Moria M2 single use microkeratome head in 100 consecutive LASIK procedures

被引:0
|
作者
Kanellopoulos, AJ
Pe, LH
Kleiman, L
机构
[1] LaserVis Gr Eye Inst, Pyrgos Athninon, Athens 11527, Greece
[2] Manhattan Eye Ear & Throat Hosp, Dept Ophthalmol, New York, NY 10021 USA
[3] NYU, Sch Med, Dept Ophthalmol, New York, NY USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the safety and efficacy of the Moria M2 single use 130 microkeratome head in consecutive LASIK procedures for correction of myopia and myopic astigmatism. METHODS: One hundred eyes of 55 patients underwent LASIK in which the flaps were created with the Moria M2 microkeratome using the single use 130 head and excimer laser ablation was done with the Allegretto Wavelight laser. Flap parameters measured were: thickness, diameter, hinge length, and overall quality. Preoperative uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), refraction, wavefront aberrations, and low contrast sensitivity were compared to postoperative values at 6-month follow-up. RESULTS: Mean flap thickness was 145 +/- 17.5 mu m, mean flap diameter was 8.5 +/- 0.40 mm, and mean hinge cord length was 4.05 +/- 0.35 mm. At 6-month follow-up, UCVA improved from 20/200 (+/- 0.24) to 20/18.5 (+/- 0.12) and BSCVA improved from 20/20.5 (+/- 0.18) to 20/17.5 (+/- 0.11). CONCLUSIONS: The Moria M2 single use 130 microkeratome head appears to be safe and effective in performing LASIK procedures.
引用
收藏
页码:476 / 479
页数:4
相关论文
共 50 条
  • [21] Thin flap laser in situ keratomileusis:: Flap dimensions with the Moria LSK-One manual microkeratome using the 100-μm head
    Duffey, RJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (06): : 1159 - 1162
  • [22] Incidence of diffuse lamellar keratitis after laser in situ keratomileusis associated with the IntraLase 15 kHz femtosecond laser and Moria M2 microkeratome
    Gil-Cazorla, Raquel
    Teus, Miguel A.
    Benito-Llopis, Laura Cle
    Fuentes, Irene
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (01): : 28 - 31
  • [23] Moria M2自动微型角膜刀在LASIK近视矫正手术中的应用
    刘百臣
    樊郑军
    彭秀军
    高原
    刘海林
    陈晓莉
    贾泽昊
    关延荣
    海军总医院学报, 2005, (01) : 14 - 16
  • [24] Visumax femtolasik versus Moria M2 microkeratome in mild to moderate myopia: efficacy, safety, predictability, aberrometric changes and flap thickness predictability
    Torky, Magda A.
    Al Zafiri, Yousif A.
    Khattab, Abeer M.
    Farag, Rania K.
    Awad, Eman A.
    BMC OPHTHALMOLOGY, 2017, 17
  • [25] Visumax femtolasik versus Moria M2 microkeratome in mild to moderate myopia: efficacy, safety, predictability, aberrometric changes and flap thickness predictability
    Magda A Torky
    Yousif A Al Zafiri
    Abeer M Khattab
    Rania K Farag
    Eman A Awad
    BMC Ophthalmology, 17
  • [26] Initial hyperopic LASIK experience with the ALLEGRETTO-WAVE and the M2 in 120 consecutive eyes
    Conway, JL
    Papas, E
    Kanellopoulas, AJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U23 - U23
  • [27] Effect of suction on macular thickness and retinal nerve fiber layer thickness during LASIK used femtosecond laser and Mona M2 microkeratome
    Zhang, Jing
    Zhou, Yue-Hua
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (04) : 777 - 783
  • [28] Moria M2型一次性90刀头在LASIK中的应用观察
    左文渊
    白桂花
    王兴存
    武文治
    孟志强
    白求恩军医学院学报, 2011, 9 (05) : 338 - 339
  • [29] Flap thickness rate and reproducibility of the B&L Hansatome, Moria CB, Moria M2 and Alcon SKBM microkeratomes
    Miranda, DB
    Smith, S
    Krueger, RR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U479 - U479
  • [30] Axial length and IOP changes with application of the IntraLase and moria M2 suction rings
    Culbertson, WW
    Marangon, F
    Yoo, SH
    Acosta, CA
    Nose, I
    Superfine, P
    Parel, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46