Moria M2 single use microkeratome head in 100 consecutive LASIK procedures

被引:0
|
作者
Kanellopoulos, AJ
Pe, LH
Kleiman, L
机构
[1] LaserVis Gr Eye Inst, Pyrgos Athninon, Athens 11527, Greece
[2] Manhattan Eye Ear & Throat Hosp, Dept Ophthalmol, New York, NY 10021 USA
[3] NYU, Sch Med, Dept Ophthalmol, New York, NY USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the safety and efficacy of the Moria M2 single use 130 microkeratome head in consecutive LASIK procedures for correction of myopia and myopic astigmatism. METHODS: One hundred eyes of 55 patients underwent LASIK in which the flaps were created with the Moria M2 microkeratome using the single use 130 head and excimer laser ablation was done with the Allegretto Wavelight laser. Flap parameters measured were: thickness, diameter, hinge length, and overall quality. Preoperative uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), refraction, wavefront aberrations, and low contrast sensitivity were compared to postoperative values at 6-month follow-up. RESULTS: Mean flap thickness was 145 +/- 17.5 mu m, mean flap diameter was 8.5 +/- 0.40 mm, and mean hinge cord length was 4.05 +/- 0.35 mm. At 6-month follow-up, UCVA improved from 20/200 (+/- 0.24) to 20/18.5 (+/- 0.12) and BSCVA improved from 20/20.5 (+/- 0.18) to 20/17.5 (+/- 0.11). CONCLUSIONS: The Moria M2 single use 130 microkeratome head appears to be safe and effective in performing LASIK procedures.
引用
收藏
页码:476 / 479
页数:4
相关论文
共 50 条
  • [1] Flap thickness in LASIK procedures utilizing the Moria M2 microkeratome
    Muallem, MS
    Yoo, SH
    Romano, ACO
    Culbertson, WW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U477 - U477
  • [2] LASIK flap characteristics using the Moria M2 microkeratome with the 90-μm single use head
    Aslanides, Ioannis M.
    Tsiklis, Nikolaos S.
    Astyrakakis, Nikolaos I.
    Pallikaris, Ioannis G.
    Jankov, Mirko R.
    JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (01) : 45 - 49
  • [3] Corneal flap thickness with the Moria M2 single-use head 90 microkeratome
    Huhtala, Anne
    Pietila, Juhani
    Makinen, Petri
    Suominen, Sakari
    Seppanen, Matti
    Uusitalo, Hannu
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (04): : 401 - 406
  • [4] Prospective evaluation of the M2 disposable 130 head in 100 consecutive LASIK procedures
    Kleiman, LZ
    Kanellopoulos, AJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U25 - U25
  • [5] Confocal microscopy comparison IntraLase femtosecond laser and Moria M2 Microkeratome in LASIK
    Javaloy, Jaime
    Vidal, Maria T.
    Abdelrahman, Ayman M.
    Artola, Alberto
    Alio, Jorge L.
    JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (02) : 178 - 187
  • [6] Corneal flap thickness with the Moria M2™ microkeratome and Med-Logics calibrated LASIK blades
    Pietila, Juhani
    Huhtala, Anne
    Makinen, Petri
    Seppanen, Matti
    Jaaskelainen, Markus
    Uusitalo, Hannu
    ACTA OPHTHALMOLOGICA, 2009, 87 (07) : 754 - 758
  • [7] Evaluating corneal flap thickness following laser in situ keratomileusis with the moria M2 90-μm single-use-head microkeratome
    Ming-hui Zhao
    Jun Zou
    Qin-yi Cheng
    Jian-guo Yang
    Qiang Wu
    Japanese Journal of Ophthalmology, 2008, 52 : 505 - 506
  • [8] Evaluating corneal flap thickness following laser in situ keratomileusis with the moria M2 90-μm single-use-head microkeratome
    Zhao, Ming-hui
    Zou, Jun
    Cheng, Qin-yi
    Yang, Jian-guo
    Wu, Qiang
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2008, 52 (06) : 505 - 506
  • [9] Confocal Microscopy of disposable and nondisposable heads for the Moria M2 microkeratome
    Javaloy, J
    Vidal, MT
    Ruiz-Moreno, JM
    Alió, JL
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (01) : 28 - 33
  • [10] Bilateral comparison of corneal flap dimensions with the moria M2 reusable head and single use head microkeratomes
    Pietilä, J
    Mäkinen, P
    Suominen, S
    Huhtala, A
    Uusitalo, H
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (04) : 354 - 357