Applications of cavity ring-down spectroscopy to high precision isotope ratio measurement of 13C/12C in carbon dioxide

被引:65
|
作者
Wahl, EH
Fidric, B
Rella, CW
Koulikov, S
Kharlamov, B
Tan, S
Kachanov, AA
Richman, BA
Crosson, ER
Paldus, BA
Kalaskar, S
Bowling, DR
机构
[1] Picarro Inc, Sunnyvale, CA 94085 USA
[2] Univ Utah, Dept Biol, Salt Lake City, UT 84112 USA
关键词
atmosphere; carbon dioxide; carbon-12; carbon-13; cavity ring-down spectroscopy; infrared diode laser;
D O I
10.1080/10256010500502934
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Recent measurements of carbon isotopes in carbon dioxide using near-infrared, diode-laser-based cavity ring-down spectroscopy (CRDS) are presented. The CRDS system achieved good precision, often better than 0.2%, for 4% CO2 concentrations, and also achieved 0.15-0.25% precision in a 78 min measurement time with cryotrap-based pre-concentration of ambient CO2 concentrations (360 ppmv). These results were obtained with a CRDS system possessing a data rate of 40 ring-downs per second and a loss measurement of 4.0 x 10(-11) cm(-1) Hz(-1/2) . Subsequently, the measurement time has been reduced to under 10 min. This standard of performance would enable a variety of high concentration (3-10%) isotopic measurements, such as medical human breath analysis or animal breath experiments. The extension of this ring-down to the 2 mu m region would enable isotopic analysis at ambient concentrations, which, combined with the small size, robust design, and potential for frequent measurements at a remote site, make CRDS technology attractive for remote atmospheric measurement applications.
引用
收藏
页码:21 / 35
页数:15
相关论文
共 50 条
  • [1] Stable isotope ratios using cavity ring-down spectroscopy:: Determination of 13C/12C for carbon dioxide in human breath
    Crosson, ER
    Ricci, KN
    Richman, BA
    Chilese, FC
    Owano, TG
    Provencal, RA
    Todd, MW
    Glasser, J
    Kachanov, AA
    Paldus, BA
    Spence, TG
    Zare, RN
    ANALYTICAL CHEMISTRY, 2002, 74 (09) : 2003 - 2007
  • [2] Rapid Scanning Cavity Ring-down Spectrometer for the Precision Measurement of 13C/12C for CO2 in Air
    Yi, Hongming
    Srivastava, Abneesh
    Fleisher, Adam J.
    Hodges, Joseph T.
    2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,
  • [3] Line strength measurements and relative isotopic ratio 13C/12C measurements in carbon dioxide using cavity ring down spectroscopy
    Kiseleva, M.
    Mandon, J.
    Persijn, S.
    Harren, F. J. M.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2018, 204 : 152 - 158
  • [4] Determination of 13C/12C carbon isotope ratio
    Zanasi, Riccardo
    Alfano, Davide
    Scarabino, Carla
    Motta, Oriana
    Viglione, Rosario G.
    Proto, Antonio
    ANALYTICAL CHEMISTRY, 2006, 78 (09) : 3080 - 3083
  • [5] Measurement of the 13C/12C of Atmospheric CH4 Using Near-Infrared (NIR) Cavity Ring-Down Spectroscopy
    Chen, Y.
    Lehmann, Kevin. K.
    Kessler, J.
    Lollar, B. Sherwood
    Couloume, G. Lacrampe
    Onstottt, T. C.
    ANALYTICAL CHEMISTRY, 2013, 85 (23) : 11250 - 11257
  • [6] Determination of the 13C/12C Carbon Isotope Ratio in Carbonates and Bicarbonates by 13C NMR Spectroscopy
    Pironti, Concetta
    Cucciniello, Raffaele
    Camin, Federica
    Tonon, Agostino
    Motta, Oriana
    Proto, Antonio
    ANALYTICAL CHEMISTRY, 2017, 89 (21) : 11413 - 11418
  • [7] Carbon 12C/13C isotope ratio of α Aurigae revised
    Sablowski, Daniel P.
    Jaervinen, Silva
    Ilyin, Ilya
    Strassmeier, Klaus G.
    ASTRONOMY & ASTROPHYSICS, 2019, 622
  • [8] Carbon isotope ratio (13C/12C) of pine honey and detection of HFCS adulteration
    Cinar, Serap B.
    Eksi, Aziz
    Coskun, Ilknur
    FOOD CHEMISTRY, 2014, 157 : 10 - 13
  • [9] The 13C/12C isotopic ratio determined by FTIR spectroscopy
    Soderholm, S
    Meinander, N
    Kauppinen, J
    FOURIER TRANSFORM SPECTROSCOPY, 1998, (430): : 223 - 226
  • [10] Carbon isotope effects (13C/12C) in biological systems