Comparison of Direct and Video Laryngoscopes during Different Airway Scenarios Performed by Experienced Paramedics: A Randomized Cross-Over Manikin Study

被引:6
|
作者
Ruetzler, Kurt [1 ,2 ]
Szarpak, Lukasz [3 ]
Smereka, Jacek [4 ]
Dabrowski, Marek [5 ]
Bialka, Szymon [6 ]
Mosteller, Lauretta [2 ]
Szarpak, Agnieszka [7 ]
Ludwin, Kobi [7 ]
Wojewodzka-Zelezniakowicz, Marzena [8 ]
Ladny, Jerzy Robert [8 ]
机构
[1] Cleveland Clin, Dept Gen Anesthesiol, Inst Anesthesiol, Cleveland, OH 44106 USA
[2] Cleveland Clin, Dept Outcomes Res, Inst Anesthesiol, Cleveland, OH 44106 USA
[3] Lazarski Univ, Med Simulat Ctr, Swieradowska 43, Warsaw, Poland
[4] Wroclaw Med Univ, Dept Emergency Med Serv, Parkowa 34, Wroclaw, Poland
[5] Poznan Univ Med Sci, Chair & Dept Med Educ, Dabrowskiego 12, Poznan, Poland
[6] Med Univ Silesia, Dept Anesthesiol Intens Care & Emergency Med, 3 Go Maja 13-15, Zabrze, Poland
[7] Polish Soc Disaster Med, Swieradowska 43, Warsaw, Poland
[8] Med Univ Bialystok, Dept Emergency Med, Szpitalna 37, Bialystok, Poland
关键词
TRACHEAL INTUBATION; MCGRATH MAC; CPR;
D O I
10.1155/2020/5382739
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction. Airway management plays an essential role in anaesthesia practice, during both elective and urgent surgery procedures and emergency medicine. Aim. The aim of the study was to compare Macintosh laryngoscope (MAC), McGrath, and TruView PCD in 5 separate airway management scenarios. Methods. This prospective cross-over simulation study involved 93 paramedics. All paramedics performed intubation using direct laryngoscope (MAC), McGrath, and TruView PCD video laryngoscopes. The study was performed in 5 different scenarios: (A) normal airway, (B) tongue oedema, (C) pharyngeal obstruction, (D) cervical collar stabilization with tongue oedema, and (E) cervical collar stabilization with pharyngeal obstruction. Results. In scenario A, the success rate was 99% with MAC, 100% with McGrath, and 94% with PCD. Intubation time was 17 s (IQR: 16-21) for MAC, 18 s (IQR: 16-21) for McGrath, and 27 s (IQR: 23-34) for PCD. In scenario B, the success rate was 61% with MAC, 97% with McGrath, and 97% with PCD (p<0.001). Intubation time was 44 s (IQR: 24-46) for MAC, 22 s (IQR: 20-27) for McGrath, and 39 s (IQR: 30-57) for PCD. In scenario C, the success rate with MAC was 74%, 97% with McGrath, and 72% with PCD (p<0.001). Intubation time was 21 s (IQR: 19-29) for MAC, 18 s (IQR: 18-24.5) for McGrath, and 30 s (IQR: 23-39) for PCD. In scenario D, the success rate with MAC was 32%, 69% with McGrath, and 58% with PCD (p<0.001). Intubation time was 26 s (IQR: 20-29) for MAC, 26 s (IQR: 20-29) for McGrath, and 45 s (IQR: 33-56) for PCD. In scenario E, the success rate with MAC was 32%, but 64% with McGrath and 62% with PCD (p<0.001). Intubation time was 28 s (IQR: 25-39) for MAC, 19 s (IQR: 18-26) for McGrath, and 34 s (IQR: 27-45) for PCD. Conclusions. The McGrath video laryngoscope proved better than Truview PCD and direct intubation with Macintosh laryngoscope in terms of success rate, duration of first intubation attempt, number of intubation attempts, Cormack-Lehane grade, percentage of glottis opening (POGO score), number of optimization manoeuvres, severity of dental compression, and ease of use.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Selective intubation with endotracheal tube introducer in difficult airway: A randomized, prospective, cross-over study
    Ozerol, Hakan
    Sanci, Emre
    Karakayali, Onur
    Aydin, Erdem
    Halhalli, Huseyin Cahit
    TURKISH JOURNAL OF EMERGENCY MEDICINE, 2021, 21 (04): : 205 - 209
  • [42] Esophageal balloon calibration during Sigh: A physiologic, randomized, cross-over study
    Cammarota, Gianmaria
    Santangelo, Erminio
    Lauro, Gianluigi
    Verdina, Federico
    Boniolo, Ester
    De Vita, Nello
    Tarquini, Riccardo
    Spinelli, Elena
    Garofalo, Eugenio
    Bruni, Andrea
    Zanoni, Marta
    Messina, Antonio
    Pesenti, Antonio
    Della Corte, Francesco
    Navalesi, Paolo
    Vaschetto, Rosanna
    Mauri, Tommaso
    JOURNAL OF CRITICAL CARE, 2021, 61 : 125 - 132
  • [43] Comparison of High-Flow Humidified Oxygen With Conventional Continuous Positive Airway Pressure in Nonventilated Lungs During Thoracic Surgery: A Randomized Cross-Over Study
    Sawasdiwipachai, Prasert
    Weerayutwattana, Ratchaya
    Thongcharoen, Punnarerk
    Suksompong, Sirilak
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (10) : 2945 - 2951
  • [44] Comparison of the UEScope videolaryngoscope with the Macintosh laryngoscope during simulated cardiopulmonary resuscitation: A randomized, cross-over, multi-center manikin study (vol 97, e12085, 2018)
    Szarpak, L.
    Madziala, A.
    Czekajlo, M.
    MEDICINE, 2019, 98 (36)
  • [45] Kendo Protective Equipment Prevents Quick Access for Resuscitation During Sudden Cardiac Arrest: A Cross-Over Manikin Study
    Tanaka, Shota
    Ueta, Hiroki
    Sagisaka, Ryo
    Sakanashi, Shuji
    Hara, Takahiro
    Tanaka, Hideharu
    INTERNATIONAL JOURNAL OF ATHLETIC THERAPY & TRAINING, 2020, 25 (04): : 197 - 202
  • [46] Direct intraperitoneal insemination compared to intrauterine insemination in superovulated cycles: A randomized cross-over study
    Tiemessen, CHJ
    Bots, RSGM
    Peeters, MF
    Evers, JLH
    GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 1997, 44 (03) : 149 - 152
  • [47] The pharmacokinetics and metabolism of ifosfamide during bolus and infusional administration: a randomized cross-over study
    JM Singer
    JM Hartley
    C Brennan
    PW Nicholson
    RL Souhami
    British Journal of Cancer, 1998, 77 : 978 - 984
  • [48] The pharmacokinetics and metabolism of ifosfamide during bolus and infusional administration: a randomized cross-over study
    Singer, JM
    Hartley, JM
    Brennan, C
    Nicholson, PW
    Souhami, RL
    BRITISH JOURNAL OF CANCER, 1998, 77 (06) : 978 - 984
  • [49] Efficacy of various types of laryngoscope (direct, Pentax Airway Scope and GlideScope) for endotracheal intubation in various cervical immobilisation scenarios: a randomised cross-over simulation study
    Kim, Jong Won
    Lee, Kyeong Ryong
    Hong, Dae Young
    Baek, Kwang Je
    Lee, Young Hwan
    Park, Sang O.
    BMJ OPEN, 2016, 6 (10):
  • [50] REMOVAL OF DIFFERENT CLASSES OF UREMIC TOXINS IN APD VS CAPD: A RANDOMIZED CROSS-OVER STUDY
    Eloot, Sunny
    Vanholder, Raymond
    Dequidt, Clement
    Van Biesen, Wim
    PERITONEAL DIALYSIS INTERNATIONAL, 2015, 35 (04): : 436 - 442