino-Ortiz, Julian
    Urriolagoitia-Calderon, Guillermo Manuel
    APPLIED SCIENCES-BASEL, 2023, 13 (21):
  • [25] Fuzzy evaluation of dynamics finite element model
    College of Aerospace Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
    Nanjing Hangkong Hangtian Daxue Xuebao, 2006, 3 (367-372):
  • [26] Evaluation of the exophthalmia reduction with a finite element model
    Luboz, V
    Pedrono, A
    Boutault, F
    Swider, P
    Payan, Y
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 1123 - 1123
  • [27] Finite Element Analysis Model of a PV Junction Box for Thermal Assessment
    Rane, Karan
    Verma, Navni
    Contractor, Ardeshir
    Shiradkar, Narendra
    2020 47TH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2020, : 2757 - 2759
  • [28] Development of a mobility scooter finite element model
    Li, Hongyu
    Chirwa, E. C.
    INTERNATIONAL JOURNAL OF CRASHWORTHINESS, 2015, 20 (03) : 217 - 229
  • [29] Development of a Finite Element Model of Decompressive Craniectomy
    Fletcher, Tim L.
    Kolias, Angelos G.
    Hutchinson, Peter J. A.
    Sutcliffe, Michael P. F.
    PLOS ONE, 2014, 9 (07):
  • [30] Development of a Human Neck Finite Element Model
    Zhang, Jianguo
    Wang, Fang
    Xue, Qiang
    Song, Haiyan
    Li, Jun
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 787 - 790