Preoperative thoracic false lumen branches are predictors of aortic enlargement after stent grafting for DeBakey IIIb aortic dissection

被引:29
|
作者
Liu, Feng [1 ]
Ge, Yang Yang [1 ]
Guo, Wei [1 ]
Liu, Xiao Ping [1 ]
Jia, Xin [1 ]
Xiong, Jiang [1 ]
Ma, Xiao Hui [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Vasc & Endovasc Surg, 28 Fuxing Rd, Beijing 100853, Peoples R China
来源
关键词
aortic dissection; TEVAR; aortic remodeling; thoracic false lumen branches; ENDOVASCULAR TREATMENT; B DISSECTION; COMPETING RISK; REPAIR; THROMBOSIS; MULTICENTER; PLACEMENT; TRIAL; TEVAR; ANEURYSMS;
D O I
10.1016/j.jtcvs.2017.09.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The study objective was to assess the effect of preoperative thoracic false lumen branches on thoracic aortic enlargement along the stent graft after thoracic endovascular aortic repair for DeBakey IIIb aortic dissection. Methods: From January 2011 to December 2013, 67 patients who underwent thoracic endovascular aortic repair for DeBakey IIIb aortic dissection were retrospectively investigated. We assessed preoperative thoracic false lumen branches and diameter measurements at the level of the tracheal carina. Patients with a median follow-up of 12.2 months (interquartile range, 4.3-26.6 months) were categorized into 2 groups based on a receiver operating characteristic curve analysis: group A (preoperative thoracic false lumen branches >= 8, n = 28) and group B (preoperative thoracic false lumen branches < 8, n = 39). Diameter changes over time were evaluated using a mixed model approach. A multivariate Cox regression analysis was used to study the influence of the preoperative thoracic false lumen branches on thoracic aortic enlargement along the stent graft. Results: Six patients experienced thoracic aortic enlargement along the stent graft during follow-up (6 in group A, 0 in group B). The cumulative thoracic aortic enlargement along the stent-graft rate was higher in group A than in group B (log-rank P <. 01). Diameter data showed significantly more reduction of the thoracic false lumen from preprocedure to 12 months in group B than in group A (change difference, 2.51; standard error, 0.99; P=.01). Complete false lumen thrombosis was more prominent in group B than in group A at each follow-up time point. After multivariate adjustment, preoperative thoracic false lumen branches were associated with thoracic aortic enlargement along the stent graft (hazard ratio, 2.92; 95% confidence interval, 1.06-8.01). Conclusions: Preoperative thoracic false lumen branches are amorphologic predictor of thoracic aortic enlargement along the stent graft in DeBakey IIIb aortic dissection after thoracic endovascular aortic repair.
引用
收藏
页码:21 / +
页数:12
相关论文
共 50 条
  • [41] The Level of Persistent False Lumen Perfusion Is Associated With Increased Aortic Size After Thoracic Endovascular Aortic Repair in Patients With Type B Aortic Dissection
    Kabbani, Loay
    Nadig, Jeffrey
    Ranjal, Rohit Shenoy
    Rteil, Ali
    Linchangco, Richard
    Weaver, Mitchell
    Nypaver, Timothy
    Shepard, Alexander
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (03) : E77 - E78
  • [42] Concomitant antegrade stent grafting of the descending thoracic aorta during transverse hemiarch reconstruction for acute DeBakey I aortic dissection repair improves aortic remodeling
    Sultan, Ibrahim
    Wallen, Tyler J.
    Habertheuer, Andreas
    Siki, Mary
    Arnaoutakis, George J.
    Bavaria, Joseph
    Szeto, Wilson Y.
    Milewski, Rita
    Vallabhajosyula, Prashanth
    JOURNAL OF CARDIAC SURGERY, 2017, 32 (09) : 581 - 592
  • [43] Aortic False Lumen Thrombosis Induction by Embolotherapy (AFTER) Following Endovascular Repair of Aortic Dissection
    Hofferberth, Sophie C.
    Nixon, Ian K.
    Mossop, Peter J.
    JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (04) : 538 - 545
  • [44] Predictors for thoracic aortic growth in patients with type B aortic dissection after thoracic endovascular aortic repair
    Chen, Yonghui
    Ren, Jianli
    Liu, Zongwei
    Cui, Dongsheng
    Wang, Shuaishuai
    Bi, Jiaxue
    Dai, Xiangchen
    VASCULAR, 2024,
  • [45] Outer Media Thickness at False Lumen and Secondary Aortic Dilatation After Acute Aortic Dissection
    Kinoshita, Takeshi
    Asai, Tohru
    Suzuki, Tomoaki
    ANNALS OF THORACIC SURGERY, 2022, 114 (05): : 1646 - 1654
  • [46] Hemodynamic predictors of negative false lumen remodeling after frozen elephant trunk for acute aortic dissection
    Takei, Yusuke
    Miyazaki, Shohei
    Suzuki, Kohei
    Saito, Shunsuke
    Oogaki, Hayato
    Muraoka, Yuki
    Ogasawara, Takeshi
    Tezuka, Masahiro
    Shibasaki, Ikuko
    Fukuda, Hirotsugu
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2024, 72 (06) : 376 - 386
  • [47] False lumen embolization in chronic aortic dissection promotes thoracic aortic remodeling at midterm follow-up
    Pellenc, Quentin
    Roussel, Arnaud
    De Blic, Romain
    Girault, Antoine
    Cerceau, Pierre
    Ben Abdallah, Lannis
    Milleron, Olivier
    Jondeau, Guillaume
    Castier, Yves
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (03) : 710 - 717
  • [48] Total aortic arch grafting for acute type A dissection: Analysis of residual false lumen
    Takahara, Y
    Sudo, Y
    Mogi, K
    Nakayama, M
    Sakurai, M
    ANNALS OF THORACIC SURGERY, 2002, 73 (02): : 450 - 454
  • [49] Placement of a branched stent graft into the false lumen of a chronic type B aortic dissection
    Simring, Dominic
    Raja, Jowad
    Morgan-Rowe, Luke
    Hague, Julian
    Harris, Peter L.
    Ivancev, Krassi
    JOURNAL OF VASCULAR SURGERY, 2011, 54 (06) : 1784 - 1787
  • [50] Cervical Branch Re-entry in Patients With Type A Acute Aortic Dissection is Related to a Patent False Lumen in the Aortic Arch and Enlargement After Ascending Aortic Replacement
    Yasuda, Shota
    Imoto, Kiyotaka
    Uchida, Keiji
    Soda, Susumu
    Karube, Norihisa
    Kasama, Keiichiro
    Minami, Tomoyuki
    Miyamoto, Takuma
    Uranaka, Yasuko
    Goda, Motohiko
    Suzuki, Shinichi
    Masuda, Munetaka
    CIRCULATION, 2015, 132