Preoperative thoracic false lumen branches are predictors of aortic enlargement after stent grafting for DeBakey IIIb aortic dissection

被引:29
|
作者
Liu, Feng [1 ]
Ge, Yang Yang [1 ]
Guo, Wei [1 ]
Liu, Xiao Ping [1 ]
Jia, Xin [1 ]
Xiong, Jiang [1 ]
Ma, Xiao Hui [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Vasc & Endovasc Surg, 28 Fuxing Rd, Beijing 100853, Peoples R China
来源
关键词
aortic dissection; TEVAR; aortic remodeling; thoracic false lumen branches; ENDOVASCULAR TREATMENT; B DISSECTION; COMPETING RISK; REPAIR; THROMBOSIS; MULTICENTER; PLACEMENT; TRIAL; TEVAR; ANEURYSMS;
D O I
10.1016/j.jtcvs.2017.09.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The study objective was to assess the effect of preoperative thoracic false lumen branches on thoracic aortic enlargement along the stent graft after thoracic endovascular aortic repair for DeBakey IIIb aortic dissection. Methods: From January 2011 to December 2013, 67 patients who underwent thoracic endovascular aortic repair for DeBakey IIIb aortic dissection were retrospectively investigated. We assessed preoperative thoracic false lumen branches and diameter measurements at the level of the tracheal carina. Patients with a median follow-up of 12.2 months (interquartile range, 4.3-26.6 months) were categorized into 2 groups based on a receiver operating characteristic curve analysis: group A (preoperative thoracic false lumen branches >= 8, n = 28) and group B (preoperative thoracic false lumen branches < 8, n = 39). Diameter changes over time were evaluated using a mixed model approach. A multivariate Cox regression analysis was used to study the influence of the preoperative thoracic false lumen branches on thoracic aortic enlargement along the stent graft. Results: Six patients experienced thoracic aortic enlargement along the stent graft during follow-up (6 in group A, 0 in group B). The cumulative thoracic aortic enlargement along the stent-graft rate was higher in group A than in group B (log-rank P <. 01). Diameter data showed significantly more reduction of the thoracic false lumen from preprocedure to 12 months in group B than in group A (change difference, 2.51; standard error, 0.99; P=.01). Complete false lumen thrombosis was more prominent in group B than in group A at each follow-up time point. After multivariate adjustment, preoperative thoracic false lumen branches were associated with thoracic aortic enlargement along the stent graft (hazard ratio, 2.92; 95% confidence interval, 1.06-8.01). Conclusions: Preoperative thoracic false lumen branches are amorphologic predictor of thoracic aortic enlargement along the stent graft in DeBakey IIIb aortic dissection after thoracic endovascular aortic repair.
引用
收藏
页码:21 / +
页数:12
相关论文
共 50 条
  • [31] Antegrade Thoracic Stent Grafting During Repair of Acute DeBakey I Dissection Prevents Development of Thoracoabdominal Aortic Aneurysms
    Pochettino, Alberto
    Brinkman, William T.
    Moeller, Patrick
    Szeto, Wilson Y.
    Moser, William
    Cornelius, Katherine
    Bowen, Frank W.
    Woo, Y. Joseph
    Bavaria, Joseph E.
    ANNALS OF THORACIC SURGERY, 2009, 88 (02): : 482 - 490
  • [32] Thoracic Endovascular Aortic Repair for Descending Thoracic Aortic Enlargement Following Repair With the Ascyrus Medical Dissection Stent
    EL-Andari, Ryaan
    Bozso, Sabin J.
    O'Brien, Devin
    Chung, Jennifer
    Ouzounian, Maral
    Moon, Michael C.
    CANADIAN JOURNAL OF CARDIOLOGY, 2023, 39 (11) : 1698 - 1700
  • [33] FATE OF THE DISTAL NECK AFTER STENT-GRAFTING FOR TYPE IIIB AORTIC DISSECTION: A WORD OF CAUTION
    Dagenais, F.
    Albert, G.
    Mohammadi, S.
    Voisine, P.
    Dumont, E.
    CANADIAN JOURNAL OF CARDIOLOGY, 2012, 28 (05) : S123 - S124
  • [34] Outcomes of stent-graft treatment of false lumen in aortic dissection - Comment
    Daily, PO
    CIRCULATION, 1998, 98 (19) : II311 - II312
  • [35] Thoracic Endovascular Repair for Chronic Aortic Dissection with Distal Landing in the False Lumen
    Oue, Kensuke
    Kato, Noriyuki
    Tanaka, Satofumi
    Noda, Yoshihiro
    Miyake, Yoichiro
    Higashigawa, Takatoshi
    Okabe, Manabu
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (10) : 1574 - 1576
  • [36] Impact of Endovascular False Lumen Embolization on Thoracic Aortic Remodeling in Chronic Dissection
    Miletic, Kyle G.
    Kindzelski, Bogdan A.
    Hodges, Kevin E.
    Beach, Jocelyn
    Tong, Michael Z.
    Bakaeen, Faisal
    Johnston, Douglas R.
    Desai, Milind
    Lyden, Sean
    Roselli, Eric E.
    ANNALS OF THORACIC SURGERY, 2021, 111 (02): : 495 - 501
  • [37] False Lumen Embolization to Treat Disseminated Intravascular Coagulation After Thoracic Endovascular Aortic Repair of Type B Aortic Dissection
    Mendes, Bernardo C.
    Oderich, Gustavo S.
    Erben, Young
    Reed, Nanette R.
    Pruthi, Rajiv K.
    JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (06) : 938 - 941
  • [38] Temporal pattern of aortic remodelling after endovascular treatment for chronic DeBakey IIIb dissection
    Kim, Tae-Hoon
    Song, Suk-Won
    Heo, Woon
    Lee, Kwang-Hun
    Yoo, Kyung-Jong
    Lee, Hye Sun
    Cho, Bum-Koo
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 31 (02) : 232 - 238
  • [39] Coil embolization of persistent false lumen after stent graft repair of type B aortic dissection
    San Norberto, Enrique Maria
    Manuel Gutierrez, Vicente
    Taylor, James
    Vaquero, Carlos
    JOURNAL OF VASCULAR SURGERY, 2011, 54 (01) : 201 - 204
  • [40] Predictors of false lumen thrombosis in type B aortic dissection treated with TEVAR
    Tolenaar, Jip L.
    Kern, John A.
    Jonker, Frederik H. W.
    Cherry, Kenneth J.
    Tracci, Megan C.
    Angle, John F.
    Sabri, Saher
    Trimarchi, Santi
    Strider, David
    Alaiwaidi, Gorav
    Upchurch, Gilbert R., Jr.
    ANNALS OF CARDIOTHORACIC SURGERY, 2014, 3 (03) : 255 - 263