摘要
This paper presents a nondestructive corrosion damage detection method for reinforced concrete structures based on the analysis of the electromagnetic signature of the steel rebar corrosion. The signature of the corrosion on the scattered field upon microwave illumination is first numerically analyzed. First-order quality factor parameters, the energy and the mean propagation delay, are proposed to quantify the corrosion amount in the structure. To validate the model, low-profile ultra-wide-band antennas (3-12 GHz) are fabricated and measured. Measurements on 12 reinforced concrete samples with induced corrosion are performed, using three different antenna setups. The experiments demonstrate a good correlation between an increase in the corrosion amount with a decrease in the energy and an increase in the time delay of the propagated signal.
引用
收藏
页码:1090 / 1098
页数:9
相关论文
共 50 条
  • [31] Editorial: Corrosion of Reinforced Concrete Structures
    Bastidas, David M.
    Bastidas, Jose M.
    FRONTIERS IN MATERIALS, 2020, 7 (07):
  • [32] Stop corrosion of reinforced concrete structures
    J.E. Bennett Consultants, Inc, Chardon, United States
    Chem Eng Prog, 7 (77-81):
  • [33] APPLICATION OF AN ATMOSPHERIC CORROSION MODEL TO THE PREDICTION OF INDUCED DAMAGE IN REINFORCED CONCRETE STRUCTURES
    Millard, Alain
    Leyre, Valerie
    L'Hostis, Valerie
    RILEM WORKSHOP ON LONG-TERM PERFORMANCE OF CEMENTITIOUS BARRIERS AND REINFORCED CONCRETE IN NUCLEAR POWER PLANTS AND WASTE MANAGEMENT, 2009, 64 : 175 - +
  • [34] Service life of reinforced concrete structures with corrosion damage due to chloride attack
    Suwito, A
    Xi, YP
    LIFE-CYCLE PERFORMANCE OF DETERIORATING STRUCTURES: ASSESSMENT, DESIGN, AND MANAGEMENT, 2004, : 207 - 218
  • [35] Monitoring corrosion in reinforced concrete structures
    Kung, Peter
    Comanici, Maria I.
    SENSORS FOR EXTREME HARSH ENVIRONMENTS, 2014, 9113
  • [37] Nondestructive Evaluation of Rebar Corrosion-Induced Damage in Concrete through Ultrasonic Imaging
    Ghosh, Debdutta
    Kumar, Rahul
    Ganguli, Abhijit
    Mukherjee, Abhijit
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2020, 32 (10)
  • [38] Nondestructive techniques to investigate corrosion status in concrete structures
    Carino, Nicholas J.
    Journal of Performance of Constructed Facilities, 1999, 13 (03): : 96 - 106
  • [39] Monitoring DIAMOND device for corrosion state evaluation of reinforced concrete structures
    Samson, Gabriel
    Deby, Fabrice
    Garciaz, Jean-Luc
    Perrin, Jean-Louis
    INTERNATIONAL CONFERENCE ON CONCRETE REPAIR, REHABILITATION AND RETROFITTING (ICCRRR 2018), 2018, 199
  • [40] Evaluation of passivation method and corrosion inhibitors for steel reinforced concrete structures
    Brown, R
    Lee, KW
    Cao, Y
    NONDESTRUCTIVE EVALUATION OF BRIDGES AND HIGHWAYS III, 1999, 3587 : 266 - 285