Low-noise electronics for high-resolution CdZnTe and CdTe X-ray detection systems

被引:3
|
作者
Niemela, A [1 ]
机构
[1] METOREX INT OY,ESPOO 02201,FINLAND
来源
JOURNAL DE PHYSIQUE IV | 1996年 / 6卷 / C4期
关键词
D O I
10.1051/jp4:1996469
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
CdZnTe and CdTe detector performance can be significantly improved with low-noise electronics. The main sources of noise that broaden the spectrum peaks in a room-temperature system are incomplete charge collection and leakage current of the detector, and the feedback resistor of the preamplifier. The detector leakage current can be reduced by cooling the detector to about -30 degrees C. Normally, at these temperatures the leakage current of a small detector crystal drops to the picoampere level which enables the use of low-noise, pulsed-optical feedback preamplifiers instead of noisier resistive feedback preamplifiers. Also, because of lower leakage currents, it is possible to use higher bias voltages at low temperatures which is important for more efficient charge collection. This reduces spectrum background and peak tailing. Applying rise time discrimination circuitry to the linear amplifier reduces the tailing effect even further, especially at higher energies. By employing all these methods a number of Cd0.9Zn0.1Te, Cd0.8Zn0.2Te and PIN-structure CdTe detector crystals were tested at temperatures between -20 degrees C and -40 degrees C, and at best FWHM energy resolutions of 240 eV at the 5.9-keV line of Fe-55, 600 eV at the 59.5-keV line of Am-241, and 4.4 keV (0.7 %) at the 662-keV line of Cs-137 were obtained. These energy resolutions measured at room temperature with conventional methods are typically about 4 to 10 times poorer.
引用
收藏
页码:721 / 731
页数:11
相关论文
共 50 条
  • [1] CMOS low-noise switched charge sensitive preamplifier for CdTe and CdZnTe X-ray detectors
    Jakobson, CG
    Nemirovsky, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (01) : 20 - 25
  • [2] CMOS low-noise switched charge sensitive preamplifier for CdTe and CdZnTe X-ray detectors
    Technion-Israel Inst of Technology, Haifa, Israel
    IEEE Trans Nucl Sci, 1 (20-25):
  • [3] High-resolution X-ray mapping of CdZnTe detectors
    Carini, G. A.
    Bolotnikov, A. E.
    Camarda, G. S.
    James, R. B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 120 - 124
  • [4] Optimization of low-noise read-out electronics for high energy resolution X-ray strip detectors
    Zubrzycka, W.
    Grybos, P.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (01):
  • [5] X-ray Imaging with ePix100a, a High-Speed, High-Resolution, Low-Noise Camera
    Blaj, G.
    Caragiulo, P.
    Dragone, A.
    Haller, G.
    Hasi, J.
    Kenney, C. J.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XVIII, 2016, 9968
  • [6] THE LOW-NOISE (HIGH-RESOLUTION) ELECTROCARDIOGRAM
    ELSHERIF, N
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1984, 6 (02) : 185 - 188
  • [7] CdTe and CdZnTe X-ray and gamma-ray detectors for imaging systems
    Eisen, Y
    Shor, A
    Mardor, I
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 1191 - 1198
  • [8] CdTe and CdZnTe X-ray and gamma-ray detectors for imaging systems
    Eisen, Y
    Shor, A
    Mardor, I
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3311 - 3319
  • [9] High-resolution p-i-n CdTe and CdZnTe X-ray detectors with cooling and rise-time discrimination
    Niemela, A
    Sipila, H
    Ivanov, VI
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1476 - 1480
  • [10] High-resolution p-i-n CdTe and CdZnTe x-ray detectors with cooling and rise-time discrimination
    Niemela, A
    Sipila, H
    Ivanov, VI
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 549 - 553