Analysis of the Electromagnetic Signature of Reinforced Concrete Structures for Nondestructive Evaluation of Corrosion Damage

被引:44
|
作者
Roqueta, Gemma [1 ]
Jofre, Lluis [1 ]
Feng, Maria Q. [2 ]
机构
[1] Univ Politecn Cataluna, ES-08034 Barcelona, Spain
[2] Columbia Univ, New York, NY 10027 USA
关键词
Corrosion; dielectric materials; microwave antennas; microwave imaging; microwave propagation; nondestructive testing; reflection; time domain analysis;
D O I
10.1109/TIM.2011.2174106
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a nondestructive corrosion damage detection method for reinforced concrete structures based on the analysis of the electromagnetic signature of the steel rebar corrosion. The signature of the corrosion on the scattered field upon microwave illumination is first numerically analyzed. First-order quality factor parameters, the energy and the mean propagation delay, are proposed to quantify the corrosion amount in the structure. To validate the model, low-profile ultra-wide-band antennas (3-12 GHz) are fabricated and measured. Measurements on 12 reinforced concrete samples with induced corrosion are performed, using three different antenna setups. The experiments demonstrate a good correlation between an increase in the corrosion amount with a decrease in the energy and an increase in the time delay of the propagated signal.
引用
收藏
页码:1090 / 1098
页数:9
相关论文
共 50 条
  • [21] Inspection of Steel Bars Corrosion in Reinforced Concrete Structures by Nondestructive Ground Penetrating Radar
    Chang, Che-Way
    Tsai, Che-An
    Shiau, Yan-Chyuan
    APPLIED SCIENCES-BASEL, 2022, 12 (11):
  • [22] Evaluation of residual strength of corrosion damaged reinforced concrete structures
    Nepal, Jaya
    Chen, Hua-Peng
    LIFE-CYCLE OF STRUCTURAL SYSTEMS: DESIGN, ASSESSMENT, MAINTENANCE AND MANAGEMENT, 2015, : 443 - 450
  • [23] Avoiding Corrosion Damage in Reinforced Concrete
    Gaidis, James M.
    Rosenberg, Arnie M.
    Concrete International, 2001, 23 (11) : 80 - 83
  • [24] Simulation of ultrasonic and electromagnetic nondestructive evaluation of corrosion
    Spies, M
    Yashan, A
    Kropas-Hughes, CV
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 22A AND 22B, 2003, 20 : 367 - 374
  • [25] Damage detection of carbon reinforced composites using nondestructive evaluation with ultrasound and electromagnetic methods
    Savin, A.
    Barsanescu, P. D.
    Vizureanu, P.
    Stanciu, M. D.
    Curtu, I.
    Iftimie, N.
    Steigmann, R.
    INTERNATIONAL CONFERENCE ON INNOVATIVE RESEARCH - ICIR EUROINVENT 2016, 2016, 133
  • [26] Nondestructive Evaluation of Thick Concrete Structures
    Clayton, Dwight A.
    SMART MATERIALS AND NONDESTRUCTIVE EVALUATION FOR ENERGY SYSTEMS 2015, 2015, 9439
  • [27] EFFECTS OF CORROSION AND AFTERSHOCK ON STRUCTURAL DAMAGE AND FRAGILITY OF REINFORCED CONCRETE FRAME STRUCTURES
    Zhou Z.
    Yu X.-H.
    Lyu D.-G.
    Han M.
    Gongcheng Lixue/Engineering Mechanics, 2023, 40 (09): : 203 - 213and256
  • [28] Effects of Corrosion on Reinforced Concrete Structures
    Bossio, Antonio
    Fabbrocino, Francesco
    Lignola, Gian Piero
    Monetta, Tullio
    Bellucci, Francesco
    Manfredi, Gaetano
    Prota, Andrea
    WORLD HERITAGE AND DEGRADATION: SMART DESIGN, PLANNING AND TECHNOLOGIES, 2016, : 941 - 949
  • [29] CORROSION MONITORING IN REINFORCED CONCRETE STRUCTURES
    Nygaard, Peter V.
    Klinghoffer, Oskar
    ADVANCES IN CONCRETE STRUCTURAL DURABILITY, PROCEEDINGS OF ICDCS2008, VOLS 1 AND 2, 2008, : 1219 - 1228
  • [30] Stop corrosion of reinforced concrete structures
    Bennett, JE
    CHEMICAL ENGINEERING PROGRESS, 1998, 94 (07) : 77 - 81