Low-noise electronics for high-resolution CdZnTe and CdTe X-ray detection systems

被引:3
|
作者
Niemela, A [1 ]
机构
[1] METOREX INT OY,ESPOO 02201,FINLAND
来源
JOURNAL DE PHYSIQUE IV | 1996年 / 6卷 / C4期
关键词
D O I
10.1051/jp4:1996469
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
CdZnTe and CdTe detector performance can be significantly improved with low-noise electronics. The main sources of noise that broaden the spectrum peaks in a room-temperature system are incomplete charge collection and leakage current of the detector, and the feedback resistor of the preamplifier. The detector leakage current can be reduced by cooling the detector to about -30 degrees C. Normally, at these temperatures the leakage current of a small detector crystal drops to the picoampere level which enables the use of low-noise, pulsed-optical feedback preamplifiers instead of noisier resistive feedback preamplifiers. Also, because of lower leakage currents, it is possible to use higher bias voltages at low temperatures which is important for more efficient charge collection. This reduces spectrum background and peak tailing. Applying rise time discrimination circuitry to the linear amplifier reduces the tailing effect even further, especially at higher energies. By employing all these methods a number of Cd0.9Zn0.1Te, Cd0.8Zn0.2Te and PIN-structure CdTe detector crystals were tested at temperatures between -20 degrees C and -40 degrees C, and at best FWHM energy resolutions of 240 eV at the 5.9-keV line of Fe-55, 600 eV at the 59.5-keV line of Am-241, and 4.4 keV (0.7 %) at the 662-keV line of Cs-137 were obtained. These energy resolutions measured at room temperature with conventional methods are typically about 4 to 10 times poorer.
引用
收藏
页码:721 / 731
页数:11
相关论文
共 50 条
  • [31] High-resolution pixelated CdZnTe detector prototype system for solar hard X-ray imager
    Shen Wang
    Jian-Hua Guo
    Yan Zhang
    Wei Chen
    Nuclear Science and Techniques, 2019, 30 (03) : 93 - 98
  • [32] High-resolution pixelated CdZnTe detector prototype system for solar hard X-ray imager
    Wang, Shen
    Guo, Jian-Hua
    Zhang, Yan
    Chen, Wei
    NUCLEAR SCIENCE AND TECHNIQUES, 2019, 30 (03)
  • [33] Low-noise and high-speed charge detection in high-resolution CCD image sensors
    Hynecek, J
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1997, 44 (10) : 1679 - 1688
  • [34] CdTe and CdZnTe room-temperature X-ray and gamma ray detectors and imaging systems
    Eisen, Y
    Shor, A
    SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 : 129 - 145
  • [35] High-resolution X-ray and γ-ray detection using cryogenic magnetic calorimeters
    Enss, C
    PHYSICA B, 2000, 280 (1-4): : 515 - 519
  • [36] A low-noise 64-channel front-end readout ASIC for CdZnTe detectors aimed to hard X-ray imaging systems
    Gan, B.
    Wei, T.
    Gao, W.
    Liu, H.
    Hu, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 816 : 53 - 61
  • [37] DUAL COLLIMATION ACQUISITION FOR HIGH-RESOLUTION, LOW-NOISE SPECT
    FLOYD, CE
    MUNLEY, MT
    TOURASSI, GD
    BOWSHER, JE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 784 - 788
  • [38] High-resolution x-ray diffraction and x-ray reflectivity studies of short-period CdTe/MnTe-superlattices
    Stangl, J
    Darhuber, AA
    Holy, V
    de Naurois, M
    Ferreira, S
    Faschinger, W
    Bauer, G
    JOURNAL OF CRYSTAL GROWTH, 1998, 184 : 105 - 108
  • [39] Advances in high-resolution CdTe and large volume CdZnTe detectors
    Arlt, R
    Ivanov, V
    Khusainov, A
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS, OPTICS, AND APPLICATIONS, 1997, 3115 : 76 - 89
  • [40] LOW-NOISE MICROCHANNEL PLATE DETECTORS FOR X-RAY ASTRONOMY
    GARCIA, MR
    CHAPPELL, JH
    MURRAY, SS
    FELLER, WB
    FRASER, GW
    X-RAY INSTRUMENTATION IN MEDICINE AND BIOLOGY, PLASMA PHYSICS, ASTROPHYSICS, AND SYNCHROTRON RADIATION, 1989, 1140 : 101 - 105