A comparison of stereoscopic and monoscopic evaluation of optic disc topography using a digital optic disc stereo camera

被引:34
|
作者
Parkin, B
Shuttleworth, G
Costen, M
Davison, C
机构
[1] Southampton Gen Hosp, Southampton Eye Unit, Southampton SO16 6YD, Hants, England
[2] Bristol Eye Hosp, Bristol BS1 2LX, Avon, England
[3] Bournemouth Hosp, Bournemouth Eye Unit, Bournemouth BH7 7DW, Dorset, England
关键词
D O I
10.1136/bjo.85.11.1347
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims-To compare stereophotographic and monophotographic optic disc assessments made using a digital optic disc stereo camera. Methods-Stereo digital optic disc photographs of 150 selected patients who had presented to a glaucoma clinic were assessed by two masked observers on separate occasions using (1) the stereophotographs and a stereoviewer, (2) a single image from the same stereopair. Results were analysed for both right and left eyes separately. 95% tolerance limits for change (TC) and intraclass correlation coefficients (ICC) were calculated and a multivariate analysis using a general linear model for repeated measures was performed. Results-A total of 201 optic disc images of 150 patients (84 females, 108 left eyes) were analysed. Mean age of patients was 64 years. The results for right eyes are as follows (similar results were obtained for left eyes). Intraobserver (stereoscopic compared to monoscopic) measurements of. horizontal cup:disc ratios (CDR), ICC = 0.5995 and 0.7269, TC = 34% and 27%; vertical CDR, ICC = 0.8298 and 0.817, TC = 25% and 27%; area CDR, ICC = 0.7757 and 0.8259, TC = 28% and 25%; circumference CDR, ICC = 0.7618 and 0.8103, TC = 28% and 25%. Interobserver measurements of. horizontal CDR, ICC stereoscopic (SS) = 0.7287; monoscopic (MS) = 0.5030; TC SS = 30%; MS = 32%; vertical CDR, ICC SS = 0.8439; MS = 0.7106; TC SS = 25%; MS = 31%; area CDR, ICC SS = 0.8392; MS = 0.6276; TC SS = 26%; MS = 32%; circumference CDR, ICC SS = 0.8433; MS = 0.6438, TC SS = 26%; MS = 31%. Systematic bias between observers and between methods was within acceptable limits. Conclusions-This study using a digital stereo camera indicates that there may be little benefit of stereoscopic imaging over monoscopic imaging despite demonstrating small but inconsistent differences between both observers and methods.
引用
收藏
页码:1347 / 1351
页数:5
相关论文
共 50 条
  • [31] Stereo digital photography demonstrates excellent reproducibility with stereo slide film for the evaluation of glaucomatous optic disc features
    Kassam, Faazil
    Arora, Sourabh
    Rudnisky, Chris
    Douglas, Gordon
    Edwards, Marianne
    Verstraten, Karin
    Wong, Beatrice
    Damji, Karim
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [32] Comparison of vertical cup-to-disc ratio estimates using stereoscopic and monoscopic cameras
    Shrestha, Riju
    Budenz, Donald Lyle
    Mwanza, Jean-Claude
    Tulenko, Samantha Elizabeth
    Fleischman, David
    Gower, Emily West
    EYE, 2021, 35 (12) : 3318 - 3324
  • [33] Comparison of vertical cup-to-disc ratio estimates using stereoscopic and monoscopic cameras
    Riju Shrestha
    Donald Lyle Budenz
    Jean-Claude Mwanza
    Samantha Elizabeth Tulenko
    David Fleischman
    Emily West Gower
    Eye, 2021, 35 : 3318 - 3324
  • [34] CHANGES IN OPTIC DISC TOPOGRAPHY IN EXPERIMENTAL GLAUCOMA
    SHIRAKASHI, M
    IWATA, K
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1509 - 1509
  • [35] Discrimination of glaucomatous optic disc with different appearances by using optic disc morphology parameters The Glaucoma Stereo Analysis Study (GSAS)
    Tanito, Masaki
    Nitta, Koji
    Katai, Maki
    Kitaoka, Yasushi
    Yokoyama, Yu
    Omodaka, Kazuko
    Tsuda, Satoru
    Nakagawa, Toshiaki
    Nakazawa, Toru
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [36] Relationship of optic disc topography to optic nerve fiber number in glaucoma
    Yücel, YH
    Gupta, N
    Kalichman, MW
    Mizisin, AP
    Hare, W
    Lima, MD
    Zangwill, L
    Weinreb, RN
    ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (04) : 493 - 497
  • [37] Comparison of Optic Disc Topography in the Cases With Graves Disease and Healthy Controls
    Sen, Emine
    Berker, Dilek
    Elgin, Ufuk
    Tutuncu, Yasemin
    Ozturk, Faruk
    Guler, Serdar
    JOURNAL OF GLAUCOMA, 2012, 21 (09) : 586 - 589
  • [38] Comparison of Nonmydriatic Ultrawide Field Imaging and Mydriatic 30-Degree Stereo Optic Disc Photography for Optic Nerve Evaluation
    Song, Brian June
    Pasquale, Louis R.
    Cavallerano, Jerry
    Silva, Paolo Sandico
    Aiello, Lloyd P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [39] Stereo fundus photography in the diagnosis of optic disc melanocytoma
    Krohn, Jorgen
    Kjersem, Bard
    ACTA OPHTHALMOLOGICA, 2011, 89 (06) : E533 - E534
  • [40] Evaluation of optic disc measurement using indirect ophthalmoscopy
    Stuetzle, C
    Schmidt, E
    Boehm, AG
    Pillunat, LE