Confocal microscopy comparison IntraLase femtosecond laser and Moria M2 Microkeratome in LASIK

被引:0
|
作者
Javaloy, Jaime
Vidal, Maria T.
Abdelrahman, Ayman M.
Artola, Alberto
Alio, Jorge L.
机构
[1] Miguel Hernandez Univ, Sch Med, Inst Oftalmol Alicante, Dept Cornea & Refract Surg,VISSUM, Alicante, Spain
[2] Zagazig Univ, Fac Med, Dept Ophthalmol, Zagazig, Egypt
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To analyze the quality of LASIK flaps created using a femtosecond laser or a mechanical microkeratome. METHODS: A prospective study of consecutive bilateral LASIK flaps (100 patients) created with a 15 kHz femtosecond laser (IntraLase) or with a mechanical microkeratome (Moria M2) was performed. Outcome measures included visual and refractive outcomes, flap. dimensions, and intraoperative complications. The first consecutive ten patients (20 eyes) were examined using confocal microscopy 1 and 3 months following surgery. RESULTS: No significant differences were noted in the visual outcomes between groups (t test, P > .05 for all comparisons). Analysis of superficial measurements revealed more round flaps and greater predictability in surface dimensions for the femtosecond laser group (t test, P = .016). Mean deviation of flap thickness from target was the same for both instruments, 10 pm, with greater variability for the mechanical microkeratome. The incidence of diffuse lamellar keratitis was significantly greater in the femtosecond laser group (17%) than in the mechanical group (0%) (chi-square test, P < .001). Confocal microscopy revealed a higher wound healing opacity index in the femtosecond laser group. CONCLUSIONS: Although the clinical results are similar, the femtosecond laser produces LASIK flaps with more accurate dimensions compared to the mechanical microkeratome.
引用
收藏
页码:178 / 187
页数:10
相关论文
共 50 条
  • [1] A comparative confocal microscopy analysis after LASIK with the IntraLase femtosecond laser vs Hansatome microkeratome
    Ramirez, Manuel
    Hernandez-Quintela, Everardo
    Naranjo-Tackman, Ramon
    JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (03) : 305 - 307
  • [2] Confocal Microscopy of disposable and nondisposable heads for the Moria M2 microkeratome
    Javaloy, J
    Vidal, MT
    Ruiz-Moreno, JM
    Alió, JL
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (01) : 28 - 33
  • [3] Comparison of the Ziemer FEMTO LDV Femtosecond Laser and Moria M2 Mechanical Microkeratome
    Zhou, Yuehua
    Zhang, Jing
    Tian, Lei
    Zhai, Changbin
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (03) : 189 - U114
  • [4] In vivo corneal confocal microscopy comparison of intralase femtosecond laser and mechanical microkeratome for laser in situ keratomileusis
    Sonigo, Bertrand
    Iordanidou, Vasiliki
    Chong-Sit, Didier
    Auclin, Francois
    Ancel, Jean Marc
    Labbe, Antoine
    Baudouin, Christophe
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (07) : 2803 - 2811
  • [5] Incidence of diffuse lamellar keratitis after laser in situ keratomileusis associated with the IntraLase 15 kHz femtosecond laser and Moria M2 microkeratome
    Gil-Cazorla, Raquel
    Teus, Miguel A.
    Benito-Llopis, Laura Cle
    Fuentes, Irene
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (01): : 28 - 31
  • [6] Flap thickness in LASIK procedures utilizing the Moria M2 microkeratome
    Muallem, MS
    Yoo, SH
    Romano, ACO
    Culbertson, WW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U477 - U477
  • [7] Effect of suction on macular thickness and retinal nerve fiber layer thickness during LASIK used femtosecond laser and Moria M2 microkeratome
    Jing Zhang
    Yue-Hua Zhou
    International Journal of Ophthalmology, 2015, (04) : 777 - 783
  • [8] Moria M2 single use microkeratome head in 100 consecutive LASIK procedures
    Kanellopoulos, AJ
    Pe, LH
    Kleiman, L
    JOURNAL OF REFRACTIVE SURGERY, 2005, 21 (05) : 476 - 479
  • [9] Comparison of the IntraLase femtosecond laser and mechanical microkeratome for laser in situ keratomileusis
    Lim, Taehyung
    Yang, Sungjae
    Kim, Myoung Joon
    Tchah, Hungwon
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) : 833 - 839
  • [10] LASIK flap characteristics using the Moria M2 microkeratome with the 90-μm single use head
    Aslanides, Ioannis M.
    Tsiklis, Nikolaos S.
    Astyrakakis, Nikolaos I.
    Pallikaris, Ioannis G.
    Jankov, Mirko R.
    JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (01) : 45 - 49