Electron transfer in amperometric biosensors

被引:0
|
作者
Polohova, Vladimira [1 ]
Snejdarkova, Maja [1 ]
机构
[1] Slovak Acad Sci, Inst Anim Biochem & Genet, Ivanka Pri Dunaji 90028, Slovakia
来源
CHEMICKE LISTY | 2008年 / 102卷 / 03期
关键词
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
At present direct electron transfer between an electrode and protein ranks among promising areas of biosensor research. This review focuses on current trends and methods in the development of third-generation amperometric biosensors. It describes the construction of the biosensors of three generations and enzyme immobilization techniques. The design of the electrode interface and biosensor architecture are essential in bioelectrocatalysis, fast electron transfer and electrode construction. Differences in the architectures usually reflect specific electron transfer mechanisms. In the second-generation biosensors, the preferred design consists of biosensors with mediators tightly bound in the active layer of the electrode surface. Attempts at the direct electron transfer employ techniques like self-assembled monolayers, conducting polymers, reconstitution of the prosthetic group and apoenzyme in active holoenzyme and integration of nanotechnology. Despite considerable efforts, no commercially available biosensors based on the direct electron transfer have been developed so far. Modem approaches such as redox proteins and enzymes with engineered electron pathways can make this type of biosensors commercially attractive.
引用
收藏
页码:173 / 182
页数:10
相关论文
共 50 条
  • [21] ELECTRON-TRANSFER PATHWAYS IN AMPEROMETRIC BIOSENSORS - FERROCENE-MODIFIED ENZYMES ENTRAPPED IN CONDUCTING-POLYMER LAYERS
    SCHUHMANN, W
    BIOSENSORS & BIOELECTRONICS, 1995, 10 (1-2): : 181 - 193
  • [22] Nonenzimatic amperometric glucose biosensors
    V. A. Buzanovskii
    Review Journal of Chemistry, 2012, 2 (2) : 153 - 170
  • [23] Amperometric biosensors in reversed micelles
    Pingarron, JM
    Reviejo, AJ
    BIOSENSORS FOR DIRECT MONITORING OF ENVIRONMENTAL POLLUTANTS IN FIELD, 1997, 38 : 305 - 316
  • [24] New technologies for amperometric biosensors
    Boutelle, MG
    Allen, H
    Hill, O
    Berners, M
    John, R
    Dobson, PD
    Leigh, P
    JOURNAL OF MOLECULAR RECOGNITION, 1996, 9 (5-6) : 664 - 671
  • [25] AMPEROMETRIC BIOSENSORS IN REVERSED MICELLES
    REVIEJO, AJ
    LIU, F
    PINGARRON, JM
    WANG, J
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1994, 374 (1-2): : 133 - 139
  • [26] SURFACE MODIFIED AMPEROMETRIC BIOSENSORS
    YACYNYCH, AM
    GEISE, RJ
    REYNOLDS, ER
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 20 - ANYL
  • [27] Implantable enzyme amperometric biosensors
    Kotanen, Christian N.
    Moussy, Francis Gabriel
    Carrara, Sandro
    Guiseppi-Elie, Anthony
    BIOSENSORS & BIOELECTRONICS, 2012, 35 (01): : 14 - 26
  • [28] Amperometric Biosensors for the Determination of Tetracycline
    R. M. Beilinson
    A. A. Yavisheva
    N. Yu. Lopatko
    E. P. Medyantseva
    Inorganic Materials, 2023, 59 : 1462 - 1469
  • [29] Amperometric Biosensors for the Determination of Tetracycline
    Beilinson, R. M.
    Yavisheva, A. A.
    Lopatko, N. Yu.
    Medyantseva, E. P.
    INORGANIC MATERIALS, 2023, 59 (14) : 1462 - 1469
  • [30] Amperometric Biosensors for Determination of Ochratoxin A
    Medyantseva, E. P.
    Thanh, H. Mai Thi
    Varlamova, R. M.
    Sakhapova, G. R.
    Tarasova, E. Yu.
    Budnikov, H. C.
    UCHENYE ZAPISKI KAZANSKOGO UNIVERSITETA-SERIYA ESTESTVENNYE NAUKI, 2012, 154 (04): : 92 - 104