Adaptation of continuous-flow cavity ring-down spectroscopy for batch analysis of δ13C of CO2 and comparison with isotope ratio mass spectrometry

被引:22
|
作者
Berryman, E. M. [1 ]
Marshall, J. D. [1 ]
Rahn, T. [3 ]
Cook, S. P. [2 ]
Litvak, M. [4 ]
机构
[1] Univ Idaho, Dept Forest Ecol & Biogeosci, Moscow, ID 83843 USA
[2] Univ Idaho, Dept Plant Soil & Entomol Sci, Moscow, ID 83843 USA
[3] Los Alamos Natl Lab, Div Earth & Environm Sci, Los Alamos, NM 87545 USA
[4] Univ New Mexico, Dept Biol, Albuquerque, NM 87131 USA
关键词
KEELING PLOT APPLICATIONS; TUNABLE DIODE-LASER; SOIL-RESPIRED CO2; ECOSYSTEM RESPIRATION; FOREST SOIL; CARBON; ATMOSPHERE; EFFLUX; SYSTEM;
D O I
10.1002/rcm.5108
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Measurements of delta C-13 in CO2 have traditionally relied on samples stored in sealed vessels and subsequently analyzed using magnetic sector isotope ratio mass spectrometry (IRMS), an accurate but expensive and high-maintenance analytical method. Recent developments in optical spectroscopy have yielded instruments that can measure delta(CO2)-C-13 in continuous streams of air with precision and accuracy approaching those of IRMS, but at a fraction of the cost. However, continuous sampling is unsuited for certain applications, creating a need for conversion of these instruments for batch operation. Here, we present a flask (syringe) adaptor that allows the collection and storage of small aliquots (20-30mL air) for injection into the cavity ring-down spectroscopy (CRDS) instrument. We demonstrate that the adaptor's precision is similar to that of traditional IRMS (standard deviation of 0.3 parts per thousand for 385ppm CO2 standard gas). In addition, the concentration precision (+/- 0.3% of sample concentration) was higher for CRDS than for IRMS (+/- 7% of sample concentration). Using the adaptor in conjunction with CRDS, we sampled soil chambers and found that soil-respired delta C-13 varied between two different locations in a pinon-juniper woodland. In a second experiment, we found no significant discrimination between the respiration of a small beetle (similar to 5mm) and its diet. Our work shows that the CRDS system is flexible enough to be used for the analysis of batch samples as well as for continuous sampling. This flexibility broadens the range of applications for which CRDS has the potential to replace magnetic sector IRMS. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:2355 / 2360
页数:6
相关论文
共 50 条
  • [21] Oxygen isotope measurements of seawater (H218O/H216O): A comparison of cavity ring-down spectroscopy (CRDS) and isotope ratio mass spectrometry (IRMS)
    Walker, S. A.
    Azetsu-Scott, K.
    Normandeau, C.
    Kelley, D. E.
    Friedrich, R.
    Newton, R.
    Schlosser, P.
    McKay, J. L.
    Abdi, W.
    Kerrigan, E.
    Craig, S. E.
    Wallace, D. W. R.
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2016, 14 (01): : 31 - 38
  • [22] Cavity ring-down spectroscopy of CO2 overtone bands near 830 nm
    Tan, Y.
    Zhao, X. -Q.
    Liu, A-W
    Hu, S. -M.
    Lyulin, O. M.
    Tashkun, S. A.
    Perevalov, V. I.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2015, 165 : 22 - 27
  • [23] A new method for determining δ13C and δD simultaneously for CH4 by gas chromatography continuous-flow isotope-ratio mass spectrometry
    Potter, J
    Siemann, MG
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (02) : 175 - 180
  • [24] Stable chlorine isotope ratio analysis of subnanomolar level methyl chloride by continuous-flow isotope ratio mass spectrometry
    Konno, Uta
    Takai, Ken
    Kawagucci, Shinsuke
    GEOCHEMICAL JOURNAL, 2013, 47 (04) : 469 - 473
  • [25] Analysis of the 13C natural abundance of CO2 gas from sparkling drinks by gas chromatography/combustion/isotope ratio mass spectrometry
    Calderone, G
    Naulet, N
    Guillou, C
    Reniero, F
    Cortes, AIB
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (05) : 701 - 705
  • [26] Direct Comparison of Cavity Ring Down Spectrometry and Isotope Ratio Mass Spectrometry for Detection of Sugar Adulteration in Honey Samples
    Mantha, Madhavi
    Urban, John R.
    Mark, William A.
    Chernyshev, Anatoly
    Kubachka, Kevin M.
    JOURNAL OF AOAC INTERNATIONAL, 2018, 101 (06) : 1857 - 1863
  • [27] Automation of 14C-labeled, biological-sample measurements by cavity ring-down spectroscopy and comparison to accelerator mass spectrometry
    McCartt, Alan
    Ognibene, Ted
    Bench, Graham
    Turteltaub, Kenneth
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [28] Analysis of quantization error in high-precision continuous-flow isotope ratio mass spectrometry
    Sacks, GL
    Wolyniak, CJ
    Brenna, JT
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1020 (02) : 273 - 282
  • [29] Optimization of automated gas sample collection and isotope ratio mass spectrometric analysis of δ13C Of CO2 in air
    Zeeman, Matthias J.
    Werner, Roland A.
    Eugster, Werner
    Siegwolf, Rolf T. W.
    Wehrle, Guenther
    Mohn, Joachim
    Buchmann, Nina
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (23) : 3883 - 3892
  • [30] Laser analysis of the 13C/12C isotope ratio in CO2 in exhaled air
    Stepanov, EV
    QUANTUM ELECTRONICS, 2002, 32 (11) : 981 - 986