Adaptation of continuous-flow cavity ring-down spectroscopy for batch analysis of δ13C of CO2 and comparison with isotope ratio mass spectrometry

被引:22
|
作者
Berryman, E. M. [1 ]
Marshall, J. D. [1 ]
Rahn, T. [3 ]
Cook, S. P. [2 ]
Litvak, M. [4 ]
机构
[1] Univ Idaho, Dept Forest Ecol & Biogeosci, Moscow, ID 83843 USA
[2] Univ Idaho, Dept Plant Soil & Entomol Sci, Moscow, ID 83843 USA
[3] Los Alamos Natl Lab, Div Earth & Environm Sci, Los Alamos, NM 87545 USA
[4] Univ New Mexico, Dept Biol, Albuquerque, NM 87131 USA
关键词
KEELING PLOT APPLICATIONS; TUNABLE DIODE-LASER; SOIL-RESPIRED CO2; ECOSYSTEM RESPIRATION; FOREST SOIL; CARBON; ATMOSPHERE; EFFLUX; SYSTEM;
D O I
10.1002/rcm.5108
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Measurements of delta C-13 in CO2 have traditionally relied on samples stored in sealed vessels and subsequently analyzed using magnetic sector isotope ratio mass spectrometry (IRMS), an accurate but expensive and high-maintenance analytical method. Recent developments in optical spectroscopy have yielded instruments that can measure delta(CO2)-C-13 in continuous streams of air with precision and accuracy approaching those of IRMS, but at a fraction of the cost. However, continuous sampling is unsuited for certain applications, creating a need for conversion of these instruments for batch operation. Here, we present a flask (syringe) adaptor that allows the collection and storage of small aliquots (20-30mL air) for injection into the cavity ring-down spectroscopy (CRDS) instrument. We demonstrate that the adaptor's precision is similar to that of traditional IRMS (standard deviation of 0.3 parts per thousand for 385ppm CO2 standard gas). In addition, the concentration precision (+/- 0.3% of sample concentration) was higher for CRDS than for IRMS (+/- 7% of sample concentration). Using the adaptor in conjunction with CRDS, we sampled soil chambers and found that soil-respired delta C-13 varied between two different locations in a pinon-juniper woodland. In a second experiment, we found no significant discrimination between the respiration of a small beetle (similar to 5mm) and its diet. Our work shows that the CRDS system is flexible enough to be used for the analysis of batch samples as well as for continuous sampling. This flexibility broadens the range of applications for which CRDS has the potential to replace magnetic sector IRMS. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:2355 / 2360
页数:6
相关论文
共 50 条
  • [1] Comparison of water isotope analysis between cavity ring-down spectroscopy and isotope ratio mass spectrometry
    Maruyama, Seiji
    Tada, Yohei
    GEOCHEMICAL JOURNAL, 2014, 48 (01) : 105 - 109
  • [2] A comparison of isotope ratio mass spectrometry and cavity ring-down spectroscopy techniques for isotope analysis of fluid inclusion water
    de Graaf, Stefan
    Vonhof, Hubert B.
    Weissbach, Therese
    Wassenburg, Jasper A.
    Levy, Elan J.
    Kluge, Tobias
    Haug, Gerald H.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (16)
  • [3] Field-based cavity ring-down spectrometry of 13C in soil-respired CO2
    Munksgaard, Niels C.
    Davies, Kalu
    Wurster, Chris M.
    Bass, Adrian M.
    Bird, Michael I.
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2013, 49 (02) : 232 - 242
  • [4] Applications of cavity ring-down spectroscopy to high precision isotope ratio measurement of 13C/12C in carbon dioxide
    Wahl, EH
    Fidric, B
    Rella, CW
    Koulikov, S
    Kharlamov, B
    Tan, S
    Kachanov, AA
    Richman, BA
    Crosson, ER
    Paldus, BA
    Kalaskar, S
    Bowling, DR
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2006, 42 (01) : 21 - 35
  • [5] Measurements of 13C/12C Methane from Anaerobic Digesters: Comparison of Optical Spectrometry with Continuous-Flow Isotope Ratio Mass Spectrometry
    Keppler, Frank
    Laukenmann, Stephan
    Rinne, Jennifer
    Heuwinkel, Hauke
    Greule, Markus
    Whiticar, Michael
    Lelieveld, Jos
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (13) : 5067 - 5073
  • [6] Comparison between isotope ratio mass spectrometry (IRMS) and cavity ring-down spectroscopy (CRDS) for analysing the carbon isotope ratio and detection of adulteration in coconut water
    Meepho, Sang-Arun
    Kamdee, Kiattipong
    Saengkorakot, Chakrit
    Thapprathum, Phornthip
    Judprasong, Kunchit
    INTERNATIONAL JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 2021, 56 (12): : 6611 - 6617
  • [7] Rapid 18O analysis of CO2 samples by continuous-flow isotope ratio mass spectrometry
    Schoeller, DA
    Luke, AH
    JOURNAL OF MASS SPECTROMETRY, 1997, 32 (12): : 1332 - 1336
  • [8] A sealed-tube method for offline δ13C analysis of CO2 via a Gas Bench II continuous-flow isotope ratio mass spectrometer
    Walker, Brett D.
    Beaupre, Steven R.
    Griffin, Sheila
    Walker, Jennifer
    Druffel, Ellen
    Xu, Xiaomei
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (07)
  • [9] Comparison of isotope ratio mass spectrometry and cavity ring-down spectroscopy procedures and precision of the doubly labeled water method in different physiological specimens
    Sagayama, Hiroyuki
    Racine, Natalie M.
    Shriver, Timothy C.
    Schoeller, Dale A.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (21)
  • [10] Comparison of water isotope-ratio determinations using two cavity ring-down instruments and classical mass spectrometry in continuous ice-core analysis
    Maselli, Olivia J.
    Fritzsche, Diedrich
    Layman, Lawrence
    McConnell, Joseph R.
    Meyer, Hanno
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2013, 49 (03) : 387 - 398