Control of radiofrequency ablation in ex vivo human liver tissue using 3D echo decorrelation imaging feedback

被引:2
|
作者
Ghahramani, Elmira Z. [1 ]
Grimm, Peter D. [1 ]
Saremi, Bahar [1 ]
Wang, Jiang [2 ]
Ahmad, Syed A. [3 ]
Shah, Shimul A. [3 ]
Quillin, R. Cutler [3 ]
Patel, Sameer H. [3 ]
Rao, Marepalli B. [4 ]
Mast, T. Douglas [1 ]
机构
[1] Univ Cincinnati, Dept Biomed Engn, Cincinnati, OH 45221 USA
[2] Univ Cincinnati, Dept Pathol & Lab Med, Cincinnati, OH USA
[3] Univ Cincinnati, Dept Surg, 231 Bethesda Ave, Cincinnati, OH 45267 USA
[4] Univ Cincinnati, Dept Environm Hlth, Cincinnati, OH USA
关键词
Echo decorrelation imaging; thermal ablation monitoring; 3-dimensional ultrasound; integrated backscatter; liver cancer; real-time control;
D O I
10.1109/IUS52206.2021.9593465
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Limitations of radiofrequency ablation (RFA) treatment for nonresectable liver cancer could potentially be overcome by monitoring and controlling RFA to confirm complete treatment. Echo decorrelation imaging has been shown to predict local thermal ablation and to successfully control ablation in animal liver and tumor tissue, both ex vivo and in vivo. Toward translation of this monitoring and control approach to clinical liver tumor ablation, this study investigated control of RFA in ex vivo human liver tissue using 3D echo decorrelation imaging. Human liver tissue, including postmortem normal liver as well as explanted cirrhotic and fatty liver, was ablated using a clinical RFA system. During ablation, 3D echo decorrelation images were constructed from paired sequential volumes of acquired echo data. For controlled RFA trials, ablation was ceased automatically after cumulative echo decorrelation, spatially averaged within a spherical ROI matching the planned ablation zone, exceeded a predetermined threshold. This control algorithm was tested in N=6 controlled ablation trials, of which 5 attained the predetermined decorrelation threshold. 3D echo decorrelation maps were compared to segmented ablation zones, using receiver operating characteristic (ROC) curve analysis. To assess the effect of image-based feedback control on treatment reliability, ablation volumes and rates, as well as Dice coefficients for measured vs. targeted ablation zones, were statistically compared for controlled vs. uncontrolled trials. Results suggest potential for 3D echo decorrelation imaging as a monitoring and control approach for clinical ablation of liver tumors.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Correlation between CT Number shift and tissue temperature change during radiofrequency ablation: an ex-vivo study using bovine liver
    Lee, Dong Leng
    Wong, Yin How
    Cheah, Peng Long
    Tan, Daryl
    Lim, Kok Sing
    Ahmad, Azlan Che
    Sulaiman, Norshazriman
    Abdullah, Basri Johan Jeet
    Yeong, Chai Hong
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [42] Ablation Monitoring with Elastography: 2D In-vivo and 3D Ex-vivo Studies
    Rivaz, Hassan
    Fleming, Ioana
    Assumpcao, Lia
    Fichtinger, Gabor
    Hamper, Ulrike
    Choti, Michael
    Hager, Gregory
    Boctor, Emad
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT II, PROCEEDINGS, 2008, 5242 : 458 - 466
  • [43] An ex vivo study on radiofrequency tissue ablation: increased lesion size by using an "expandable-wet" electrode
    Miao, Y
    Ni, YC
    Yu, J
    Zhang, H
    Baert, A
    Marchal, G
    EUROPEAN RADIOLOGY, 2001, 11 (09) : 1841 - 1847
  • [44] An ex vivo study on radiofrequency tissue ablation: increased lesion size by using an "expandable-wet" electrode
    Yi Miao
    Yicheng Ni
    Jie Yu
    Hao Zhang
    Albert Baert
    Guy Marchal
    European Radiology, 2001, 11 : 1841 - 1847
  • [45] Myelin water imaging of in vivo and ex vivo human brains using multi-echo gradient echo at 3T and 7T
    Xu, Guojun
    Zhao, Zhiyong
    Zhu, Qinfeng
    Zhu, Keqing
    Zhang, Jing
    Wu, Dan
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 803 - 813
  • [46] Design and Ex Vivo Evaluation of a 3D High Intensity Focused Ultrasound System for Tumor Treatment with Tissue Ablation
    Lweesy, K.
    Fraiwan, L.
    Al-Shalabi, M.
    Mohammad, L.
    Al-Oglah, R.
    26TH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE: SBEC 2010, 2010, 32 : 556 - 559
  • [47] Multipolar radiofrequency ablation using 4-6 applicators simultaneously: A study in the ex vivo bovine liver
    Stoffner, Rudolf
    Kremser, Christian
    Schullian, Peter
    Haidu, Marion
    Widmann, Gerlig
    Bale, Reto J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) : 2568 - 2575
  • [48] Feasibility of in vivo myelin water imaging using 3D multigradient-echo pulse sequences
    Lenz, C.
    Klarhoefer, M.
    Scheffler, K.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (02) : 523 - 528
  • [49] 3D EX VIVO PATIENT TISSUE PLATFORM FOR IMMUNOONCOLOGY DRUG TESTING
    Basten, Sander
    Beztsinna, Nataliia
    Grillet, Fanny
    Yan, Kuan
    Meesters, Niels
    van der Meer, Donny
    Spanjaard, Emma
    Vader, Willemijn
    Price, Leo
    JOURNAL FOR IMMUNOTHERAPY OF CANCER, 2022, 10 : A212 - A212
  • [50] Real-time Conductivity Imaging of Temperature and Tissue Property Changes During Radiofrequency Ablation: An Ex Vivo Model Using Weighted Frequency Difference
    Wi, Hun
    McEwan, Alistair Lee
    Lam, Vincent
    Kim, Hyung Joong
    Woo, Eung Je
    Oh, Tong In
    BIOELECTROMAGNETICS, 2015, 36 (04) : 277 - 286