Application of a shape-memory alloy internal fixator for treatment of acetabular fractures with a follow-up of two to nine years in China

被引:44
|
作者
Liu, Xinwei [1 ]
Xu, Shuogui [1 ]
Zhang, Chuncai [1 ]
Su, Jiacan [1 ]
Yu, Baoqing [1 ]
机构
[1] Second Mil Med Univ, Changhai Hosp, Dept Orthopaed Surg, Shanghai 200433, Peoples R China
关键词
POSTERIOR WALL FRACTURES; NICKEL-TITANIUM; BONE; REDUCTION;
D O I
10.1007/s00264-009-0867-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Displaced acetabular fractures should be treated surgically. Over the past decade, surgical approaches to the acetabulum and the surgical technique for repair of common fracture patterns have advanced. Excellent outcomes after repair of these injuries can be achieved. The aim of this study was to assess the medium-term results of reconstruction of acetabular fractures by using shape-memory alloy designed by the authors. This is a retrospective review conducted at a level 1 trauma centre. From October 1999 to July 2009, 19 patients with acetabular fractures were treated with our patented Ni-Ti shape-memory alloy acetabular tridimensional memory alloy-fixation system (ATMFS). The ATMFS device was cooled with ice before implantation and then warmed to 40-50A degrees C after implantation to produce balanced axial and compression forces that would stabilise the fracture three dimensionally. Our results are as follows; according to the D'Aubigne-Postel scoring system: Fifteen cases out of 19 (79%) achieved excellent or good clinical results. In two patients, late complications included avascular necrosis of the femoral head (ANFH) associated with posterior dislocation of the hip joint two years after the operation. We also observed two cases of grade II or III ectopic ossification, with good hip function, and one case of traumatic arthritis. In conclusion, these results demonstrate the effectiveness of the ATMFS device for the management of acetabular fracture. The device provides continuous compression of the fracture with minimal disruption to the local blood supply.
引用
收藏
页码:1033 / 1040
页数:8
相关论文
共 50 条
  • [41] Total Hip Arthroplasty Using Modular Trabecular Metal Acetabular Components for Failed Treatment of Acetabular Fractures: A Mid-term Follow-up Study
    Huang De-Yong
    Zhang Liang
    Zhou Yi-Xin
    Zhang Chun-Yu
    Xu Hui
    Huang Yong
    中华医学杂志英文版, 2016, 129 (08) : 903 - 908
  • [42] Total Hip Arthroplasty Using Modular Trabecular Metal Acetabular Components for Failed Treatment of Acetabular Fractures: A Mid-term Follow-up Study
    Huang, De-Yong
    Zhang, Liang
    Zhou, Yi-Xin
    Zhang, Chun-Yu
    Xu, Hui
    Huang, Yong
    CHINESE MEDICAL JOURNAL, 2016, 129 (08) : 903 - 908
  • [43] Outcomes, risk factors, and conversion rate in acetabular fractures in patients over 65 years of age. Analysis at a mean follow-up of 6 years
    Llano, Lionel
    Ignacio Theaux, Juan
    Taype, Danilo
    Sancineto, Carlos
    Carabelli, Guido
    Barla, Jorge
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54
  • [44] Incidence of adjacent vertebral fractures in patients treated with balloon kyphoplasty: Two years' prospective follow-up
    Pflugmacher, R.
    Schroeder, R. -J.
    Klostermann, C. K.
    ACTA RADIOLOGICA, 2006, 47 (08) : 830 - 840
  • [45] Predictors for post-traumatic hip osteoarthritis in patients with transverse acetabular fractures following open reduction internal fixation: a minimum of 2 years' follow-up multicenter study
    Li, Junran
    Jin, Lin
    Chen, Chuanjie
    Zhai, Jingxiu
    Li, Ligeng
    Hou, Zhiyong
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [46] Predictors for post-traumatic hip osteoarthritis in patients with transverse acetabular fractures following open reduction internal fixation: a minimum of 2 years’ follow-up multicenter study
    Junran Li
    Lin Jin
    Chuanjie Chen
    Jingxiu Zhai
    Ligeng Li
    Zhiyong Hou
    BMC Musculoskeletal Disorders, 24
  • [47] Nine years follow-up after interferon (IFN) treatment for chronic hepatitis B (CHB) in Chinese patients
    Lau, GKK
    Lim, W
    Lok, ASF
    HEPATOLOGY, 1997, 26 (04) : 523 - 523
  • [48] Bioabsorbable Coronary Artery Stents: Patient Follow-up After Two Years Of Treatment
    Sirtautas, Azuolas
    Pranevicius, Robertas
    Briedis, Kasparas
    Zapustas, Norvydas
    Unikas, Ramunas
    Valuckiene, Zivile
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (03) : S8 - S8
  • [49] Acute treatment of elderly patients with acetabular fractures by open reduction, internal fixation, and total hip arthroplasty: a 1-10-year follow-up of 48 patients
    Kirkeboe, Ragnhild Loven
    Madsen, Jan Erik
    Nordsletten, Lars
    Clarke-Jenssen, John
    ACTA ORTHOPAEDICA, 2024, 95 : 661 - 666
  • [50] Is Ankle Arthrodesis With an Ilizarov External Fixator an Effective Treatment for Septic Ankle Arthritis? A Study With a Minimum of 6 Years of Follow-up
    Wang, Shanxi
    Li, Bohua
    Yu, Xiaojun
    Wu, Hua
    Liu, Lei
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2023, 481 (04) : 717 - 725