A comparison of stereoscopic and monoscopic evaluation of optic disc topography using a digital optic disc stereo camera

被引:34
|
作者
Parkin, B
Shuttleworth, G
Costen, M
Davison, C
机构
[1] Southampton Gen Hosp, Southampton Eye Unit, Southampton SO16 6YD, Hants, England
[2] Bristol Eye Hosp, Bristol BS1 2LX, Avon, England
[3] Bournemouth Hosp, Bournemouth Eye Unit, Bournemouth BH7 7DW, Dorset, England
关键词
D O I
10.1136/bjo.85.11.1347
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims-To compare stereophotographic and monophotographic optic disc assessments made using a digital optic disc stereo camera. Methods-Stereo digital optic disc photographs of 150 selected patients who had presented to a glaucoma clinic were assessed by two masked observers on separate occasions using (1) the stereophotographs and a stereoviewer, (2) a single image from the same stereopair. Results were analysed for both right and left eyes separately. 95% tolerance limits for change (TC) and intraclass correlation coefficients (ICC) were calculated and a multivariate analysis using a general linear model for repeated measures was performed. Results-A total of 201 optic disc images of 150 patients (84 females, 108 left eyes) were analysed. Mean age of patients was 64 years. The results for right eyes are as follows (similar results were obtained for left eyes). Intraobserver (stereoscopic compared to monoscopic) measurements of. horizontal cup:disc ratios (CDR), ICC = 0.5995 and 0.7269, TC = 34% and 27%; vertical CDR, ICC = 0.8298 and 0.817, TC = 25% and 27%; area CDR, ICC = 0.7757 and 0.8259, TC = 28% and 25%; circumference CDR, ICC = 0.7618 and 0.8103, TC = 28% and 25%. Interobserver measurements of. horizontal CDR, ICC stereoscopic (SS) = 0.7287; monoscopic (MS) = 0.5030; TC SS = 30%; MS = 32%; vertical CDR, ICC SS = 0.8439; MS = 0.7106; TC SS = 25%; MS = 31%; area CDR, ICC SS = 0.8392; MS = 0.6276; TC SS = 26%; MS = 32%; circumference CDR, ICC SS = 0.8433; MS = 0.6438, TC SS = 26%; MS = 31%. Systematic bias between observers and between methods was within acceptable limits. Conclusions-This study using a digital stereo camera indicates that there may be little benefit of stereoscopic imaging over monoscopic imaging despite demonstrating small but inconsistent differences between both observers and methods.
引用
收藏
页码:1347 / 1351
页数:5
相关论文
共 50 条
  • [1] A new digital optic disc stereo camera: intraobserver and interobserver repeatability of optic disc measurements
    Shuttleworth, GN
    Khong, CH
    Diamond, JP
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (04) : 403 - 407
  • [2] Utility of Digital Stereo Images for Optic Disc Evaluation
    Stone, Richard A.
    Ying, Gui-shuang
    Pearson, Denise J.
    Bansal, Mayank
    Puri, Manika
    Miller, Eydie
    Alexander, Judith
    Piltz-Seymour, Jody
    Nyberg, William
    Maguire, Maureen G.
    Eledath, Jayan
    Sawhney, Harpreet
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (11) : 5667 - 5674
  • [3] Digital stereoscopic analysis of the optic disc - Evaluation of a teaching program
    Sheen, NJL
    Morgan, JE
    Poulsen, JL
    North, RV
    OPHTHALMOLOGY, 2004, 111 (10) : 1873 - 1879
  • [4] Reproducibility of evaluation of optic disc change for glaucoma with stereo optic disc photographs
    Miglior, S
    Zeyen, T
    Pfeiffer, N
    Cunha-Vaz, J
    Linsen, MC
    Pellicci, L
    Janssens, A
    van der Veken, A
    Nerinckx, F
    Boeyden, V
    Czupper, M
    Wendrix, G
    Detry-Morel, M
    Kestelyn, P
    Van den Abeele, K
    Jacobs, K
    Decock, C
    Goethals, M
    Pourjavan, S
    Maris, K
    Deghislage, C
    Kersten, I
    Vogel, A
    Herkel, U
    Schwenn, O
    Maser-Wahle, M
    Funk, J
    Schmidt, B
    Akbariyeh, N
    Burk, R
    Thomsen, A
    Grehn, F
    Marquardt, D
    Orzalesi, N
    Rossetti, L
    Ferrante, M
    Mandelli, L
    Marini, S
    Bertoni, G
    Blini, M
    De Molfetta, M
    Bonomi, L
    Morbio, R
    Marraffa, M
    Maraini, G
    Gandolfi, S
    Williams, S
    Cimino, L
    Dondi, P
    Lumbroso, B
    OPHTHALMOLOGY, 2003, 110 (02) : 340 - 344
  • [5] Digital stereoscopic analysis of the optic disc.
    Morgan, JE
    Sheen, N
    Choong, Y
    Ansari, E
    North, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S289 - S289
  • [6] Evaluation of digital stereoscopic optic disc images using a Z screen.
    Sheen, NJL
    Goyal, R
    Wild, J
    North, RV
    Morgan, JE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S19 - S19
  • [7] Agreement in assessing optic discs with a digital stereoscopic optic disc camera (Discam) and Heidelberg retina tomograph
    Sung, VCT
    Bhan, A
    Vernon, SA
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (02) : 196 - 202
  • [8] Digital stereoscopic optic disc assessment: evaluation of a teaching module.
    Morgan, JE
    Poulsen, JL
    North, RV
    Sheen, NJL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S133 - S133
  • [9] Assessment of digital stereoscopic optic disc images using a Z screen
    Morgan, JE
    Sheen, NJL
    Goyal, R
    Wild, JM
    North, RV
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U223 - U223
  • [10] Assessment of digital stereoscopic optic disc images using a Z Screen
    Morgan, JE
    Sheen, NJ
    Goyal, R
    Wild, JM
    North, RV
    PERIMETRY UPDATE 2002/2003, 2004, : 309 - 316