A comparison of stereoscopic and monoscopic evaluation of optic disc topography using a digital optic disc stereo camera

被引:34
|
作者
Parkin, B
Shuttleworth, G
Costen, M
Davison, C
机构
[1] Southampton Gen Hosp, Southampton Eye Unit, Southampton SO16 6YD, Hants, England
[2] Bristol Eye Hosp, Bristol BS1 2LX, Avon, England
[3] Bournemouth Hosp, Bournemouth Eye Unit, Bournemouth BH7 7DW, Dorset, England
关键词
D O I
10.1136/bjo.85.11.1347
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims-To compare stereophotographic and monophotographic optic disc assessments made using a digital optic disc stereo camera. Methods-Stereo digital optic disc photographs of 150 selected patients who had presented to a glaucoma clinic were assessed by two masked observers on separate occasions using (1) the stereophotographs and a stereoviewer, (2) a single image from the same stereopair. Results were analysed for both right and left eyes separately. 95% tolerance limits for change (TC) and intraclass correlation coefficients (ICC) were calculated and a multivariate analysis using a general linear model for repeated measures was performed. Results-A total of 201 optic disc images of 150 patients (84 females, 108 left eyes) were analysed. Mean age of patients was 64 years. The results for right eyes are as follows (similar results were obtained for left eyes). Intraobserver (stereoscopic compared to monoscopic) measurements of. horizontal cup:disc ratios (CDR), ICC = 0.5995 and 0.7269, TC = 34% and 27%; vertical CDR, ICC = 0.8298 and 0.817, TC = 25% and 27%; area CDR, ICC = 0.7757 and 0.8259, TC = 28% and 25%; circumference CDR, ICC = 0.7618 and 0.8103, TC = 28% and 25%. Interobserver measurements of. horizontal CDR, ICC stereoscopic (SS) = 0.7287; monoscopic (MS) = 0.5030; TC SS = 30%; MS = 32%; vertical CDR, ICC SS = 0.8439; MS = 0.7106; TC SS = 25%; MS = 31%; area CDR, ICC SS = 0.8392; MS = 0.6276; TC SS = 26%; MS = 32%; circumference CDR, ICC SS = 0.8433; MS = 0.6438, TC SS = 26%; MS = 31%. Systematic bias between observers and between methods was within acceptable limits. Conclusions-This study using a digital stereo camera indicates that there may be little benefit of stereoscopic imaging over monoscopic imaging despite demonstrating small but inconsistent differences between both observers and methods.
引用
收藏
页码:1347 / 1351
页数:5
相关论文
共 50 条
  • [41] Differentiation between optic disc drusen and optic disc oedema using fundus photography
    Lee, Kyoung Min
    Woo, Se Joon
    Hwang, Jeong-Min
    ACTA OPHTHALMOLOGICA, 2017, 95 (04) : E329 - E335
  • [42] AUTOMATIC DETECTION OF THE OPTIC DISC USING MAJORITY VOTING IN A COLLECTION OF OPTIC DISC DETECTORS
    Balazs Harangi
    Qureshi, Rashid Jalal
    Csutak, Adrienne
    Peto, Tunde
    Andras Hajdu
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 1329 - 1332
  • [43] Assessment of stereoscopic optic disc images using an autostereoscopic screen – experimental study
    Maged S Habib
    James A Lowell
    Nick S Holliman
    Andrew Hunter
    Daniella Vaideanu
    Anthony Hildreth
    David HW Steel
    BMC Ophthalmology, 8
  • [44] Assessment of stereoscopic optic disc images using an autostereoscopic screen - experimental study
    Habib, Maged S.
    Lowell, James A.
    Holliman, Nick S.
    Hunter, Andrew
    Vaideanu, Daniella
    Hildreth, Anthony
    Steel, David H. W.
    BMC OPHTHALMOLOGY, 2008, 8 (1)
  • [45] Assessment of optic disc topography for diagnosing and monitoring glaucoma
    Weinreb, RN
    ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (09) : 1229 - 1231
  • [46] EXERCISE-INDUCED CHANGES IN OPTIC DISC TOPOGRAPHY
    ROPER, GJ
    GELVIN, J
    HARRIS, A
    MARTIN, BJ
    CANTOR, LB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1346 - 1346
  • [47] Comparison of optic disc topography before and after antiglaucoma treatment in juvenile glaucoma
    Elgin, Ufuk
    Ozturk, Faruk
    Sen, Emine
    Serdar, Kurtulus
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (05) : 907 - 910
  • [48] Optic disc puncture evaluation - In reply
    D'Amico, Donald J.
    Lit, Eugene S.
    Viola, Francesco
    ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (04) : 577 - 577
  • [49] Confounder for Optic Disc Evaluation in Glaucoma
    Thool, Archana R.
    Selukar, Kanchan V.
    Daigavane, Sachin, V
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [50] COMPUTERIZED OPTIC DISC EVALUATION (CODE)
    DAN, JA
    BELYEA, DA
    LIEBERMAN, MF
    STAMPER, RL
    TAYERI, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S970 - S970