Low-noise electronics for high-resolution CdZnTe and CdTe X-ray detection systems

被引:3
|
作者
Niemela, A [1 ]
机构
[1] METOREX INT OY,ESPOO 02201,FINLAND
来源
JOURNAL DE PHYSIQUE IV | 1996年 / 6卷 / C4期
关键词
D O I
10.1051/jp4:1996469
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
CdZnTe and CdTe detector performance can be significantly improved with low-noise electronics. The main sources of noise that broaden the spectrum peaks in a room-temperature system are incomplete charge collection and leakage current of the detector, and the feedback resistor of the preamplifier. The detector leakage current can be reduced by cooling the detector to about -30 degrees C. Normally, at these temperatures the leakage current of a small detector crystal drops to the picoampere level which enables the use of low-noise, pulsed-optical feedback preamplifiers instead of noisier resistive feedback preamplifiers. Also, because of lower leakage currents, it is possible to use higher bias voltages at low temperatures which is important for more efficient charge collection. This reduces spectrum background and peak tailing. Applying rise time discrimination circuitry to the linear amplifier reduces the tailing effect even further, especially at higher energies. By employing all these methods a number of Cd0.9Zn0.1Te, Cd0.8Zn0.2Te and PIN-structure CdTe detector crystals were tested at temperatures between -20 degrees C and -40 degrees C, and at best FWHM energy resolutions of 240 eV at the 5.9-keV line of Fe-55, 600 eV at the 59.5-keV line of Am-241, and 4.4 keV (0.7 %) at the 662-keV line of Cs-137 were obtained. These energy resolutions measured at room temperature with conventional methods are typically about 4 to 10 times poorer.
引用
收藏
页码:721 / 731
页数:11
相关论文
共 50 条
  • [41] A HIGH-RATE, LOW-NOISE, X-RAY SILICON STRIP DETECTOR SYSTEM
    LUDEWIGT, B
    JAKLEVIC, J
    KIPNIS, I
    ROSSINGTON, C
    SPIELER, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1037 - 1041
  • [42] Study of CdTe and CdZnTe detectors for X-ray computed tomography
    Ricq, S
    Glasser, F
    Garcin, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 534 - 543
  • [43] Low-noise multichannel ASIC for high count rate X-ray diffractometry applications
    Szczygiel, R.
    Grybos, P.
    Maj, P.
    Tsukiyama, A.
    Matsushita, K.
    Taguchi, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 229 - 232
  • [44] High-resolution X-ray holograph on the deck
    Bradley, David
    MATERIALS TODAY, 2014, 17 (03) : 105 - 106
  • [45] The Colibri High-Resolution X-ray Telescope
    Heyl, Jeremy
    Caiazzo, Ilaria
    Gallagher, Sarah
    Hoffman, Kelsey
    Safi-Harb, Samar
    SPACE TELESCOPES AND INSTRUMENTATION 2020: ULTRAVIOLET TO GAMMA RAY, 2021, 11444
  • [46] High-resolution X-ray spectra of quasars
    Kaspi, S
    INTERPLAY AMONG BLACK HOLES, STARS AND ISM IN GALACTIC NUCLEI, 2004, (222): : 41 - 44
  • [47] HIGH-RESOLUTION X-RAY TEXTURE GONIOMETRY
    VANDERPLUIJM, BA
    HO, NC
    PEACOR, DR
    JOURNAL OF STRUCTURAL GEOLOGY, 1994, 16 (07) : 1029 - 1032
  • [48] High-resolution imaging X-ray spectrometers
    Strüder, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 454 (01): : 73 - 113
  • [49] HIGH-RESOLUTION X-RAY CRYSTAL SPECTROGRAPHS
    KOPPEL, LN
    DELECKELS, J
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (09): : 1112 - 1112
  • [50] High-resolution X-ray spectroscopy of θ Carinae
    Naze, Y.
    Rauw, G.
    ASTRONOMY & ASTROPHYSICS, 2008, 490 (02) : 801 - 806