Electron transfer in amperometric biosensors

被引:0
|
作者
Polohova, Vladimira [1 ]
Snejdarkova, Maja [1 ]
机构
[1] Slovak Acad Sci, Inst Anim Biochem & Genet, Ivanka Pri Dunaji 90028, Slovakia
来源
CHEMICKE LISTY | 2008年 / 102卷 / 03期
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
At present direct electron transfer between an electrode and protein ranks among promising areas of biosensor research. This review focuses on current trends and methods in the development of third-generation amperometric biosensors. It describes the construction of the biosensors of three generations and enzyme immobilization techniques. The design of the electrode interface and biosensor architecture are essential in bioelectrocatalysis, fast electron transfer and electrode construction. Differences in the architectures usually reflect specific electron transfer mechanisms. In the second-generation biosensors, the preferred design consists of biosensors with mediators tightly bound in the active layer of the electrode surface. Attempts at the direct electron transfer employ techniques like self-assembled monolayers, conducting polymers, reconstitution of the prosthetic group and apoenzyme in active holoenzyme and integration of nanotechnology. Despite considerable efforts, no commercially available biosensors based on the direct electron transfer have been developed so far. Modem approaches such as redox proteins and enzymes with engineered electron pathways can make this type of biosensors commercially attractive.
引用
收藏
页码:173 / 182
页数:10
相关论文
共 50 条
  • [42] Graphene electrochemistry: Fabricating amperometric biosensors
    Brownson, Dale A. C.
    Banks, Craig E.
    ANALYST, 2011, 136 (10) : 2084 - 2089
  • [43] Amperometric biosensors based on platinum nanowires
    Lu, Yashuang
    Yang, Minghui
    Qu, Fengli
    Shen, Guoli
    Yu, Ruqin
    ANALYTICAL LETTERS, 2007, 40 (05) : 875 - 886
  • [44] Assembling amperometric biosensors for clinical diagnostics
    Soledad Belluzo, Maria
    Elida Ribone, Maria
    Marina Lagier, Claudia
    SENSORS, 2008, 8 (03) : 1366 - 1399
  • [45] BIOSENSORS .2. POTENTIOMETRIC AND AMPEROMETRIC
    BORMAN, S
    ANALYTICAL CHEMISTRY, 1987, 59 (18) : A1091 - +
  • [46] MODIFIED ELECTRODE SURFACE IN AMPEROMETRIC BIOSENSORS
    BARTLETT, PN
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1990, 28 (03) : B10 - B17
  • [47] Biosensors based on direct electron transfer in redox proteins
    Yunhua Wu
    Shengshui Hu
    Microchimica Acta, 2007, 159 : 1 - 17
  • [48] Biosensors based on direct electron transfer in redox proteins
    Wu, Yunhua
    Hu, Shengshui
    MICROCHIMICA ACTA, 2007, 159 (1-2) : 1 - 17
  • [49] CONDUCTING POLYMERS AND THEIR APPLICATION IN AMPEROMETRIC BIOSENSORS
    SCHUHMANN, W
    DIAGNOSTIC BIOSENSOR POLYMERS, 1994, 556 : 110 - 123
  • [50] CONDUCTING POLYMERS AND THEIR APPLICATION IN AMPEROMETRIC BIOSENSORS
    SCHUHMANN, W
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 54 - IEC