This paper presents a comparison of three different techniques used for the generation of the current reference signal in shunt active power filters. The three different techniques are evaluated and compared in terms of compensation performance under steady state and transient operating conditions, implementations requirements, and compensation in four wire power distribution systems, with unbalanced single phase nonlinear loads. The three techniques analyzed are the Instantaneous Reactive Power Theory (PQ Theory), the Synchronous Reference Frame Theory (SRF) and Peak Detection Method (PDM). The technical evaluation is done by considering the robustness for the operation with unbalanced and distorted supply voltages, unbalanced load currents, control signals conditioning and processing delays introduced by the implementation with a DSP. The comparison is based on theoretical analysis and simulated results obtained with Matlab. The principal conclusion is that the compensation performance of the different techniques is similar under ideal conditions, but under the presence of unbalanced and voltage distortion, the compensation performance is quite different, and not all the reference methods allows full compensation. The Synchronous Reference Frame algorithm presents the best performance for different operating conditions.
引用
收藏
页码:791 / 796
页数:6
相关论文
共 50 条
  • [41] Research on Three-Phase Four-wire Shunt Active Power Filter for Harmonic and Reactive Compensation
    TianYue-xin
    Cao Hai-yan
    Zhu Yan-ping
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 4174 - +
  • [42] Control of a shunt active power filter based on a three-leg four-wire electronic converter
    Garcia-Gonzalez, P.
    Garcia-Cerrada, A.
    Pinzon-Ardila, O.
    CPE: 2009 COMPATIBILITY AND POWER ELECTRONICS, 2009, : 292 - 297
  • [43] Three-phase four-wire shunt active power filter working simultaneously as energy conditioner
    Szromba, Andrzej
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2017, 36 (03) : 702 - 715
  • [44] High Precision Control Strategy for Three-Phase Four-Wire Shunt Active Power Filter
    Xu, Qunwei
    Zhong, Xiaojian
    Yao, Wenxi
    Chen, Guozhu
    2014 IEEE 23RD INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2014, : 509 - 514
  • [45] Analysis of DC-Link Voltage Controls in Three-Phase Four-Wire Hybrid Active Power Filters
    Choi, Wai-Hei
    Lam, Chi-Seng
    Wong, Man-Chung
    Han, Ying-Duo
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (05) : 2180 - 2191
  • [46] Comparative Study of Reference Current Generation for Shunt Active Power Filter
    Panchbhai, Anand
    Prajapati, Nikunj
    Parmar, Shreya
    2017 INTERNATIONAL CONFERENCE ON POWER AND EMBEDDED DRIVE CONTROL (ICPEDC), 2017, : 381 - 386
  • [47] Minimization of Cable Losses in Three-Phase Four-Wire Systems by means of Instantaneous Compensation with Shunt Active Filters
    Artemenko, M. Yu.
    Batrak, L. M.
    Polishchuk, S. Y.
    Mykhalskyi, V. M.
    Shapoval, I. A.
    2013 IEEE XXXIII INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2013, : 359 - 362
  • [48] Parallel operation of capacity-limited three-phase four-wire active power filters
    Chiang, SJ
    Ai, WJ
    Lin, FJ
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2002, 149 (05): : 329 - 336
  • [49] The Effect of Load Power Factor on the Efficiency of Three-Phase Four-Wire Power System with Shunt Active Filter
    Artemenko, M. Yu.
    Batrak, L. M.
    Polishchuk, S. Y.
    Mykhalskyi, V. M.
    Shapoval, I. A.
    2016 IEEE 36TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2016, : 277 - 282
  • [50] Shunt active filter with three-phase four-wire NPC inverter
    Lin, BR
    Chiang, HK
    Yang, KT
    2004 47TH MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL II, CONFERENCE PROCEEDINGS, 2004, : 281 - 284