3D ultrasound navigation system for screw insertion in posterior spine surgery: a phantom study

被引:6
|
作者
Chan, Andrew [1 ]
Parent, Eric [2 ]
Mahood, Jim [3 ]
Lou, Edmond [1 ,3 ,4 ]
机构
[1] Univ Alberta, Dept Biomed Engn, 1098 Res Transit Facil, 8308-114 St, Edmonton, AB T6G 2V2, Canada
[2] Univ Alberta, Fac Rehabil Med, Dept Phys Therapy, 2-50 Corbett Hall, Edmonton, AB T6G 2G4, Canada
[3] Univ Alberta, 2D Walter C Mackenzie Hlth Sci Ctr, Dept Surg, 8440-112 St, Edmonton, AB T6G 2B7, Canada
[4] Univ Alberta, Dept Elect Engn, Donadeo ICE 11 263, 9211-116 St, Edmonton, AB T6G 1H9, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
3D ultrasound (3DUS); Image guidance; Motion tracking; Scoliosis; Image registration; ADOLESCENT IDIOPATHIC SCOLIOSIS; ACCURACY; REGISTRATION; CT; PLACEMENT; VERTEBRAE; FUSION;
D O I
10.1007/s11548-021-02516-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Posterior spinal fusion surgery is required to correct severe idiopathic scoliosis. The surgery involves insertion of screws which requires high accuracy to prevent neurologic damage to the spinal cord. Although conventional CT navigation can reduce this risk, 3D-ultrasound-based navigation could achieve this without added ionizing radiation and usage of expensive and bulky equipment. This study aimed to evaluate the accuracy of a 3D ultrasound navigation system for posterior spine surgery. Methods A custom 3D ultrasound (3DUS) with model-to-surface registration algorithm was developed and integrated into a 3D navigation environment. A CT scan of an adolescent spine (T3-T11) was segmented and 3D printed for experiments. A probe with reflective markers was placed in vertebral pedicles 684 times in varying levels, positions in the capture space and orientation of vertebra, and the entrypoint and trajectory accuracies were measured. Results Among 684 probe placements in vertebral levels T3 to T11 in the phantom spine, 95.5% were within 1 mm and 5 degrees of accuracy, with an average accuracy of 0.4 +/- 0.4 mm and 2.1 +/- 0.9 degrees, requiring 8.8 s to process. Accuracies were statistically significantly affected by vertebral orientation and position in the capture volume, though this was still within the targeted accuracies of 1 mm and 5 degrees. Conclusion This preliminary ultrasound-based navigation system is accurate and fast enough for guiding placement of pedicle screws into the spine in posterior fusion surgery. The current results are limited to phantom spines, and future study in animal or human cadavers is needed to investigate soft tissue effects on registration accuracy.
引用
收藏
页码:271 / 281
页数:11
相关论文
共 50 条
  • [41] A framework for human spine imaging using a freehand 3D ultrasound system
    Purnama, Ketut E.
    Wilkinson, Michael. H. F.
    Veldhuizen, Albert G.
    van Ooijen, Peter. M. A.
    Lubbers, Jaap
    Burgerhof, Johannes G. M.
    Sardjono, Tri A.
    Verkerke, Gijbertus J.
    TECHNOLOGY AND HEALTH CARE, 2010, 18 (01) : 1 - 17
  • [42] Accuracy of Patient-Specific 3D-Printed Guides for Pedicle Screw Insertion in Spine Revision Surgery: Results of a Retrospective Study
    Faldini, Cesare
    Barile, Francesca
    Cerasoli, Tosca
    Ialuna, Marco
    Viroli, Giovanni
    Manzetti, Marco
    Traversari, Matteo
    Mazzotti, Antonio
    Ruffilli, Alberto
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2022, 41
  • [43] Navigation in Orthognathic Surgery: 3D Accuracy
    Badiali, Giovanni
    Roncari, Andrea
    Bianchi, Alberto
    Taddei, Fulvia
    Marchetti, Claudio
    Schileo, Enrico
    FACIAL PLASTIC SURGERY, 2015, 31 (05) : 463 - 473
  • [44] 3D navigation in surgery of Eagle syndrome
    Czako, L.
    Hirjak, D.
    Simko, K.
    Thurzo, A.
    Janovszky, A.
    Galis, B.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2019, 120 (07): : 494 - 497
  • [45] 3D TENDON STRAIN ESTIMATION ON HIGH-FREQUENCY 3D ULTRASOUND IMAGES A SIMULATION AND PHANTOM STUDY
    Carvalho, C.
    Bogaerts, S.
    Scheys, L.
    D'hooge, J.
    Peers, K.
    Suetens, P.
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 172 - 175
  • [46] Evaluation of 2D and 3D navigation for iliosacral screw fixation
    Daniel Behrendt
    Maria Mütze
    Hanno Steinke
    Martin Koestler
    Christoph Josten
    Jörg Böhme
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 249 - 255
  • [47] 3D Ultrasound Parametric Modeling Imaging for Spine Deformity - A Preliminary Study
    Gao, Yuchong
    Zeng, Hongye
    Zhao, Jianhao
    Zhang, Mingbo
    Zheng, Rui
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [48] Evaluation of 2D and 3D navigation for iliosacral screw fixation
    Behrendt, Daniel
    Muetze, Maria
    Steinke, Hanno
    Koestler, Martin
    Josten, Christoph
    Boehme, Jorg
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (02) : 249 - 255
  • [49] Iliosacral screw insertion using CT-3D-fluoroscopy matching navigation
    Takao, Masaki
    Nishii, Takashi
    Sakai, Takashi
    Yoshikawa, Hideki
    Sugano, Nobuhiko
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (06): : 988 - 994
  • [50] Validation of spine SBRT using a 3D printed Anthropomorphic phantom
    Dekker, K. H.
    Alexander, K. M.
    de Moraes, F. Ynoe
    Olding, T.
    11TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, IC3DDOSE, 2022, 2167