Application of a shape-memory alloy internal fixator for treatment of acetabular fractures with a follow-up of two to nine years in China

被引:44
|
作者
Liu, Xinwei [1 ]
Xu, Shuogui [1 ]
Zhang, Chuncai [1 ]
Su, Jiacan [1 ]
Yu, Baoqing [1 ]
机构
[1] Second Mil Med Univ, Changhai Hosp, Dept Orthopaed Surg, Shanghai 200433, Peoples R China
关键词
POSTERIOR WALL FRACTURES; NICKEL-TITANIUM; BONE; REDUCTION;
D O I
10.1007/s00264-009-0867-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Displaced acetabular fractures should be treated surgically. Over the past decade, surgical approaches to the acetabulum and the surgical technique for repair of common fracture patterns have advanced. Excellent outcomes after repair of these injuries can be achieved. The aim of this study was to assess the medium-term results of reconstruction of acetabular fractures by using shape-memory alloy designed by the authors. This is a retrospective review conducted at a level 1 trauma centre. From October 1999 to July 2009, 19 patients with acetabular fractures were treated with our patented Ni-Ti shape-memory alloy acetabular tridimensional memory alloy-fixation system (ATMFS). The ATMFS device was cooled with ice before implantation and then warmed to 40-50A degrees C after implantation to produce balanced axial and compression forces that would stabilise the fracture three dimensionally. Our results are as follows; according to the D'Aubigne-Postel scoring system: Fifteen cases out of 19 (79%) achieved excellent or good clinical results. In two patients, late complications included avascular necrosis of the femoral head (ANFH) associated with posterior dislocation of the hip joint two years after the operation. We also observed two cases of grade II or III ectopic ossification, with good hip function, and one case of traumatic arthritis. In conclusion, these results demonstrate the effectiveness of the ATMFS device for the management of acetabular fracture. The device provides continuous compression of the fracture with minimal disruption to the local blood supply.
引用
收藏
页码:1033 / 1040
页数:8
相关论文
共 50 条
  • [21] Complications after surgical treatment of acetabular fractures: a 5-year follow-up of 229 patients
    Natalie Lundin
    Hans E. Berg
    Anders Enocson
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 1245 - 1253
  • [22] Two years after the earthquake: Follow-up of PTSD with and without treatment
    Karamustafaliodlu, KO
    EUROPEAN NEUROPSYCHOPHARMACOLOGY, 2003, 13 : S153 - S153
  • [23] Treatment with infliximab in rheumatoid arthritis patients: Two years follow-up
    Almodovar, R
    Joven, BE
    Mateo, I
    ANNALS OF THE RHEUMATIC DISEASES, 2003, 62 : 430 - 430
  • [24] Long-term follow-up after surgical treatment of talar fractures Twenty cases with an average follow-up of 7.5 years
    Ohl, Xavier
    Harisboure, Alain
    Hemery, Xavier
    Dehoux, Emile
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (01) : 93 - 99
  • [25] Outcomes of 188 Proximal Humeral Fractures Treated with a Dedicated External Fixator with Follow-up Ranging from 2 to 12 Years
    Blonna, Davide
    Assom, Marco
    Bellato, Enrico
    Pisanu, Gabriele
    Greco, Valentina
    Marmotti, Antonio
    Rossi, Roberto
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (18): : 1654 - 1661
  • [26] Muscle MRI in two SMA patients on nusinersen treatment: A two years follow-up
    Barp, Andrea
    Carraro, Elena
    Albamonte, Emilio
    Salmin, Francesca
    Lunetta, Christian
    Comi, Giacomo Pietro
    Messina, Carmelo
    Albano, Domenico
    Chianca, Vito
    Sconfienza, Luca Maria
    Mercuri, Eugenio Maria
    Sansone, Valeria Ada
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2020, 417
  • [27] Comparison of “Bilboquet” device and locking plate for surgical treatment of proximal humerus complex fractures at two years follow-up
    Yaniv Bismuth
    Adeline Cambon-Binder
    Alain Sautet
    Levon Doursounian
    Thomas Gregory
    Claire Bastard
    International Orthopaedics, 2021, 45 : 1811 - 1816
  • [28] Comparison of "Bilboquet" device and locking plate for surgical treatment of proximal humerus complex fractures at two years follow-up
    Bismuth, Yaniv
    Cambon-Binder, Adeline
    Sautet, Alain
    Doursounian, Levon
    Gregory, Thomas
    Bastard, Claire
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (07) : 1811 - 1816
  • [29] Acute Total Hip Arthroplasty for the Treatment of Acetabular Fractures: A Retrospective Study With a Six-Year Follow-Up
    Sarantis, Michail
    Stasi, Sophia
    Milaras, Christos
    Tzefronis, Dimitrios
    Lepetsos, Panagiotis
    Macheras, George
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (08)
  • [30] Ten Years' Follow-Up on Combined Palmar and Dorsal Internal Fixation of Complex Distal Radius Fractures
    Iselin, Lukas Daniel
    Massy-Budmiger, Anne-Sophie
    Droeser, Raoul A.
    Mett, Tobias R.
    Babst, Reto
    Rikli, Daniel A.
    MEDICINE, 2016, 95 (18) : e3509