An amperometric biosensor based on poly(l-aspartic acid), nanodiamond particles, carbon nanofiber, and ascorbate oxidase-modified glassy carbon electrode for the determination ofl-ascorbic acid

被引:32
|
作者
Kacar, Ceren [1 ]
Erden, Pinar Esra [2 ]
机构
[1] Ankara Univ, Fac Sci, Dept Chem, TR-06100 Ankara, Turkey
[2] Ankara Haci Bayram Veli Univ, Polatli Fac Sci & Arts, Dept Chem, TR-06900 Ankara, Turkey
关键词
Amperometric biosensor; l-Ascorbic acid; Carbon nanofiber; Poly(l-aspartic acid); Nanodiamond; AGRICULTURAL APPLICATION; ELECTROCHEMICAL SENSOR; GRAPHITE ELECTRODE; L-LYSINE; COMPOSITE; NANOTUBES; IMMOBILIZATION; FABRICATION; NANOCOMPOSITE; NANOPARTICLES;
D O I
10.1007/s00216-020-02747-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An amperometricl-ascorbic acid biosensor utilizing ascorbate oxidase (AOx) immobilized onto poly(l-aspartic acid) (P(l-Asp)) film was fabricated on carbon nanofiber (CNF) and nanodiamond particle (ND)-modified glassy carbon electrode (GCE). Effects of AOx, ND, and CNF amounts were investigated by monitoring the response currents of the biosensor at different amounts of AOx, ND, and CNF. The electropolymerization step ofl-aspartic acid on CNF-ND/GCE surface was also optimized. Scanning electron microscopy (SEM), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) techniques were used to enlighten the modification steps of the biosensor. The effects of pH and applied potential were studied in detail to achieve the best analytical performance. Under optimized experimental conditions, the AOx/P(L-Asp)/ND-CNF/GCE biosensor showed a linear response tol-ascorbic acid in the range of 2.0 x 10(-7)-1.8 x 10(-3) M with a detection limit of 1.0 x 10(-7) M and sensitivity of 105.0 mu AmM-1 cm(-2). The novel biosensing platform showed good reproducibility and selectivity. The strong interaction between AOx and the P(l-Asp)/ND-CNF matrix was revealed by the high repeatability (3.4%) and good operational stability. The AOx/P(l-Asp)/ND-CNF/GCE biosensor was successfully applied to the determination ofl-ascorbic acid in vitamin C effervescent tablet and pharmaceutical powder containing ascorbic acid with good results, which makes it a promising approach for quantification ofl-ascorbic acid.
引用
收藏
页码:5315 / 5327
页数:13
相关论文
共 50 条
  • [31] Silver Doped Poly(L-valine) Modified Glassy Carbon Electrode for the Simultaneous Determination of Uric Acid, Ascorbic Acid and Dopamine
    Hu, Wenna
    Sun, Dengming
    Ma, Wei
    ELECTROANALYSIS, 2010, 22 (05) : 584 - 589
  • [32] An Amperometric Biosensor Based on Ascorbate Oxidase Immobilized in Poly(3,4-ethylenedioxythiophene)/Multi-Walled Carbon Nanotubes Composite Films for the Determination of l-Ascorbic Acid
    Ming Liu
    Yangping Wen
    Jingkun Xu
    Haohua He
    Dong Li
    Ruirui Yue
    Guodong Liu
    Analytical Sciences, 2011, 27 : 477 - 482
  • [33] An Amperometric Biosensor Based on Ascorbate Oxidase Immobilized in Poly(3,4-ethylenedioxythiophene)/Multi-Walled Carbon Nanotubes Composite Films for the Determination of L-Ascorbic Acid
    Liu, Ming
    Wen, Yangping
    Xu, Jingkun
    He, Haohua
    Li, Dong
    Yue, Ruirui
    Liu, Guodong
    ANALYTICAL SCIENCES, 2011, 27 (05) : 477 - 482
  • [34] Selective Determination of Dopamine and Uric Acid at Poly(acid red 176) Modified Glassy Carbon Electrode in the Presence of Ascorbic Acid
    Li, Xiao-bo
    Xu, Guang-ri
    Hu, Rui-yuan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (02): : 1920 - 1927
  • [35] Voltammetric determination of ascorbic acid with zinc oxide modified glassy carbon electrode
    Nadia Ait Ahmed
    Houa Hammache
    Marielle Eyraud
    Carine Chassigneux
    Florence Vacandio
    Philippe Knauth
    Laid Makhloufi
    Nour-eddine Gabouze
    Journal of the Iranian Chemical Society, 2019, 16 : 1957 - 1963
  • [36] Voltammetric determination of ascorbic acid with zinc oxide modified glassy carbon electrode
    Ahmed, Nadia Ait
    Hammache, Houa
    Eyraud, Marielle
    Chassigneux, Carine
    Vacandio, Florence
    Knauth, Philippe
    Makhloufi, Laid
    Gabouze, Nour-eddine
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2019, 16 (09) : 1957 - 1963
  • [37] Determination of dopamine in the presence of ascorbic acid using poly (acridine red) modified glassy carbon electrode
    Zhang, YZ
    Jin, GY
    Wang, YL
    Yang, ZS
    SENSORS, 2003, 3 (10): : 443 - 450
  • [38] Determination of epinephrine in the presence of ascorbic acid using poly (amidosulfonic red) modified glassy carbon electrode
    Jin, GY
    Zhang, YZ
    Yang, ZS
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (01) : 83 - 86
  • [39] Norepinephrine-modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid
    Zare, HR
    Memarzadeh, F
    Mazloum-Ardakani, M
    Namazian, M
    Golabi, SM
    ELECTROCHIMICA ACTA, 2005, 50 (16-17) : 3495 - 3502
  • [40] Electrochemical Determination of Ascorbic Acid Based on AgNPs/PVP-Modified Glassy Carbon Electrode
    Karaboduk, Kuddusi
    CHEMISTRYSELECT, 2019, 4 (20): : 6361 - 6369