An amperometric biosensor based on poly(l-aspartic acid), nanodiamond particles, carbon nanofiber, and ascorbate oxidase-modified glassy carbon electrode for the determination ofl-ascorbic acid

被引:32
|
作者
Kacar, Ceren [1 ]
Erden, Pinar Esra [2 ]
机构
[1] Ankara Univ, Fac Sci, Dept Chem, TR-06100 Ankara, Turkey
[2] Ankara Haci Bayram Veli Univ, Polatli Fac Sci & Arts, Dept Chem, TR-06900 Ankara, Turkey
关键词
Amperometric biosensor; l-Ascorbic acid; Carbon nanofiber; Poly(l-aspartic acid); Nanodiamond; AGRICULTURAL APPLICATION; ELECTROCHEMICAL SENSOR; GRAPHITE ELECTRODE; L-LYSINE; COMPOSITE; NANOTUBES; IMMOBILIZATION; FABRICATION; NANOCOMPOSITE; NANOPARTICLES;
D O I
10.1007/s00216-020-02747-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An amperometricl-ascorbic acid biosensor utilizing ascorbate oxidase (AOx) immobilized onto poly(l-aspartic acid) (P(l-Asp)) film was fabricated on carbon nanofiber (CNF) and nanodiamond particle (ND)-modified glassy carbon electrode (GCE). Effects of AOx, ND, and CNF amounts were investigated by monitoring the response currents of the biosensor at different amounts of AOx, ND, and CNF. The electropolymerization step ofl-aspartic acid on CNF-ND/GCE surface was also optimized. Scanning electron microscopy (SEM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) techniques were used to enlighten the modification steps of the biosensor. The effects of pH and applied potential were studied in detail to achieve the best analytical performance. Under optimized experimental conditions, the AOx/P(L-Asp)/ND-CNF/GCE biosensor showed a linear response tol-ascorbic acid in the range of 2.0 x 10(-7)-1.8 x 10(-3) M with a detection limit of 1.0 x 10(-7) M and sensitivity of 105.0 mu AmM-1 cm(-2). The novel biosensing platform showed good reproducibility and selectivity. The strong interaction between AOx and the P(l-Asp)/ND-CNF matrix was revealed by the high repeatability (3.4%) and good operational stability. The AOx/P(l-Asp)/ND-CNF/GCE biosensor was successfully applied to the determination ofl-ascorbic acid in vitamin C effervescent tablet and pharmaceutical powder containing ascorbic acid with good results, which makes it a promising approach for quantification ofl-ascorbic acid.
引用
收藏
页码:5315 / 5327
页数:13
相关论文
共 50 条
  • [41] Application of a glassy carbon electrode modified with poly(glutamic acid) in caffeic acid determination
    Santos, DP
    Bergamini, MF
    Fogg, AG
    Zanoni, MVB
    MICROCHIMICA ACTA, 2005, 151 (1-2) : 127 - 134
  • [42] Application of a Glassy Carbon Electrode Modified with Poly(Glutamic Acid) in Caffeic Acid Determination
    Daniela P. Santos
    Marcio F. Bergamini
    Arnold G. Fogg
    Maria Valnice B. Zanoni
    Microchimica Acta, 2005, 151 : 127 - 134
  • [43] Electrochemical Determination of Bisphenol A Based on Poly(Chromotropic Acid) Modified Glassy Carbon Electrode
    Filik, Hayati
    Avan, Asiye Aslihan
    CURRENT ANALYTICAL CHEMISTRY, 2017, 13 (06) : 464 - 473
  • [44] Amperometric Ascorbic Acid Biosensors Based on the Oxygen and Glassy Carbon Electrodes Modified with Ascorbate Oxidase Immobilized-silk Fibroin/polyethylene Glycol Membrane
    Ratanasongtham, Pacharawan
    Shank, Lalida
    Jakmunee, Jaroon
    Watanesk, Ruangsri
    Watanesk, Surasak
    CHIANG MAI JOURNAL OF SCIENCE, 2017, 44 (04): : 1431 - 1440
  • [45] Carbon nanohorns/poly(glycine) modified glassy carbon electrode: Preparation, characterization and simultaneous electrochemical determination of uric acid, dopamine and ascorbic acid
    Zhang, Guangli
    He, Ping
    Feng, Wanru
    Ding, Shuangshuang
    Chen, Jingchao
    Li, Lian
    He, Huichao
    Zhang, Susu
    Dong, Faqin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 760 : 24 - 31
  • [46] Determination of L-DOPA at an optimized poly(caffeic acid) modified glassy carbon electrode
    Rohanifar, Ahmad
    Devasurendra, Amila M.
    Young, Joshua A.
    Kirchhoff, Jon R.
    ANALYTICAL METHODS, 2016, 8 (44) : 7891 - 7897
  • [47] Selective determination of uric acid in the presence of ascorbic acid at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode
    Tang, Hao
    Hu, Guang-zhi
    Jiang, Sheng-xiang
    Liu, Xia
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (12) : 2323 - 2328
  • [48] Poly(3-thiophenemalonic acid) Modified Glassy Carbon Electrode for Selective Determination of Dopamine and Urine Acid in the Presence of Ascorbic Acid
    Wan, Jia
    Xu, Guang-Ri
    Liu, Zhangsuo
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (12): : 12955 - 12962
  • [49] Selective determination of uric acid in the presence of ascorbic acid at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode
    Hao Tang
    Guang-zhi Hu
    Sheng-xiang Jiang
    Xia Liu
    Journal of Applied Electrochemistry, 2009, 39 : 2323 - 2328
  • [50] Simultaneous determination of ascorbic acid, dopamine and uric acid using poly(4-aminobutyric acid) modified glassy carbon electrode
    Zheng, Xinyu
    Zhou, Xuechou
    Ji, Xiaoyan
    Lin, Ruiyu
    Lin, Wenxiong